TL92501 Control Room Safety Oxygen Monitor
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:TL92501
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The Model 335 Oxygen Monitor is designed to accurately measure the oxygen concentration
The Model 335 Oxygen Monitor is designed to accurately measure the oxygen concentration in such applications as control rooms, closed atmospheres, critical breathing circuits, and other situations that require the fail safe monitoring of ambient air. The AC powered instrument is provided with a power fail back up system consisting of 2 NiCad battery packs maintained on a ¡°trickle¡± charge. Primary power interruption and sequential battery operation is signalled by illumination of a LOW AC panel light. Illumination LOW BATT light indicates that the batteries have been discharged to a dangerous level.

Two oxygen alarms can be set: CAUTION (20% oxygen) and DANGER (19.5% oxygen). Both alarm set points are factory set internally to prevent tampering or resetting by unauthorized personnel. When an insufficient oxygen concentration triggers an alarm, both the red panel light and an audible enunciator are energized. The alarms remain energized until the oxygen concentration has been elevated above the trigger point.

Calibration
A battery test push button is provided to visually check conditions of the batteries. Periodic calibration can be quickly and easily accomplished with the calibration adapter and a locking calibration control. The Model 335 uses a patented microfuel cell oxygen sensor which provides a linear output that is proportional to oxygen concentration. The sensor responds to even the slightest change in concentration within a few seconds. Its sealed electro chemical design is completely maintenance free. At the end of its useful life, the sensor is disposed of like a flashlight battery.

 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TL92501   335   CONTROL ROOM SAFETY OXYGEN MONITOR   Yes   3,996,000
TLB3   B3   OPTIONAL FUEL CELL FOR Control Room Oxygen Safety Monitor   Yes   231,120 
Please inquire for NIST Certification 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ