The new Industrial IXLdp was designed for the measurement and control of very low pressure
The new Industrial IXLdp was designed for the measurement and control of very low pressure and flow in industrial and process plant environments. The Industrial IXLdp transmitter features a rugged NEMA 4X enclosure, built-in electrical terminal box isolated from the electronics and threaded process connections.

The IXLdp transmitter utilizes a state of the art variable capacitance sensor with a glass-clad silicon chip. The Si-Glas technology combines the inherent high sensitivity of a variable capacitance transducer with the repeatability of a micro-machined, single crystal silicon diaphragm.

The Si-Glas sensor is composed of sputtered metals and glass molecularly bonded to silicon. There are no epoxies or other organics in the sensor to contribute to drift or mechanical degradation over time. The silicon diaphragm withstands high overpressure as well as shock and vibration.

 
Applications
  • Precision Fan Tracking
  • Filter Monitoring
  • Operating Room Pressurization
  • Laboratory Fume Hood Control
  • Lab/Clean Room Pressurization
  • Precise Velocity Pressure Measurement
  • Laminar Flow Measurement
  • Furnace Draft Measurement
  • Oven Air Flow Control
  • Stack Gas Flow Measurement
  • Baghouse Monitoring
  • Combustion Air/Fuel Ratio Control
  • Leak Detection Hazardous Location Certifications
  • FM approval is optional Factory Mutual approvals intrinsically safe for use in: Class I, Div. 1, Groups A, B, C, D Class II, Div. 1, Groups E, F, G Class III, Div. 1, when wired in accordance with Dresser drawings 71B241 (1-3)
 
Features
  • Certified 0.25% & 0.50% Accuracy
  • High Overload Protection
  • NEMA 4X Metal Construction
  • Six Output Signals
  • Easy Installation
 
SPECIFICATIONS

Performance Specifications

Accuracy Class (70¡ÆF Ref.)
Standard ¡¾0.5% of F.S.
Optional ¡¾0.25% of F.S.
Accuracy: F.S. ¡¾0.5% ¡¾0.25%
Non-linearity
Terminal point ¡¾0.4 ¡¾0.2
Best straight line ¡¾0.3 ¡¾0.15
Hysteresis ¡¾0.02 ¡¾0.02
Non-repeatability ¡¾0.05 ¡¾0.03
Stability ¡¾0.5% F.S./year
Standard Ranges (Inches W.C.)
Unidirectional Ranges
Differential of Gage

0/0.1
0/50

0/2.0 0/10
0/0.25
0/100
0/2.5 0/15
0/0.50
0/150
0/3.0 0/20
0/1.0
0/200
0/5.0 0/25
Bidirectional Ranges
Compound or Vacuum
¡¾0.05 ¡¾2.5 ¡¾20.0
¡¾0.25 ¡¾5.0 ¡¾25.0
¡¾.50 ¡¾10.0 ¡¾50.0
¡¾1.0 ¡¾15.0 ¡¾100.0
Environmental Characteristics
Temperature Limits
Storage -40 to 210¡ÆF
Operating -20 to 185¡ÆF
Compensated 0 to 160¡ÆF
Thermal Coefficients
  0.5% Acc. 0.25% Acc.
Zero ¡¾0.02% F.S./¡ÆF ¡¾0.01% F.S./¡ÆF
Span ¡¾0.02% F.S./¡ÆF ¡¾0.01% F.S./¡ÆF
Functional Characteristics
Overpressure Limits
Proof pressure 15 psid
Burst differential pressure 50 psis
Maximum static (line) pressure 100 psis
Mounting Position Effect
1" W.C. and higher ¡Â0.1% F.S./g
0.25" up to 0.5" W.C. ¡Â0.5% F.S./g
0.1" W.C.  ¡Â0.8% F.S./g
Warm-up Time
Full specification 1 second
Response Time
Standard  250ms
Electrical Specifications
Output Signal Options
Current 4-20mA two wire current loop
Voltage      All voltage outputs are 3 wire
0-5 VDC
1-5 VDC
1-6 VDC
¡¾2.5 VDC
¡¾5 VDC
Power Supply Range
 12-36 VDC range without effect on output signal
Reverse Polarity Protected
Internal Zero and Span
 ¡¾10% F.S. Adjustment
Supply Current
 2.6mA typical for voltage output
Physical Characteristics
Enclosure
 NEMA 4X
300 series stainless steel

Process Connections

Two 1/4 NPT female
Electrical Two 1/2" female electrical
Connections conduit connections isolated from the electronics. Separate access cover for terminal connections
Media Clean, dry and non corrosive gas
 Not for Use on Liquids

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
AS910501   IX-3-FO2-42-ST-P1IW   Industrial Pressure Transmitter   Yes   1,587,600 
AS91502   IX-5-FO2-42-ST-P1IW   Industrial Pressure Transmitter   Yes   1,242,000 
AS910507   IX-3-FO2-15-ST-P5IW   Industrial Pressure Transmitter   Yes   1,458,000 
AS910508   IX-5-FO2-15-ST-P5IW   Industrial Pressure Transmitter   Yes   1,069,200 
AS910509   IX-3-FO2-42-ST-1IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910510   IX-5-FO2-42-ST-1IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910513   IX-3-FO2-42-ST-3IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910514   IX-5-FO2-42-ST-3IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910515   IX-3-FO2-15-ST-5IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910516   IX-5-FO2-15-ST-3IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910517   IX-3-FO2-42-ST-5IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910518   IX-5-FO2-42-ST-5IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910700   IX-3-FO2-42-ST-10IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910522   IX-5-FO2-42-ST-10IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910525   IX-3-FO2-42-ST-25IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910526   IX-5-FO2-42-ST-25IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910527   IX-3-FO2-15-ST-25IW   Industrial Pressure Transmitter   Yes   1,393,200 
AS910528   IX-5-FO2-15-ST-25IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910529   IX-3-FO2-42-ST-50IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910529   IX-3-FO2-42-ST-50IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910530   IX-3-FO2-42-ST-50IW   Industrial Pressure Transmitter   Yes   1,026,000 
AS910533   IX-3-F02-42-ST-100IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910535   IX-3-FO2-15-ST-100IW   Industrial Pressure Transmitter   Yes   1,414,800 
AS910536   IX-5-FO2-15-ST-100IW   Industrial Pressure Transmitter   Yes   1,026,000 
ML428271   24.75STS-3   OPTIONAL Process Power Pack 24Vdc-175mA FOR Industrial Differential / Low Pressure Transmitter   Yes   343,440

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ