The 53100 series counters use real-time digital signal processing to analyze data |
The 53100 series counters use real-time digital signal processing to analyze data while simultaneously taking new readings. So while other counters are stuck in processing dead time, these counters have already moved on to the next measurement. And with continuous HP-IB data transfer rates of more than 200 measurements per second, you¡¯ll get the job done in a hurry.
Automated limit tests, instant recall of test setups and one-button access to the features you need most simplify your work. Plus, you can perform statistics on all measurements and simultaneously measure and track average, min/max and standard deviation. |
|
Features |
- Resolution of 10 or 12 digits/second; frequency ranges up to 3 GHz
- Versatile test and analysis features help you extract information from your measurement data
- Choice of three models to fit your needs and budget
|
| | SPECIFICATIONS
|
53131A |
53132A |
53181A |
Measurements |
Frequency, frequency ratio, time interval, period, rise/fall time, positive/negative pulse width, duty cycle, phase (CH 1 to CH 2), totalize, peak voltage, time interval average, time interval delay |
Frequency, frequency ratio (with optional CH 2),period, peak voltage |
Analysis |
Automatic limit testing, math (scale and offset), statistics (minimum, maximum, mean, standard deviation). Statistics available on all measurements or only measurements that fall within limits. |
Measurement characteristic |
Frequency range |
CH 1 & 2: dc–225 MHz |
CH 1 & 2: dc–225 MHz |
CH 1: dc–225 MHz |
Frequency resolution |
10 digits/s |
12 digits/s |
10 digits/s |
Measurement speed |
Up to 200 meas/s |
Up to 200 meas/s |
Up to 200 meas/s |
Time interval resolution (LSD) |
500 ps |
150 ps |
NA |
Input conditioning |
(Independently selectable on CH 1 & 2) |
(Independently selectable on CH 1 & 2) |
(Selectable on CH 1) |
Impedance, coupling |
1 M¥Ø or 50 ¥Ø, ac or dc |
1 M¥Ø or 50 ¥Ø, ac or dc |
1 M¥Ø or 50 ¥Ø, ac or dc |
Low pass filter |
100 kHz, switchable |
100 kHz, switchable |
100 kHz, switchable |
Attenuation |
x1 or x10 |
x1 or x10 |
x1 or x10 |
External timebase |
reference input |
1, 5, 10 MHz |
10 MHz |
1, 5, 10 MHz |
Trigger |
CH 1 & 2 |
CH 1 & 2 |
CH 1 |
Trigger on rising/falling edge; set level by percent of signal level or absolute voltage; set sensitivity to LOW, MED, or HIGH |
Gating and arming |
Auto, manual (set gate time or number of digits of resolution); external; delay |
Interfaces |
Standard HP-IB (IEEE 488.1 and 488.2) with SCPI-compatible language; talk only RS-232 |
Power |
90–132 Vac; 45–66 Hz or 360–440 Hz/198–264 Vac; 45–66 Hz |
Net weight |
3 kg (6.5 lbs) |
Size |
103.6 mm H x 254.4 mm W x 374 mm D (4.1 x 10.0 x 14.8 in) |
Warranty |
3 years |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
53131A |
|
53131A |
|
10 digits per second Universal counter |
|
Yes |
|
4,430,160 |
53131A/030 |
|
53131A/030 |
|
3 GHz Channel 3 with BNC connector (Channel 2 on HP53181A) |
|
Yes |
|
6,657,120 |
53132A |
|
53132A |
|
12 digits per second Universal counter |
|
Yes |
|
6,875,280 |
53132A/010 |
|
53132A/010 |
|
High stability timebase |
|
Yes |
|
9,100,080 |
53132A/030 |
|
53132A/030 |
|
3GHz Channel 3 with BNC connector |
|
Yes |
|
9,102,240 |
53181A |
|
53181A |
|
10 digits per second Universal counter |
|
Yes |
|
3,859,920 |
HP53181A/015 |
|
53181A/015 |
|
1.5GHz Channel 2 with BNC connector |
|
Yes |
|
5,110,560 |
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|