These monitors are single point detection instruments that accurately measure toxic gases and oxygen levels.
These monitors are single point detection instruments that accurately measure toxic gases and oxygen levels. Alarm lights on the front panel illuminate and an internal horn sounds when gas concentrations are exceeded.
 
Features
  • Large backlit LED
  • Smart Sensor technology
  • Linear 4-20mA output
  • AutoCal Calibration locally or from a distance
  • Internal push button alarm settings
  • Optional Remote digital control connection
  • Onboard relays for alarm points
 
SPECIFICATIONS
Measurement Range (Must specify at time of ordering)
Ammonia (NH3) 0 to 200ppm or 1000ppm
Carbon Monoxide (CO) 0 to 500ppm or 2000ppm
Chlorine (Cl2) 0 to 50ppm or 250ppm
Chlorine Dioxide (CIO2) 0 to 1.0ppm
Hydrogen (H2) 0 to 2000ppm or 0 to 4% volume
Hydrogen Chloride (HCL) 0 to 200ppm
Hydrogen Cyanide (HCN) 0 to 200ppm
Hydrogen Sulfide (H2S) 0 to 200ppm or 1000ppm
Nitrogen Dioxide (NO2) 0 to 50ppm or 200ppm
Oxygen (O2) 0 to 30% vol.
Sulfur Dioxide (SO2) 0 to 50ppm or 500ppm
Detection Principal Electrochemical
Response Time T90 <5 sec. (depending on gas)
Expected Sensor Life 2 years (depending on gas)
Display 4 digit LCD (EC36 backlit) with Power, Alarm and Fault LED's (EC36)
Weight and Dimensions 2 lbs.; 7.5 x 7.9 x 4.8 in. WxHxD (190 x 200 x 120 cm)
Power Supply 115V AC / 24V DC; 95 dba at one foot
Temperature Range  +5 to +115 ¡ÆF (-15 to +46 ¡ÆC)
Humidity Range 15 to 96% rh
Pressure Range 920 to 1080 hPa
Housing UL 94 HB polystyrene enclosure with clear polycarbonate lid
Housing Approvals IP 65

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
DN3701030   3701-030   Dynagard Fixed Single Gas Monitor for O2   Yes   2,041,200
DN3704500   3704-500   Dynagard Fixed Single Gas Monitor for CO   Yes   2,797,200
DN3704200   3704-200   Dynagard Fixed Single Gas Monitor for H2S   Yes   2,797,200
DN3708050   3708-050   Dynagard Fixed Single Gas Monitor for CI2   Yes   3,013,200
DN2350427   2350427   O2 Sensor   Yes   270,000
DN2350407   2350407   CO Sensor   Yes   442,800
DN2350420   2350420   H2S Sensor   Yes   442,800
DN2350409   2350409   CI2 Sensor   Yes   550,800
DN7771034   7771-034   OPTIONAL Calibration kit w/o gas FOR Auto Calibration Gas Monitor   Yes   529,200
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ