These metering systems offer durable, compact, high precision fluid measurement at a fraction of the price
These metering systems offer durable, compact, high precision fluid measurement at a fraction of the price of comparable systems. These housings are offered in Stainless Steel and PVDF for chemical applications, Brass and PVC for water applications. All have internal parts that are easily replaced. When paired with the microprocessor-based computers, information is clearly displayed on a large 6-digit display with an impressive 10:1 turndown ratio. The small, compact electronics package provides local indicators with signal output capabilities. Features can include automatic on and off, manual on, multiple totalizers, multiple-point calibration curves, signal output, rate of flow, total flow, or a combination of both. All features are easily accessed with two buttons. The six-digit, LCD display has a two-point floating decimal for totals from 0.01 to 999,999. Both factory and user calibration are available. Operating temperature range is +14¡Æ to +140¡ÆF. Optional remote mounting kit allows for greater fluid temperatures. All meters, except PVC versions, are FM approved as Intrinsically Safe Class I, Div I, all Groups.
 
SPECIFICATIONS

Pipe ID

Flowrange GPM
Accuracy % of read
% Repeatability
1/2"
1-10
¡¾2.0
¡¾0.1
3/4"
2-20
¡¾1.5
¡¾0.1
1"
5-50
¡¾1.5
¡¾0.1
1 1/2"
10-100
¡¾1.0
¡¾0.1
2"
20-200
¡¾1.0
¡¾0.1
Housing Materials
Max Pressure psi
Wetted Materials
Max Fluid Temp w/Remote Kit
Brass
300  
Brass, PVDF,
250¡ÆF
316 SS, Ceramic
Tungsten Carbide
Stainless Steel threaded
1500 
316 SS, PVDF, Ceramic, Tungsten Carbide
250¡ÆF
Stainless Steel 150# ANSI
285 
316 SS, PVDF, Ceramic, Tungsten Carbide
250¡ÆF
PVDF
150
PVDF, Ceramic
180¡ÆF
PVC
150
PVC, PVDF, Ceramic
140¡ÆF

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
GP20410   G2B05N09GMA   Digital Flowmeter, 1/2" Brass FNPT   Yes   1,090,800¡¡
GP20411   G2B07N09GMA   Digital Flowmeter, 3/4" Brass FNPT   Yes   1,118,880 
GP20412   G2B10N09GMA   Digital Flowmeter, 1" Brass FNPT   Yes   1,140,480 
GP20413   G2B15N09GMB   Digital Flowmeter, 1-1/2" Brass FNPT   Yes   1,572,480¡¡
GP20414   G2B20N09GMB   Digital Flowmeter, 2" Brass FNPT   Yes   1,900,800¡¡
GP20415   G2H05N09GMB   Digital Flowmeter, 1/2" Stainless Steel FNPT   Yes   1,248,480¡¡
GP20416   G2H07N09GMB   Digital Flowmeter, 3/4" Stainless Steel FNPT   Yes   1,270,080 
GP20417   G2H10N09GMB   Digital Flowmeter, 1" Stainless Steel FNPT   Yes   1,291,680¡¡
GP20418   G2H15N09GMB   Digital Flowmeter, 1-1/2" Stainless Steel FNPT   Yes   1,831,680¡¡
GP20419   G2H20N09GMB   Digital Flowmeter, 2" Stainless Steel FNPT   Yes   2,436,480¡¡
GP20420   G2P05N09GMA   Digital Flowmeter, 1/2" PVDF FNPT   Yes   1,280,880 
GP20421   G2P10N09GMA   Digital Flowmeter, 1" PVDF FNPT   Yes   1,298,160 
GP20422   G2C05N09GMA   Digital Flowmeter, 1/2" PVC FNPT   Yes   1,017,360¡¡
GP20423   G2C10N09GMA   Digital Flowmeter, 1" PVC FNPT   Yes   1,041,120 
GP20424   G2S10F09GMD   Digital Flowmeter, 1" Stainless Steel 150# ANSI   Yes   1,723,680 
GP20425   G2S15F09GMD   Digital Flowmeter, 1-1/2" Stainless Steel 150# ANSI   Yes   2,198,880¡¡
GP20426   G2S20F09GMD   Digital Flowmeter, 2" Stainless Steel 150# ANSI   Yes   2,717,280¡¡
GP20427   113275-1   FM Approved Remote Mounting Kit   Yes   449,280¡¡
Maintains FM Approval of meter and allows computer mounted display to be removed and located up to 100" from turbine for high temperature or display convenience. Comes with 10¡¯ of cable.¡¡
GP20428   125060-1   Pulse Access Module   Yes   168,480¡¡
Mounts to the back of the turbine and provides an open collector (transistor) pulse signal. 0-60 VDC power required.¡¡
GP20429   113435-1   Condition Signal Output Module   Yes   460,080 
Replaces the electronic display and provides an open collector (transistor) pulse signal. 9-35 VDC power required.¡¡
GP20430   125100-1   4-20 mA Output Module   Yes   609,120¡¡
Mounts to the back of the turbine and provides a loop powered current signal. Adjust the signal using the zero and span trimpots, the 4-20 mA or 0-5 volt output allows for long distance transmission.¡¡
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ