ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Àü±â°èÃø±â Electrical > ÀϹÝÃøÁ¤±â

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
MG8447 Premise/Structured Cabling Tester
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:MG8447
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The Megger¢ç SCT100 Premise Wiring Tester checks and verifies UTP and STP patch cables
The Megger¢ç SCT100 Premise Wiring Tester checks and verifies UTP and STP patch cables and installed networks, providing simple and instant results via LED indicators. The product consists of a main and remote unit, both of which indicate shorts, opens, pair reversals and other mis-wires on 2,3, and 4 pair structured wiring systems in accordance with TIA568A/B, ISO11801, EN50173 and USOC standards.
 
Features
  • Shorts, opens, pair reversal, mis-wires
  • STP and UTP (shielded and unshielded)
  • Dual standard (568A and USOC)
  • Continuously sequencing LED
  • Automatic power down
  • Low battery indication
  • Performs the basic test requirements to ensure a structured wiring system is installed correctly
  • Low cost test tool - everybody can have one
  • Master and remote units both indicate faults
  • Also tests patch leads
  • 3 Year Warranty
 
SPECIFICATIONS

The following cable and wiring standards are supported.

UTP TIA568A/B; STP TIA568A/B; UTP USOC; STP USOC
The following faults are indicated on the SCT100 sequencing LED display
Open Circuit Pair The appropriate LED's do not illuminate
Short Circuit Pair The appropriate remote unit LED is not lit
Reversed Pair The appropriate remote LED flashed red
Transposed Pair The appropriate LED's flash out of sequence
Short between Pairs Simultaneous flashing of 2 green LED's
Short between Pairs The same LED flashed green more than once
Correct wiring or wire map leads to the following indication of the SCT100 display
For UTP Cables A sequence of 4 green flashing LED's on main and remote units
For STP Cables A sequence of 5 green flashing LED's on main and remote units
Low Battery A red "low bat" LED is lit when the instrument battery needs replacement

CAT NO. MODEL DEscRIPTION AVAIL PRICE
MG8447   SCT100   Premise/Structured Cabling Tester   Yes   291,600
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ