DC testing is popular because the equipment is more compact
DC testing is popular because the equipment is more compact and lighter in weight than comparable AC equipment and is also generally less expensive. We offer a line of conservatively designed and ruggedly built portable DC Hipots for use in testing electrical switchgear, cables, motors, generators and protective equipment.

The DC Hipots offered are suitable for lab or field use and are especially helpful when it is necessary to determine the adequacy of newly installed insulation or to determine when corrective steps are necessary to return equipment to a safe operating condition. The results of DC tests are also helpful in predicting the useful life of insulation and in establishing a maintenance inspection program to reduce failures in service and extend equipment life.
 
Design and Safety Features
  • Continuously adjustable output
  • Negative output, positive ground
  • Guard circuit for stray leakage current bypass
  • Three range voltmeter
  • Four range current meter
  • Zero start interlock
  • Control Power On switch with indicator
  • HV ON pushbutton with indicator
  • External interlock provision
  • Surge and transient protection
  • Rugged impact/corrosion resistant fiberglass cases with carrying handles and cable storage
  • 6 ft. input cord (three wire)
  • 20-foot test leads (3) with clips and boots
  • 25 foot interconnect cable
 
SPECIFICATIONS

Model

PX299115 PX299116 PX299117 PX299118
Input*
Voltage   120/220 VAC, 50/60 Hz   ¡¡
Current 2/1A 3/1.5A 5/2.5A 6/3A
Output
Voltage 0-30KV 0-70KV 0-100 KV 0-120KV
Current 5mA 5mA 5mA 5mA
Ripple   <2.5% peak-to-peak   ¡¡
Polarity   negative, positive ground   ¡¡
Duty Cycle   1 hour on / 1 hour off   ¡¡
Meters
Voltage ranges 0-6/12/30 0-14/35/70 0-25/50/100 0-30/60/120
Current ranges   0-50/50/500/5000 micro-amps   ¡¡
Type   41/2 in square, analog   ¡¡
Accuracy   ¡¾2% FS   ¡¡
Dimensions / Weights
  PX299115 PX299116 PX299117
Dimensions 21" W x 17" D x 13" H 23" W x 21" D x 16" H
(533 mm) (432 mm) (330 mm) (584 mm) (533 mm) (406 mm)
Weight* 53 lbs. (24 kg) 80 lbs. (36 kg) 106 lbs. (48 Kg)
 
 PX299118
Control Module 21" (533 mm) W x 17" (432 mm) D x 13" (30 mm) H33 lbs. (15 kg)
HV Module 17.25" (438 mm) W x 12" (305 mm) D x 22" (559 mm) H111 lbs. (50.4 kg)
 *Note for 220 VAC, add 10 lbs. (4.5 kg) to PX299116, PX299117 and PX299118 controls; 4 lbs. (1.8 kg) to PX299115

CAT NO. MODEL DEscRIPTION AVAIL PRICE
PX299115   430-5   PORTABLE DC HIPOT 30KV   Yes   8,100,000
PX299116   470-5   PORTABLE DC HIPOT TESTER 70KV   Yes   11,340,000
PX299117   4100-5   Portable DC Hipot 100KV   Yes   11,988,000
PX299118   4120-5   PORTABLE DC HIPOT TESTER 120KV   Yes   14,040,000
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ