Combustion efficiency analyzer: measure O2 and CO. Calculate CO2, efficiency, excess air, and ratio. |
Combustion efficiency analyzer: measure O2 and CO. Calculate CO2, efficiency, excess air, and ratio. Will work with high efficiency furnaces, hot water heaters, and other combustible gas appliances. Combustible gas detector: set at 100-ppm sensitivity for natural gas. CO analyzer: measure 0-10,000 ppm CO. Differential thermometer: dual input K-type thermocouple temperature tester. Differential manometer: dual input differential manometer with 3 selectable units of measure (kPa, mBar, & inH20). |
|
Features |
- Easy to use
- Large, easy-to-read display
- Data log up to ten sets; timed logging 40 sets
- PC interface
- IR printer port
- Protective rubber boot included
- Three-year limited warranty and two year limited warranty on sensors
|
|
Applications |
- Perform combustion efficiency tests on combustible gas appliances
- Perform CO tests in residential and commercial buildings
- Test and setup pressure switches
- Check for proper gas pressures
- Check for natural gas or combustible leaks
- Measure temperature rise
- Verify thermostats are reading correctly
|
| | SPECIFICATIONS
Temperature Measurement |
Range –40¡Æ to 1,474¡Æ F (-40¡Æ to 800¡ÆC); resolution 1¡Æ F or C; accuracy (K) +/-0.3% or +/- 1¡Æ C whichever is greater |
Draft/Pressure Measurement |
-150 to +150 mBar, -15 to +15 kPa, -60 to +60 inH20; resolution 0.01 mBar; accuracy +/- 0.5% fsd |
Gross/Net Efficiency |
Range 0 to 100%; resolution 0.1%; calculated |
Oxygen (O2) Measurement |
Range 0 to 25%; resolution 0.1%; accuracy +/- 0.3% |
Carbon Monoxide (CO) Measurement |
Range 0 to 10,000 ppm; resolution 1 ppm; accuracy +/- 5 ppm or 5%, whichever is greater |
Carbon Dioxide (CO2) Measurement |
Range 0 to 25%; resolution 0.1%; calculated |
CO/CO2 Ratio |
Range 0 to 0.999; resolution 0.001; calculated |
Operating Temperature Range |
14¡Æ to 122¡Æ F (-10¡Æ to 50¡Æ C) |
Battery |
Rechargeable Ni-MH>6 hours |
Charger Input Voltage |
70 or 230 V, 50/60 Hz AC |
Fuels |
Natural Gas, LPG, Light Oil, Heavy Oil |
Display |
Backlit LCD |
Data Storage |
10 sets of readings |
Data Logging |
400 sets of readings on timed interval logging |
Time & Date |
24 hour Real Time Clock |
Dimensions |
200 mm x 90 mm x 60 mm |
Weight |
500 g |
Switch Off |
Failsafe |
Exhaust |
Safety spigot |
Conforms To |
BS7927 (and the draft BS7967) |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
TP7120 |
|
712 |
|
Flue Gas Analyzer |
|
Yes |
|
1,717,200 |
Includes protective boot, Flue probe with K-type thermocouple, probe, in-line filter, mini-pump protector, battery charger, exhaust spigot, and soft shoulder carrying case |
TP740 |
|
A740 |
|
IR printer |
|
Yes |
|
431,892 |
TP766 |
|
A766 |
|
AC charger adapter |
|
Yes |
|
64,692 |
TP769 |
|
A722 |
|
PC Software |
|
Yes |
|
161,892 |
TP767 |
|
A767 |
|
IRDA-R232 adapter |
|
Yes |
|
172,692 |
TP746 |
|
A746 |
|
Replacement paper (ten rolls) |
|
Yes |
|
21,492 |
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|