ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Flow À¯·®°è > Ultrasonic Flow

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
DY811902 Portable Ultrasonic Flow Meter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:DY811902
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Portable battery operated flowmeter.Self-prompting, menu driven programming
Features
  • Portable battery operated flowmeter
  • Self-prompting, menu driven programming
  • Digital filter with auto frequency tracking
  • Operates up to 8 hours on its internal battery
  • Closed pipe, non-invasive transducers
  • Quick and easy installation
  • Cost effective solution to difficult flow applications
  • Measures both clean liquids and those with suspended solids or entrained gases
 
Easy Operation
  • Lightweight, less than 16 lbs.
  • Operates with cover closed
  • Self-contained battery with charger
  • One hand transducer strap on
 
Auto damping
  • Auto adjusts damping to to flow rate change
  • Provides steady repeating at stabilized flow
  • Rapidly tracks significant flow change
  • Dynamic process tracking
 
Digital filtering; auto frequency tracking
  • Tracks and locks on desired frequency
  • Eliminates undesired error frequencies
  • Linearizes turbulent/unsymmetrical flows
  • Allows mounting transducers without straight pipe runs
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
DY811902   D902-A1NA-NN   ENHANCED PORTABLE ULTRASONIC FLOWMETER M3-902 D902-A1NA-NN   Yes   11,221,200

 

DY811910   T-903 D070-1004-001   SERIES 902 STD TEMP/STD PIPE TRANSDUCER T-903 D070-1004-001   Yes   1,933,200

 

DY811911   T-914 D040-0402-001   HIGH TEMP/STD PIPE TRANSDUCER   Yes   3,445,200 
DY811912   D010-0200-100   TRANSDUCER EXTENSION CABLE 20 FT   Yes   645,840 
DYRENT   RENTAL DY811902 (MO)   OPTIONAL ULTRASONIC FLOW METER RENTAL SPECIFY (MONTHLY) FOR Ultrasonic Flowmeter   Yes   3,240,000

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ