ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Àü±â°èÃø±â Electrical > Àü·ÂºÐ¼®±â

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
PX299640 40kV AC Hipot
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:PX299640
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
High accuracy ¡¾1% FS, Ruggedly constructed cases for years of field use, Lightweight portability
• Now offering a premier line of 40, 50, and 60 kV models, providing test voltages for a wide range of electrical equipment
• Featuring 3 1/2 digit, digital LCD display output voltmeter and currentmeter for easy reading even in direct sunlight
• High accuracy ¡¾1% FS
• Ruggedly constructed cases for years of field use
• Lightweight portability
• Zero start (safety interlock feature)
• Output termination: toroid with output lead
• Adjustable overcurrent trip from 10% to 70% of rating
• Internal short circuit protection
 
PX299640
  • 40 kV AC, 10 mA hipot designed primarily for vacuum bottle testing; however, it can be used for testing breakers, switchgear, and many other apparatus
  • One-piece portability for field testing
  • Lightweight (56 lbs., 25 kg)
  • Emergency Off pushbutton
  • Guard ground circuit
 
PX299650
  • 50 kV AC hipot, multi-purpose, rugged design; tests breakers, switchgear, and many other apparatu
  • 40 mA of output current independent of test specimen type (resistive or capacitive)
  • Two-piece construction
  • External interlock provision
  • CE marked 650-2P version available
 
PX299660
  • 60 kV AC hipot designed primarily for vacuum bottle testing and field use; however, it can be used for testing breakers, switchgear, and many other apparatus
  • Tests up to 24.9 kV class interrupters in accordance with ANSI/IEEE C37.60 specifications
  • Portable two-piece unit
  • Digital dwell timer
  • Selectable rate of voltage rise (500 volts/sec, 3000 volts/sec)
  • Failure indicator with reset switch
  • Automatic voltage control
  • Digitally programmable set-point eliminates test voltage overshoot as found with meter relay type voltage control
  • Memory feature included in output voltmeter to record breakdown voltage. Reset switch clears unit after failure occurs
  • Single-ended high voltage transformer develops 0-60 kV AC with respect to ground potential
  • 10 mA of output current independent of test specimen type (resistive or capacitive)
  • External interlock provision
 
SPECIFICATIONS

Model

PX299650 PX299640 PX299660
Input 120 VAC, 60 Hz, single phase, 2 kVA, 20 A
Or 220 VAC, 50 Hz, singe phase, 2 kVA, 11 A
120 or 220 VAC, 50/60 Hz,
single phase, 400 VA, 5 A
120 VAC, 50/60 Hz, single phase, 6 A
Or 220 VAC, 50/60 Hz, single phase, 3 A
Output 0-50 kV AC, 40 mA 0-40 kV AC, 10 mA 0-60 kV AC (single ended), 10 mA
Duty Cycle 5 min ON / 15 min OFF @ 40 mA   

120 Volt
20 min ON / 30 min OFF @ 10 mA
220 Volt
15 min ON / 45 min OFF @ 10 mA

5 min ON / 15 min OFF @ 10 mA
Distortion Less than 5% Less than 5% Less than 5%
Output Termination  Output lead  Output lead Output lead
Metering Single range voltmeter: 0-50 kV AC
Single range ammeter: 0-40 mA
Single range voltmeter: 0-40 kV AC
Single range ammeter: 0-10 mA

Single range voltmeter: 0-60 kV AC
Single range ammeter: 0-10 mA

Timer 1-999 seconds
Dimensions & Weight Controls Controls Controls
16.5" W x 15.25" D x 11.25" H
(419 mm x 388 mm x 286 mm)
31 lbs. (14 kg)
18.5" W x 10.75" D x 19.5" H
(464 mm x 273 mm x 495 mm) 
56 lbs. (25 kg) (120 Volt unit)
16.5" W x 15.25" D x 11.25" H
(419 mm x 388 mm x 286 mm)
31 lbs. (14 kg)
HV Transformer      HV Transformer
15" W x 15" D x 16.5" H
(381 mm x 381 mm x 419 mm)
79 lbs. (36 kg)
14" W x 14" D x 14" H
(356 mm x 356 mm x 356 mm)
70 lbs. (32 kg)
Cables 6 ft. (2 m) input power 8 ft. (2.4 m) input power 8 ft. (2.4 m) input power
10 ft. (3 m) interconnect 10 ft. (3 m) interconnect 10 ft. (3 m) interconnect
10 ft. (3 m) ground 10 ft. (3 m) ground 10 ft. (3 m) ground
5 ft. (1.5 m) output lead 10 ft. (3 m) output lead 5 ft. (1.5 m) output lead
Options Custom cable lengths available Custom cable lengths available Custom cable lengths available

CAT NO. MODEL DEscRIPTION AVAIL PRICE
PX299640   640-0   40kV AC Hipot   Yes   8,748,000
PX299650   650-2P   50 kV AC Hipot   Yes   11,232,000
PX299660   660-10P   60 kV AC Hipot   Yes   12,636,000
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ