ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > Àü±â ¹× Àü·ÂÃøÁ¤±â > TES

TES 3063 Power AC/DC Clamp Meter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
TES-3063/3064 Power AC/DC Clamp Meter

1 ¥Õ 2W, 1 ¥Õ 3W,3 ¥Õ 3W,3 ¥Õ 4W

  • RS-232 interface to talk with PC
  • 4 digits with dual display LCD
  • Amp / Voltage f requency measurement
  • Dual display KW+PF , KVA+PF , V+A
  • 4000 continuity point data logger , 25 point manual data logger
  • True power / apparent power / power factor measurement
  • True RMS. V , A , W , cap , lnd , phase indicator
  • MIN / MAX measurement
  • Peak hold detector
  • Dual display A+Hz , V+Hz
EN61010-1
600V Installation CAT III
Pollution Degree 2

¡¡

¡¡
True Power & Apparent power measurement
Input
Resolution
Accuracy
Frequency range
Overload protection
V<130V, A<150A
0.01
+/- (2%+5)
45Hz - 500Hz
600V/1100A
V>130V, A<150A
V<130V, A>150A
V>130V, A>150A
0.1
+/- (2%+1)
DCA
Range
Resolution
Accuracy
Overload protection
1000A
0.1A
+/- (1.5%rdg + 5dgts)
1100A
ACA
Range
Resolution
Accuracy
Frequency range
Overload protection
1000A
0.1A
+/- (1.5%rdg + 5dgts)
45Hz - 500Hz
1100A
‧Crest Factor: <4 for stated accuracy
DCV
Range
Resolution
Accuracy
Input Impedance
Overload protection
600V
0.1V
+/- (0.5%rdg + 5dgts)
1M ¥Ø
600V
ACV
Range
Resolution
Accuracy
Input Impedance
Frequency range
Overload rotection
600V
0.1V
+/- (0.5%rdg + 5dgts)
1M ¥Ø
45Hz - 500Hz
600Vms
‧Crest Factor: <3 for stated accuracy
Peak Indication
Range
Resolution
Accuracy
Overload protection
20A - 80A
0.1A
+/- (10%rdg + 10dgts)
1100A
80A - 1000A
+/- (6%rdg + 10dgts)
‧Peak Detect Acquisitions Time<=1ms
Peak Indication
Range
Resolution
Accuracy
Overload protection
20V - 80V
0.1V
+/- (10%rdg + 10dgts)
600Vrms
80V - 600V
+/- (6%rdg + 10dgts)
‧Peak Detect Acquisitions Time<=1ms
Audible continuity
Range
Continuity beeper
Open circuit voltage
Overload protection
<=0.050
<=3.2V
600Vrms
Resistance ( ¥Ø )
Range
Resolution
Accuracy
Frequency range
Overload protection
10K ¥Ø
1 ¥Ø
+/- (1%rdg + 5dgts)
<=3.2V
600Vrms
Diode test
Range
Resolution
Overload protection
0.001V
600Vrms
Frequency (Hz)
Range
Resolution
Accuracy
Voltage sensitivity
Overload protection
1KHz
0.1Hz
+/- (0.5%rdg + 5dgts)
10V or 10A
600V / 1100A
5KHz
1Hz
Optional Accessories: TES-3064 RS-232 Interface Adaptor / Software
GENERAL SPECIFICATIONS
Maximum Voltage between any
terminal and earth ground
600Vrms
Numerical Dual Display 4 digit liquid crystal display (LCD) maximum reding 9999.
Bargraph display 40 Segments.
Battery Life 30hr approx. (Alkaline)
Jaw Opening Diameter Cables f 46mm.
Operating Temperature and Humidity 0 ¡Éto 50 ¡É (32 ¢µ to 122 ¢µ ) R.H. < 80% non-condensing.
Storage Temperature and Humidity -10 ¡É to 60 ¡É (14 ¢µ to 140 ¢µ ) R.H. < 70% non-condensing.
Dimensions 260mm(L) x 93mm(W) x 45mm(H)
Weight Approx. 450g
Accessories Carrying Case, Test leads, One 9V Battery & Instruction manual

¡¡

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ