The DB-3060 delivers an economical solution to those users seeking a basic compliance tool.
DB-3060
The DB-3060 delivers an economical solution to those users seeking a basic compliance tool. Attach a pendant microphone and you have a noise dosimeter. Substitute a boom microphone and you¡¯ve converted your noise dosimeter to a power integrating sound level meter.
Simple and Accurate — The Data You Need At Your Fingertips With the press of a button, the DB-3060 provides all of the basic measurements you need to comply:
• Displays real-time sound level (SPL)
• Captures and displays the maximum sound level detected (Lmax)
• Captures and displays the peak sound level detected (Lpk)
• Calculates and displays average sound level (Lavg or Leq)
• Calculates and displays average sound level projected over 8 hours (TWA)
• Calculates and displays % of allowable dose incurred (Dose)
• Calculates and displays % of allowable dose expected over 8 hours (Projected Dose)
• Tracks and displays total time over 115 db

Easy Auto-Calibration
Like all DB-3000 series monitors, the DB-3060 field calibration is fast and easy. These monitors already know what sound level the acoustical calibrator outputs. Instantly initiate calibration from the DB-3060 keypad with the calibrator attached and let the noise monitor do the rest. Any adjustments that are necessary are automatically determined and made by the monitor.

DB-3080
• Comprehensive Time History & Amplitude
• Distribution Profiles
• Print Multiple Reports
• Automatically Starts & Stops Recording
• Survey Mode With Auto-Stop
• Advanced Software For Greater Productivity
In today¡¯s business climate, the value of effective and efficient tools to complete your work cannot be underrated. Metrosonics takes DB-3080 users to another level of productivity with MS-3080W Metrosoft¢ç for Windows¢ç. This comprehensive data management and reporting system offers the benefits of electronically capturing, storing, analyzing, manipulating, and reporting noise survey results. MS-3080W takes the integrity, defensibility and value of your noise studies to unparalleled levels.

Windows¢ç Compatibility
MS-3080W works seamlessly with your current Windows¢ç printer drivers to provide you with high quality charts and reports. You will produce professional looking reports never before possible by copying and pasting information directly from Metrosoft¢ç to other Windows¢ç programs such as Word, Excel and Powerpoint.

Powerful Charting Functions
Time History and Amplitude Distribution reports available from the DB-3080 directly to a printer may also be generated by MS-3080W in report or chart format to ease the analysis and comparison of test results. Metrosoft¡¯s¢ç tiling function enables you to perform on-screen, side-by-side comparisons of data. Zoom features allow enlarging plotted time history periods for more detailed examination of survey results at specific points in time. A scan line may be moved across time history charts to view the numeric data values represented by the chart graphics.

 
DB-3080 Features
  • Time History Profiler
  • Amplitude Distribution Profiler
  • Real Time Clock
  • For Each Time History Interval
  • Lav, Lmax
  • Lpeak
  • Time History Interval Length
  • Time History Ln¡¯s
  • Amplitude Distribution Ln¡¯s
  • Automatic Start/Stop Recording
  • Outputs Reports Directly to Printer
  • Transfers Data to PC
 
DB Series Features
  • Noise Dosimeter
  • Integrating Sound Level Meter
  • Peak Sound Level Meter
  • Recorded Statistics For Entire Test: Lav, Leq, Lmax, Lpeak, TWA, Dose, Projected Dose, Total Time Above Ceiling, User Selectable Criteria, Weighting (A or C), Response Rate (Fast or Slow), Exchange Rate (3, 4, 5 or 6 db)
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE
QS139350   DB-3060-MK   NOISE DOSIMETER KIT: WINDSCRN CL-304 CAL/CASE   Yes   3,196,800
QS139351   DB-3080-MK   PROFILE NOISE DOSIMETER KIT   Yes   4,600,800
QS139352   MS3080-MK   OPTIONAL WINDOWS SOFTWARE FOR DB-3080 FOR Noise Dosimeter / Profiler   Yes   1,077,840

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ