is based on proven mico-machined silicon technology that offers high reliability,long-term stability
The Model DCT Transducer is designed for general industrial and commercial requirements offering excellent performance over a wide range of applications. It is based on proven mico-machined silicon technology that offers high reliability, long-term stability, and low cost relative to competing technologies. It combines precision pressure sensing with a rugged stainless steel construction that allows it to operate reliably under the most extreme environmental conditions.

The Model DCT Pressure Transducer is available in a variety of mounting and electrical options and pressure ranges from 6 PSI to as high as 5,000 PSI. It is fully digitally compensated for effects of pressure and temperature changes and calibrated to produce industry standard electrical outputs. The Model DCT accepts both unregulated and regulated excitation voltages and provides output signals such as 1-5VDC, 1-6VDC, 4-20mA, or millivolt.

The Model DCT is easy to install and maintain. No adapters are required, and there is no need for field calibration. It offers superior accuracy, below 0.25% span and below 1% over a wide compensated temperature range. Its design incorporates a stainless steel isolation diaphragm and 316 SS construction for use with most media types.

 
Features
  • .20% accuracy typical .3% worst
  • Excellent long term stability
  • Solid State / Industrial grade
  • Temperature compensated
  • Many ranges up to 5,000psi
  • mv, 4-20mA, 1-5VDC, 1-6VDC output
  • Vacuum and compound pressure ranges available
  • Low cost Low cost
 
SPECIFICATIONS

Pressure Range

Vacuum up to 500psig
Reference Accuracy ¡¾0.2% FS TYP, ¡¾-.3 FS MAX
(Consult factory for ranges below 15psi)
Total Error Band
(Includes temperature effects)
¡¾1% FS
1 Year Stability <0.25% FS
Outputs 1-5VDC

1-6VDC

10mv/v

4-20mA

Input Supply Voltage 9-30VDC

9-30VDC

10VDC Max.

11-30VDC

Load Limitation 50K¥Ø Min.

50K¥Ø Min.

 

500¥Ø Max.

Operating Temperature -40 to 80¡Æ C
Process Temperature -40 to 125¡Æ C
Compensated Temperature -25 to 75¡Æ C
Overpressure 2X FS or 750psig, whichever is less
Burst Pressure 3X FS or 750psig, whichever is less
Vibration 10G, 55-2,000 Hz.
Shock 30G
EMC Rated 3V/m (Requires "PE" option)
Process Wetted Material Brass, Borosilicate, Silicon, RTV, Epoxy
Electronics Housing Material 1/8-27 NPT., 1/4-19 NPT.
Electrical Connection Cable DIN Packard

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AM316147   DCTC0030PT021   Pressure Transducer 1/4 NPT 4-20mA, -14.7-30psi   Yes   550,800¡¡
AM316060   DCTG0006PT021   Pressure Transducer 1/4 NPT 4-20mA, 0-6psi   Yes   550,800¡¡
AM316030   DCTG0030PT021   Pressure Transducer 1/4 NPT 4-20mA, 0-30psi   Yes   550,800¡¡
AM316100   DCTG0100PT021   Pressure Transducer 1/4 NPT 4-20mA, 0-100psi   Yes   550,800¡¡
AM316300   DCTG0300PT021   Pressure Transducer 1/4 NPT 4-20mA, 0-300psi   Yes   550,800¡¡
AM316500   DCTG0500PT021   Pressure Transducer 1/4 NPT 4-20mA, 0-500psi   Yes   550,800¡¡
AM316502   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-1000 PSIS   Yes   594,000¡¡
AM316503   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-2000 PSIS   Yes   594,000¡¡
AM316504   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-3000 PSIS   Yes   594,000
AM316505   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-5000 PSIS   Yes   594,000
AM316506   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-30 PSIA   Yes   594,000
AM316507   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-60 PSIA   Yes   594,000
AM316508   DCTC0030PT021   PRESSURE TRANSDUCER 1/4 NPT 4-20mA, 0-100 PSIA   Yes   594,000¡¡
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ