The CAP ANALOG/4100 system is Capacitance Probe Level Transmitter - a true two wire DC powered system.
The CAP ANALOG/4100 system consists of an electronic amplifier mounted in a cast aluminum explosion proof housing. This housing normally is integrally mounted on the rear of the probe.

The CAP ANALOG/4100 system is Capacitance Probe Level Transmitter - a true two wire DC powered system.

Probes are manufactured in a variety of insulation materials and metals. The active length of the probe will vary subject to the specific application of that system. The probe usually is mounted in a vertical position. Normally the probe is threaded into the process vessel with a 3/4" NPT connection.

 
Features
  • Immune to product build-up — The CAP ANALOG/4100 system will tolerate heavy build-up of conductive materials without loss of calibration
  • Two Wire — True two wire circuit. Use ordinary twisted pair wire, 4 to 20mA DC Signal
  • Rugged — Totally solid state electronics mounted in an explosion proof cast aluminum housing, with fused polyester finish for enhanced corrosion resistance
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
DV724101   4100   Level transmitter   Yes   1,933,200
DV724102   THD   OPTIONAL 1/2" Heavy duty teflon¢ç probe, Assembly Solid Probe FOR Capacitance Continuous Level Probe   Yes   507,600

 

DV724103   ¡¡ ¡¡ OPTIONAL Solid rod per foot (20 ft. Max.) FOR Capacitance Continuous Level Probe   Yes   5,400

 

DV7241031   TF   OPTIONAL Flexible Probe FOR Capacitance Continuous Level Probe   Yes   918,000 
DV724104   KF   OPTIONAL Kynar¢ç (PVDF) Flexible Probe 1" NPT FOR Capacitance Continuous Level Probe   Yes   918,000

 

DV724105   ¡¡ ¡¡ OPTIONAL Flexible probe length per inch (150' max) FOR Capacitance Continuous Level Probe   Yes   3,672

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ