DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
| |
The instrument¡¯s built-in display and setpoint control eliminate the need for separate power supply |
Designed to control
the flow of non-corrosive gases, the Model 810C Mass-Trak mass flow
controller meets the same performance criteria as any industry-standard
flow controller... at half the price.
The instrument¡¯s
built-in display and setpoint control eliminate the need for separate
power supply and readout electronics, necessary on most MFCs. A
straight, large diameter sensor tube prevents clogging and
contamination, and its stable, fast response valve provides precise
one-step control of critical gas flows. You simply set it and forget it.
|
|
Features
|
- Utilizes
thermal sensing principle for mass flow measurements
- Electromagnetic
valve provides continuous control
- Complete
control system in one small package
- Replaces
obsolete rotameters
- NIST
traceable calibration ensures measurement accuracy
|
|
|
CAT
NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
SA677110 |
|
810M |
|
Mass Flow
Meter |
|
Yes |
|
1,069,200
|
Standard
configuration includes; 0-5 VDC and 4-20 mA linear output signals; 24
VDC input power; ¨ù " female NPT inlet/outlet fittings; Viton®
¡°O¡± rings; 15 pin D-connector and mating connector; calibrated for
any flow range from 0 to 20 SCCM up to 50 SLPM equivalent nitrogen flow;
1.5% FS accuracy; maximum temperature 122 degrees F; maximum pressure
150 psig |
SA677111 |
|
810C |
|
Mass Flow
Controller |
|
Yes |
|
1,890,000
|
Same
as above, but includes integral flow control valve. Standard model
requires 24 VDC regulated input power; switchable 0-5 VDC and 4-20 mA
command signal |
SA677112 |
|
DR |
|
OPTIONAL
3 1/2 digit display reading flow
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
SA677113 |
|
1 |
|
OPTIONAL
1/8 inch compression fitting (up to 15 SLPM)
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
SA677114 |
|
2 |
|
OPTIONAL
¨ù inch compression fitting
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
SA677115 |
|
MP |
|
OPTIONAL
Medium Pressure (40-100 psig)
FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
SA677116 |
|
LF |
|
OPTIONAL
Low flow calibration (0 to 20 SCCM full
scale flow range) FOR Gas Mass Flow Controller |
|
Yes |
|
Call
031-777-1588
|
SA677117 |
|
810-T8 |
|
OPTIONAL
110VAC power supply
FOR Gas Mass Flow Controller |
|
Yes |
|
129,600
|
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|