Includes zip-up carry case, 1set test leads including prods and clips and operating instruction book.
Includes zip-up carry case, 1set test leads including prods and clips and operating instruction book.
 
Features
  • Suitable for testing to the IEE Wiring Regulations
  • Complies with the requirements of BS 7671, HD 384 and IEC 364
  • Combined insulation and continuity testing
  • Insulation testing at 500 V d.c. to the VDE 0413 Part 1
  • 3 Year Warranty
 
SPECIFICATIONS

Model

BD210800

BD210801

Insulation Test Voltage Ranges
500 V d.c.

500 V d.c.

Insulation Resistance Range
0 to 200 MW

0 to 200 MW

Resistance Range

0 to 1 MW

Continuity Ranges
0 to 200 W

0 to 200 W

 
0 to 2 W

0 to 2 W

Voltage Range
0 to 600 V a.c.

Terminal Voltage Insulation Resistance Range
<600 V (>500V at 0.5 M¥Ø)

<600 V >500V at 0.5 M¥Ø)

Terminal Voltage Resistance Range

53 V

Terminal Voltage Continuity Ranges
0.76 V

0.76 V

 
4.7 V

4.7 V

Terminal Current Insulation Resistance Range
1.6 mA

1.6 mA

Terminal Current Resistance Range

325 ¥ìA

Terminal Current Continuity Ranges
12.3 mA

12.3 mA

 
210 mA

210 mA

Accuracy (at 20¡ÆC) [2.5% of scale length on all ranges (i.e., ¡¾1.9 mm (0.075 in.) on insulation resistance range]
Movement
250 ¥ìA full scale deflection

250 ¥ìA full scale deflection

Voltmeter Input Impedance
330 k¥Ø

Power Supply Single 9 volt battery, IEC 6 LR61 type
Current Consumption 70 mA max. on insulation range, 40 mA max. on resistance range, 220 mA max. on 2¥Ø range
Battery Life More than 1800 5 second operations on 2¥Ø range
Safety The instruments will, in general, meet the requirements of the IEC 1010-1 (1990) safety specification.
Safety Class II, Flash test to 4 kV peak impulse. Phase-to-Phase voltages not exceeding 500V a.c.
Weight/Dimensions 485 g (1 lb approx)/175 H x 95 W x 57 D mm (6.9 H x 3.75 W x 2.25 D in. approx)

CAT NO. MODEL DEscRIPTION AVAIL PRICE
BD210800   BM100/4   Insulation and Continuity Tester   Yes   1,069,200
BD210801   BM101/4   Insulation and Continuity Tester   Yes   1,004,400
BD1210171   6420-030   OPTIONAL Synthetic test and carry case FOR Analog Insulation and Continuity Testers   Yes   259,200

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ