The large backlit graphic LCD displays measured conductivity, process temperature, etc.. |
The GLI Model E53 is full-featured and easy to use. The large backlit graphic LCD displays measured conductivity, process temperature, both analog output values, and status of the relays. The analyzer can be configured to measure conductivity, total dissolved solids (TDS), or concentration in percent. The E53 has multiple language capabilities, and exceeds U.S. and European standards for EMI and RFI.
The GLI 3700E-series electrodeless conductivity sensors are rugged and non-fouling. Since this style sensor has no electrodes, problems associated with contacting type electrodes, like polarization, oily fouling, process coating, and contamination, will not affect the performance of the electrodeless sensor. |
|
Analyzer |
Enclosure |
NEMA 4X; polycarbonate face panel, epoxy-coated high-quality cast aluminum case | |
Power Requirements |
90-130 VAC, 50/60 Hz or 180-260 VAC, 50/60 Hz | |
EMI/RFI Conformance |
Certified CE compliant as specified by EN 50081-1 for emissions and EN 50082-2 for immunity | |
Relays (tow or four) |
Electromechanical; SPDT (Form C) contacts; U.L. rated5A 115/230 VAC, 5A @ 30 VDC resistive | |
Analog Outputs |
Two isolated 0/4-20 mA. | |
Communications |
RS-232 standard, HART Protocol optional | |
Operation Temp. |
-4 to 140¢ªF (-20 to 60¢ªC) | |
Storage Temp. |
-22 to 158¢ªF (-30 to 70¢ªC) | |
|
Measuring Range |
From 0 to 200 uS/cm up to 0 to 2,000,000 uS/cm | |
Operating Temperature Range |
14 to 392¢ªF (-10 to 200¢ªC) | |
|
Polypropylene |
100 psi @ 212¢ª F (6.9 bar @ 100¢ªC) | |
PEEK |
200 psi @ 392¢ª F (13.8 bar @ 200¢ªC) | |
Temperature Compensator |
Pt 1000 RTD | |
Transmission Distance |
Up to 300 ft. (91 m) | |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
GL5321 |
|
E53A2A1N |
|
Electrodeless conductivity analyzer, with two relays |
|
Yes |
|
1,998,000 |
GL5341 |
|
E53A4A1N |
|
ELECTRODELESS CONDUC ANALYZER W/4 RELAYS |
|
Yes |
|
1,836,000 |
GL53211 |
|
E53A2B1N |
|
Electrodeless conductivity analyzer, with two relays and HART protocol |
|
Yes |
|
2,462,400 |
GL53411 |
|
E53A4B1N |
|
ELECTRODELESS CONDUC ANALYZER W/HART PROTO |
|
Yes |
|
2,624,400 |
GL37252 |
|
3725E2T |
|
POLYPROPYLENE ELECTRODLESS CON SENSOR |
|
Yes |
|
1,026,000 |
GL37272 |
|
3727E2T |
|
PEEK ELECTRODELESS CONDUCTIVITSENSOR |
|
Yes |
|
1,350,000 |
GL432 |
|
MH432G |
|
CPVC SENSOR MOUNT HDWE FOR IMMERSION |
|
Yes |
|
205,200 |
GL5383 |
|
MH538 M3NZ |
|
CPVC SENSOR MOUNTING HDWE FOR FLOW-THROUGH |
|
Yes |
|
162,000 |
| |
|
|
| |
|