Portable, compact unit – plugs into standard US 120V outlets, Simple operation: Plug in, Record etc.
Features
  • Portable, compact unit – plugs into standard US 120V outlets
  • Simple operation: Plug in, Record, Download and Read
  • Measures & stores electrical parameters: V, A, Hz and more
  • Measures and stores power parameters: W, VA, Var, Demand, Peak Demand and more
  • Measures and stores power quality parameters: Harmonics, THD (rms and fundamental), K-Factor & more
  • Automatically captures worst-case Surge, Sag & THD waveforms for voltage & current
  • Stores 100 worst case surge & sag events including time, date & duration
  • High accuracy & resolution: 128 samples/cycle, 16 bit resolution
  • LEDs indicate mode of operation
  • Records up to 12 data channels
  • Powered from voltage input channel
  • Battery backup data integrity during power outages for up to 1 year. Configuration in non-volatile memory
  • Optically isolated RS-232 output for direct connection to a PC
  • EN 1010, 150V, Cat. III
  • Includes DataView¢ç Lite Analysis and Reporting Software DataView¢ç Lite and Professional Data Analysis & Reporting Software
 
Software Features
  • Display and analyze data on your PC
  • Configure all data logger functions and parameters from your PC including sample rate, recording length, channel configuration & more
  • Customize frames, templates & reports to your exact needs
  • Display real time data on your PC & download previously recorded data
  • Create & store a complete library of configurations that can be uploaded to the logger as needed
  • Zoom in and out and pan through sections of the graph to analyze the data
  • Display waveforms, trend graphs, harmonic spectrums and text summaries
  • Display surge and sag events in high-resolution waveforms and as tabular listings
 
SPECIFICATIONS

Models

AE212501

AE212502

AE212503

AE212504

(Memory)

(128KB)

(1MB)

(128KB)

(1MB)

Electrical Specifications
Measurements

True RMS measurement. 128 samples are simultaneously taken for voltage and current channel

Voltage
Range

0 to 140V

Resolution

0.1V

Accuracy

¡¾(0.3% of Reading + 0.3V)

Current
Range

0 to 15A (70A peak maximum)

Resolution

0.01A

Accuracy

¡¾(0.5% of Reading + 0.03A) @ 0.75A to 15A ¡¾0.30A @ < 0.75A

Frequency (Hz)
Range

45 to 65Hz

Resolution

0.01Hz

Accuracy

0.1Hz

Harmonics
Range

Up to 50th for both Voltage & Current

Resolution

0.1V for Voltage & 0.1A for Current

Power - Watt/ VA/Var
Range

0 to 2.1K Watt or VA or Var

Resolution

0.1W, 0.1VA, 0.1Var

Accuracy

¡¾(2.0% of Reading + 4x), where x is Watt or VA or Var

Power & Power Factor
Resolution

0.01

Accuracy

¡¾0.03% @ PF/DPF = 1

Programmable Parameters
 

V, A, Hz, Odd & Even Harmonics( V & A), W, VA, Var, THD (V & A), PF, DF, K-Factor

Demand

VA, W (10/15/30 minutes or user-definable)

Peak Demand

Over demand period

Voltage Sag/Surge

User-definable magnitude

Input
Input Channels

1 Voltage/1 Current

Sample Rate

128 per cycle per channel

Recording
Storage Rate

125ms to 7 days

Recording Session Length

15 minutes to 8 weeks (user programmable)

Total Memory

128KB

1MB

128KB

1MB

Date and Time

MM/DD/YY hh/mm/ss.sss

Surge & Sag and
THD Waveform
Storage
(worst case)

5
THD Waveform

20
THD Waveform

5
THD Waveform

20
THD Waveform


CAT NO. MODEL DEscRIPTION AVAIL PRICE
AE212501   PQL 100   Power Quality Logger (128KB storage)   Yes   1,717,200
AE212502   PQL 120   Power Quality Logger (128KB storage)   Yes   1,717,200
AE212503   PQL 100   Power Quality Logger (w/optional 1MB storage)   Yes   1,933,200
AE212504   PQL 120   Power Quality Logger (w/optional 1MB storage)   Yes   1,933,200
AE211902   ¡¡ ¡¡ OPTIONAL Soft Carrying Case FOR Power Quality Loggers   Yes   32,400
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ