These Clamp-On Power Meters are lightweight and easy to use.
These Clamp-On Power Meters are lightweight and easy to use. They offer the latest technology in power quality monitoring and analysis. A large LCD screen displays menu graphics and various power parameters such as voltage (VRMS), current (ARMS), active power (W), reactive power (VAR), and frequency (Hz). The YK1402 and YK1404 have an internal 1 MB memory that can log and store measurements for up to 1,000 hours (in 1 minute intervals. The YK1405 and YK1406 are compatible with 128MB flash memory cards which means that 1 year of data can be stored at 30 minute intervals. Data can be viewed in four (4) different modes: instant mode, demand mode, electric energy mode, and harmonic mode. Measured parameters include Power Factor and Phase angle in addition to those listed above.

For harmonic analysis, the 1st through 13th order harmonics can be displayed in an easy-to-understand bar graph format or as numeric values. The carrying case lets you carry the current and voltage probes without disconnecting them from the unit. And there is plenty of room left over for accessories.
 
Features for YK1402 & YK1404
  • Graphical LCD Screen
  • Store 1000 hours of data via 1 MB internal memory
  • Connectors accept 4 current clamps
  • Measure loads on two (2) power systems
  • Measure and View Harmonics
 
Features for YK1405 & YK1406
  • Graphical Backlit LCD Screen
  • Measure from 5 – 3000 Amps AC (using clamps)
  • Measure up to 1 year of data in 30-minute intervals
  • Save data to PC via RS-232 or RS-485
  • Compact Design (4.6" x 6.3" x 2")
  • YK1405: (1P2W, 1P3W & 3P3W);
    YK1406: (1P2W, 1P3W, 3P3W & 3P4W)
 
SPECIFICATIONS – YK1402 and YK1404
Temperature and Humidity
Operating 5 to 40¡ÆC, 35 to 80% RH
Power Adapter, 100-240 VAC, 50/60 Hz. (included)
Battery  NiMH Battery Pack — 7 hours run time
AA (6) Alkaline — 3 hours run time (included)
Terminals
Voltage Input 4 Banana Type
Current Input 4 Banana Type
External Control 2 H/L Screwless Terminals
Event Input 2 H/L Screwless Terminals
D/A Output 2 H/L Screwless Terminals
Dimensions 206 (W) x 65 (H) x 184 (D) mm
Weight 1.2 kg approximately

SPECIFICATIONS – YK1405 and YK1406
Voltage 0 – 150/300/450 V AC (+ 0.3% rdg + 0.2% rng)
Current/Active Power 0 – 700 amps + 0.8 rdg + 0.4% mg)
Frequency 45 – 65 Hz + (0.1% rdg + 1 digit)
Power + (0.5% rdg + 0.4% mg + 1V to 700 amps)
Sampling Rates 1/2/5/10/15/30 seconds; 1/2/5/10/15/30 minutes; 1 hour

CAT NO. MODEL DEscRIPTION AVAIL PRICE
YK1402   CW140D
/C2/PM1
  Clamp-On Power Meter with (4) 200A, current clamps, case and NIMH battery pack   Yes   6,486,480

 

YK1404   CW140D
/C4/PM1
  Clamp-On Power Meter with (4) 500A, current clamps, case and NIMH battery pack   Yes   6,819,120

 

YK1405   1201   Clamp-On Power Meter 1P2W, 1P3W & 3P3W (must select clamps from accessories)   Yes   2,203,200

 

YK1406   1202   Clamp-On Power Meter 1P2W, 1P3W & 3P3W (must select clamps from accessories)   Yes   2,484,000

 

YK96030   960-30   OPTIONAL Clamp-On Probe 200 A AC/600V FOR Yokogawa Clamp-On Power Meter   Yes   496,800

 

YK96031   960-31   OPTIONAL Clamp-On Probe 500A AC/600V FOR Yokogawa Clamp-On Power Meter   Yes   550,800

 

YK96032   960-32   OPTIONAL Clamp-On Probe 700A AC/600V FOR Yokogawa Clamp-On Power Meter   Yes   624,240

 

YK96033   960-33   OPTIONAL Clamp-On Probe 50A AC/300V FOR Yokogawa Clamp-On Power Meter   Yes   453,600

 

YK96034   960-34   OPTIONAL Clamp-On Probe 1000A AC/600V FOR Yokogawa Clamp-On Power Meter   Yes   896,400

 

YK96035   960-35   OPTIONAL Clamp-On Probe 300A/3000A AC/300V FOR Yokogawa Clamp-On Power Meter   Yes   1,121,040

 

YK93020   930-20   OPTIONAL Carrying Case (CW140 Series) FOR Yokogawa Clamp-On Power Meter   Yes   518,400

 

YK366969   366969   OPTIONAL AC Adapter with Power Cord (CW140) FOR Yokogawa Clamp-On Power Meter   Yes   216,000

 

YK94004   940-04   OPTIONAL NiMH Battery Pack FOR Yokogawa Clamp-On Power Meter   Yes   388,800
YK94006   940-06   OPTIONAL AC Adapter for Printer (Europe) FOR Yokogawa Clamp-On Power Meter   Yes   216,000

 

YK97007   970-07   OPTIONAL AC Adapter for Printer (US) FOR Yokogawa Clamp-On Power Meter   Yes   216,000

 

YK97080   970-80   OPTIONAL Thermal Printer Paper FOR Yokogawa Clamp-On Power Meter   Yes   129,600

 

YK91007   910-10   OPTIONAL Voltage Probe FOR Yokogawa Clamp-On Power Meter   Yes   64,800
YK9017   B9017VD   OPTIONAL RS232 Cable (to PC) FOR Yokogawa Clamp-On Power Meter   Yes   108,000
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ