DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
| |
100 days of protection with no maintenance costs—ideal for employees |
Features |
- 100 days of protection with no maintenance costs—ideal for employees and contractors for short-term work projects
- Maintenance free – no sensor or battery replacement/charging, no calibration, no downtime
- Small size (1.0 x 1.45 x 2.3 inches / 26 x 37 x 58 mm) and lightweight (1 oz. / 30 g)
- Full function self-test of: audible/visual alarms plus integrity of sensor, battery and circuitry
- Continuously ON – one button activation and test
- Provides ≈95 dB tone
- Confidence LCD display advises instrument is on and functioning
- Continuous, alphanumeric LCD shows detector life remaining, alarm setpoints and advises self-test status
|
| | SPECIFICATIONS
General |
Impact-resistant ABS enclosure |
EMI/RFI |
Complies with EMC Directive 89/336/EEC |
Battery |
Lithium, non-replaceable |
Sensor |
Electrochemical cell (temperature compensated) |
Warranty |
100 days from activation, plus 1 year shelf-life |
Model |
GasAlert100 H2S |
GasAlert100 CO |
Operational life |
100 days |
100 days |
Sensor range |
0-100 ppm |
0-300 ppm |
Low alarm level |
10 ppm |
35 ppm |
High alarm level |
15 ppm |
200 ppm |
Operating temperature |
-22 to +113 ¡ÆF |
+5 to +113 ¡ÆF |
|
-30 to +45 ¡ÆC |
-15 to +45 ¡ÆC |
Calibration |
Not required |
Not required |
Indicators and Alarms |
Visual gas alarm |
Flashing, wide-angled alarm lens with dual red LEDs plus ALARM LCD |
Readout audible gas alarm |
Pulsing siren ≈95 dB at 1 ft./0.3 m |
Other |
Low battery, failure alarm, self-test pass, and end of life (audible/visual) |
Life remaining |
Continuously displayed in days and then hours |
Two alarm levels |
LOW alarm / HIGH alarm |
Alarm setpoints |
High and low (displayed on demand in ppm) |
Self-test status |
Advises to "TEST" and that self-test was passed |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
BW21011 |
|
GA100-H |
|
100 day Hydrogen Sulfide (H2S) |
|
Yes |
|
321,840 |
BW21012 |
|
GA100-M |
|
100 day Carbon Monoxide (CO) Detector |
|
Yes |
|
321,840 | | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|