SA677110 Mass Flow Meter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:SA677110
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The instrument¡¯s built-in display and setpoint control eliminate the need for separate power supply
Designed to control the flow of non-corrosive gases, the Model 810C Mass-Trak mass flow controller meets the same performance criteria as any industry-standard flow controller... at half the price.

The instrument¡¯s built-in display and setpoint control eliminate the need for separate power supply and readout electronics, necessary on most MFCs. A straight, large diameter sensor tube prevents clogging and contamination, and its stable, fast response valve provides precise one-step control of critical gas flows. You simply set it and forget it.

 
Features
  • Utilizes thermal sensing principle for mass flow measurements
  • Electromagnetic valve provides continuous control
  • Complete control system in one small package
  • Replaces obsolete rotameters
  • NIST traceable calibration ensures measurement accuracy
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
SA677110   810M   Mass Flow Meter   Yes   1,069,200
Standard configuration includes; 0-5 VDC and 4-20 mA linear output signals; 24 VDC input power; ¨ù " female NPT inlet/outlet fittings; Viton® ¡°O¡± rings; 15 pin D-connector and mating connector; calibrated for any flow range from 0 to 20 SCCM up to 50 SLPM equivalent nitrogen flow; 1.5% FS accuracy; maximum temperature 122 degrees F; maximum pressure 150 psig
SA677111   810C   Mass Flow Controller   Yes   1,890,000
Same as above, but includes integral flow control valve. Standard model requires 24 VDC regulated input power; switchable 0-5 VDC and 4-20 mA command signal 
SA677112   DR   OPTIONAL 3 1/2 digit display reading flow FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677113   1   OPTIONAL 1/8 inch compression fitting (up to 15 SLPM) FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677114   2   OPTIONAL ¨ù inch compression fitting FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677115   MP   OPTIONAL Medium Pressure (40-100 psig) FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677116   LF   OPTIONAL Low flow calibration (0 to 20 SCCM full scale flow range) FOR Gas Mass Flow Controller   Yes   Call 031-777-1588 
SA677117   810-T8   OPTIONAL 110VAC power supply FOR Gas Mass Flow Controller   Yes   129,600
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ