Engineered to give you more of everything you need for routine burner and boiler maintenance, etc.
Engineered to give you more of everything you need for routine burner and boiler maintenance, tuning, O2, CO2, CO and combustion efficiency checks. These units offer a sleek design and superior performance capabilities at breakthrough prices.
 
Features
  • Backlit display
  • Differential Pressure/Draft Testing
  • CO measurements up to 4,000 ppm
  • Immediate print out of readings on-site, with date and time and instrument serial number using wireless, infrared printer
  • New and improved carry case
  • Hands free operation with convenient magnetic backed, protective, SoftCase
  • Stores and prints separate Ambient CO reading
  • Four fuel choices: Natural gas, Propane, Light Oil, Heavy Oil
 
SPECIFICATIONS
Temperature Measurement
Measurement Range -40 to +1112 ¡ÆF
Accuracy ¡¾ 1 ¡ÆF
Resolution 0.1 ¡ÆF
Sensor Thermocouple type K (NiCr-Ni)
Draft/Pressure Measurement 
Measurement Range: ¡¾ 16" H2O and ¡¾ 80" H2O
Accuracy 0.01" H2O
Resolution 0.01" H2O
Net Efficiency 
Measurement Range 0 to 100%
Resolution 0.1%
O2 Measurement 
Measurement Range 0 to 21% by volume
Accuracy 0.2% vol. absolute
Resolution 0.1% vol
Response time T90 = < 45 seconds
CO2 Calculation 
Display Range 0 to CO2 max
Accuracy 0.2% vol.
Resolution 0.1% vol
Measurement Digital calculation from O2
CO Measurement: 
Display Range 0 to 4,000 ppm
Accuracy ¡¾ 5% of reading
Resolution 1 ppm
Response time T90 = < 45 seconds
Power Supply Optional 70 VAC source or Battery: 4 AA
Dimensions 8.5 x 3 x 2 inches
Weight Approximately 16 oz
Warranty 2 years
Operating Temperature 40 to 113 ¡ÆF
Storage Temperature -5 to 122 ¡ÆF
TT32515/6 
Stores 20 records with date and time
6 fuel choices including Coal and kerosene
 Recall stored records to display or print
 Recharge include NiCad batteries in the analyzer

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
TT32511   325M1   Analyzer, probe, vinyl case   Yes   1,509,840
TT32513   325M3   Analyzer, soft case, probe, carry case, includes IR printer   Yes   2,157,840 
TT32514   325M4   Analyzer, soft case, probe, carry case, includes IR printer and smoke tester   Yes   2,589,840

 

TT32515   325XL   Datalogging Analyzer, soft case, probe, carry case with NiCad batteries and power supply   Yes   2,797,200

 

TT32516   325XLP   Datalogging Analyzer, soft case, probe, carry case featuring 16 foot sampling house with NiCad batteries and power supply   Yes   3,531,600

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ