The Gas Alarm Clip provides two years of continuous maintenance-free operation from the day of activation.
The Gas Alarm Clip provides two years of continuous maintenance-free operation from the day of activation. Operated by an advanced microcontroller and electrochemical sensor, the unit is equipped with two levels of alarm, a full feature LCD status panel and high output audible/visual alarms.

Simply press the START/TEST button and the unit is ready for use. The life remaining is displayed in months, then days and then hours. The full function self-test verifies sensor, circuit and battery integrity and audible/visual alarms.

Alarm setpoints, peak alarm and the time elapsed since the peak alarm occurred are displayed on command. Generate a permanent record of gas alarm events encountered. Transmit stored event data to a cordless printer.

The rugged, compact unit is designed with the most advanced RFI protection available in industry today. Simply clip the instrument to your lapel, pocket, belt or hard hat for unequaled cost effective protection.
 
Features
  • Two years of protection with zero maintenance costs
  • Continuous, alphanumeric LCD shows detector life remaining, alarm setpoints and advises self-test status
  • Records and displays the peak alarm encountered and the time since the exposure occurred
  • Records and transmits gas alarm events encountered and the time elapsed since the event occurred
  • Two alarm levels (Low / High)
  • Provides ≈85 dB tone and bright LED indication on alarm
  • Internal vibrator alarm
  • Small size (1.1 x 2.0 x 3.2 inches / 28 x 50 x 81 mm) and lightweight (2.6 oz. / 73 g)
  • Maintenance free – no sensor or battery replacement, no calibration, no downtime
  • Full function self-test of: audible/visual alarms plus integrity of sensor, battery and circuitry
  • Continuously ON – one button activation, test and data transmission
  • Comes complete with pocket/belt clip, test cap and hose
  • Optional alligator and hard hat clips available
 
SPECIFICATIONS

Gas monitored

H2S CO SO2 O2
Sensor range 0 - 100 ppm 0 - 300 ppm 0 - 100 ppm 0 - 30.0% by vol.
Low alarm level 10 ppm 35 ppm 5 ppm 19.5 %
High alarm level 15 ppm 200 ppm 10 ppm 23.5 %
Operating Temperature -40 to +122 ¡ÆF/
-40 to +50 ¡ÆC
-22 to+122¡ÆF/
-30 to+50¡ÆC
-22 to +122 ¡ÆF/
-30 to +50 ¡ÆC

-4 to +122 ¡ÆF/
-20 to +50 ¡ÆC

Calibration Not required Not required Not required Self-calibrating
 Note 1: Special alarm settings available at no extra charge
Note 2: Internal vibrating option operates to -15 ¡ÆC / +5 ¡ÆF

SPECIFICATIONS

General

Impact-resistant ABS enclosure
Size 1.1 x 2.0 x 3.2 inches / 28 x 50 x 81 mm
Weight 2.6 oz. / 73 g
Operational life Two years
Humidity 5% to 95% RH (non-condensing)
EMI/RFI Complies with EMC Directive 89/336/EEC
Battery Lithium, non-replaceable
Warranty 2 years from activation plus 1 year shelf-life
Indicators and Alarms
Visual gas alarm Flashing, wide-angled alarm lens with dual red LEDs plus ALARM LCD readout
Audible gas alarm Pulsing siren ≈85 dB at 1 ft. / 0.3 m
Vibrator alarm Internal
Failure alarm Yes (audible/visual)
Self-test pass Yes (audible/visual)
Other Low battery and end of life (audible/visual)
Continuous LCD Display
Alphanumeric status panel LCD advises
Life remaining Continuously displayed in months, then days, then hours
Two alarm levels LOW alarm / HIGH alarm
Peak alarm exposure Continuously displayed in months, then days, then hours
Alarm setpoints High and low (displayed on demand in ppm or %)
Self-test status Records and displays peak alarm exposure, and time elapsed (up to 24 hrs.)
Tests High and low (displayed on demand in ppm or %) Advises to "TEST" and that self-test was passed
Full function self-test On-demand, as often as once every 20 hours and on activation
Battery Every two hours (auto)
Event Logging Records and transmits up to 10 gas alarm events
Event information Gas type, peak exposure level (ppm or %); alarm duration in minutes and seconds; time elapsed since the alarm occurred in days, hours and minutes
Transmission method Via infrared port to thermal printer

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
BW21001   GA100-H   100 day Hydrogen Sulfide (H<1sub>S)   Yes   540,000 
BW21002   GA24A-M-EL   Carbon Monoxide (CO) Detector with event logging   Yes   540,000 
BW21003   GA24A-S-EL   Sulfur Dioxide (SO<1sub>) Detector with event logging   Yes   637,200 
BW21004   GA24A-X-EL   Oxygen (O2) Detector with event logging   Yes   486,000 
BW21005   GA-HC-1   OPTIONAL Hard Hat Clip FOR Clip-On Gas Alarm   Yes   32,400 
BW45753   GA-AG-1   OPTIONAL ALLIGATOR CLIP FOR DETECTOR (non-conductive ABS) FOR Clip-On Gas Alarm   Yes   25,920

 

Please inquire for NIST Certification 
BW21007   GA-AG-2   OPTIONAL Alligator Clip (high tension metal) FOR Clip-On Gas Alarm   Yes   30,240 
BW21008   GA24-BALERT   OPTIONAL Concussion-proof boot with alligator clip FOR Clip-On Gas Alarm   Yes   43,200

 

BW21009   GPR-PRINTER   OPTIONAL Infrared Handheld Printer FOR Clip-On Gas Alarm   Yes   648,000 
BW21010   GACLIP-CD2   OPTIONAL GasAlertClip Training Video on DR-ROM FOR Clip-On Gas Alarm   Yes   6,480

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ