The Megger BM11D and BM21 5 kV Insulation Resistance Testers are portable, battery-powered
The Megger BM11D and BM21 5 kV Insulation Resistance Testers are portable, battery-powered, high-voltage instruments that use the latest electronic design and technology. The instruments have user-friendly keypads with push-buttons to select test voltages of 500, 1000, 2500, and 5000 V dc. In addition to the standard test voltages, a variable voltage feature on the BM21 selects test voltages between 25 and 5000 V dc in 25-V steps.
 
Features
  • Analog/digital display
  • Multiple test voltages
  • Integral timer
  • Automatic discharge of equipment under test
  • Comprehensive battery state indicator
 
Applications
  • High-voltage power cables
  • Large motor/generator windings
  • Line and substation transformers
  • High-voltage buses
 
SPECIFICATIONS
 

MG817004

MG817005

Nominal Test Voltage (dc) 500, 1000, 2500, 5000 V 500, 1000, 2500, 5000 V; plus 25 - 5000 V in 25-V steps
Accuracy at 68¡ÆF (20¡ÆC)
¡¾5% on 100 m¥Ø load
Insulation Resistance Range
Digital 10 k¥Ø to 50 G¥Ø @ 500 V 10 k¥Ø to 500 G¥Ø @ 500 V
10 k¥Ø to 100 G¥Ø @ 1000 V 10 k¥Ø to 1 T¥Ø @ 1000 V
10 k¥Ø to 250 G¥Ø @ 2500 V 10 k¥Ø to 2.5 T¥Ø @ 2500 V
10 k¥Ø to 500 G¥Ø @ 5 kV 10 k¥Ø to 5 T¥Ø @ 5 kV
Analog 100 k¥Ø to 1 T¥Ø @ all voltages 100 k¥Ø to 1 T¥Ø @ all voltages
Accuracy at 68¡ÆF (20¡ÆC) ¡¾5% of reading 1 M¥Ø to 100 G¥Ø @ 5 kV ¡¾5% of reading 1 M¥Ø to 1 T¥Ø @ 5 kV
Voltage Range 50 to 1000 V dc or ac 50 to 1000 V dc or ac (0 to 5000 V dc when testing)
Accuracy at 68¡ÆF (20¡ÆC) ¡¾5%, ¡¾1 V  
Leakage Current Measurement None 0.01 nA to 999 ¥ìA; Accuracy ¡¾5% ¡¾0.2 nA
Capacitance Measurement None 0.01 to 10.0 ¥ìF
Timer Automatic; 0 to 60 minutes User selectable; 0 to 90 minutes
Short Circuit Current
2 mA nominal
Display
Analog/digital
Interference Rejection
1 mA r.m.s. per kV to a maximum 2 mA
Power Supply Two rechargeable, sealed lead-acid batteries (12 V, 2 Ah) Battery Life: Typically 8 hours continuous, 16 hr charge time
Dimensions/Weight 6 H x 10 W x 14 D in. (152 H x 250 W x 350 D mm)/13 lb (5.6 kg) approximate

CAT NO. MODEL DEscRIPTION AVAIL PRICE
MG817004   BM11D   5kV INSULATION RESISTANCE TESTER   Yes   7,989,840
Includes three 10++ test leads, carrying case, test record cards, charging cord and instruction manual.
MG817005   BM21   5kV INSULATION RESIST. TESTER W/VARIABLE TEST VOLT.   Yes   8,532,000 
Includes three 10++ test leads, carrying case, test record cards, charging cord and instruction manual.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ