100 days of protection with no maintenance costs—ideal for employees
Features
  • 100 days of protection with no maintenance costs—ideal for employees and contractors for short-term work projects
  • Maintenance free – no sensor or battery replacement/charging, no calibration, no downtime
  • Small size (1.0 x 1.45 x 2.3 inches / 26 x 37 x 58 mm) and lightweight (1 oz. / 30 g)
  • Full function self-test of: audible/visual alarms plus integrity of sensor, battery and circuitry
  • Continuously ON – one button activation and test
  • Provides ≈95 dB tone
  • Confidence LCD display advises instrument is on and functioning
  • Continuous, alphanumeric LCD shows detector life remaining, alarm setpoints and advises self-test status
 
SPECIFICATIONS

General

Impact-resistant ABS enclosure
EMI/RFI Complies with EMC Directive 89/336/EEC
Battery Lithium, non-replaceable
Sensor Electrochemical cell (temperature compensated)
Warranty 100 days from activation, plus 1 year shelf-life
Model GasAlert100 H2S GasAlert100 CO
Operational life 100 days 100 days
Sensor range 0-100 ppm 0-300 ppm
Low alarm level 10 ppm 35 ppm
High alarm level 15 ppm 200 ppm
Operating temperature -22 to +113 ¡ÆF +5 to +113 ¡ÆF
  -30 to +45 ¡ÆC -15 to +45 ¡ÆC
Calibration Not required Not required
Indicators and Alarms
Visual gas alarm Flashing, wide-angled alarm lens with dual red LEDs plus ALARM LCD
Readout audible gas alarm Pulsing siren ≈95 dB at 1 ft./0.3 m
Other Low battery, failure alarm, self-test pass, and end of life (audible/visual)
Life remaining Continuously displayed in days and then hours
Two alarm levels LOW alarm / HIGH alarm
Alarm setpoints High and low (displayed on demand in ppm)
Self-test status Advises to "TEST" and that self-test was passed

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
BW21011   GA100-H   100 day Hydrogen Sulfide (H2S)   Yes   321,840
BW21012   GA100-M   100 day Carbon Monoxide (CO) Detector   Yes   321,840
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ