Test Tools The 199C and 196C with their large, high-resolution, color screen and Digital Persistence mode give you an even better view of complex waveforms in the most demanding troubleshooting applications in the field. In addition to the impressive capabilities. The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions and still a 4 hour battery operation time is assured. The Digital Persistence mode helps to find anomalies and to analyze complex dynamic signals by showing the waveforms amplitude distribution over time using multiple intensity levels and user selectable decay time - it's as if you're looking at the display of an analog, real time oscilloscope. A fast display update rate reveals signal changes instantaneously, useful for instance when making adjustments to a system under test. The high resolution screen together with the deeper memory of 1200 samples per input in Scope mode, or 27,500 samples per input in ScopeRecord mode, reveal more signal detail. In addition to many automatic triggering modes like Connect-and-View for capturing virtually any signal, the meters also have a ¡°Stop-on-Trigger¡± in the ScopeRecord mode. This allows the ScopeMeter 190C Series to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceeding it. Waveform reference allows an acquired trace to be stored and designated reference trace for visual comparisons. Variable gain on channel A helps you compare signals on the two inputs. The Vpwm measurement is for measuring the effective rms output voltage of variable speed motor drives and frequency inverters. Color screens captured while working in the field can easily be copied into reports and documents, using FlukeView¢ç software (color supported from version V4.0 onwards). |
|
Features |
- Color for easy identification of individual waveforms
- Full-size, high resolution screen for revealing more signal detail
- Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
- Fast display update rate for seeing dynamic behavior instantaneously
- Stop-on-Trigger in ScopeRecord¢â mode for storing and analyzing pre-trigger waveform data
- Waveform reference for visual comparisons
- Vpwm function for motor drive and frequency inverter applications
- Up to 200 MHz bandwidth
- Up to 2.5 GS/s real time sampling
- Connect-and-View¢â triggering for an instant stable waveform
- Automatic capture and replay of last 100 screens
- Isolated Inputs (1000 V CAT II / 600 V CAT III)
- 4 hours battery operation
|
| |
| SPECIFICATIONS
|
190C ScopeMeter Series |
Models |
199C |
196C |
Bandwidth (MHz) |
200 |
100 |
Max. Sample Rate |
2.5 GS/s |
1.0 GS/s |
Max Record Length |
1200 Points |
Inputs |
2 Scope and 1 DMM (Isolated) |
Input Sensitivity |
2 mV/div to 100 V/div |
True RMS DMM |
5000 Counts Volts, Amps, Ohms, Continuity, Diode, Temperature |
Display and Display Modes |
Display |
Color |
Envelope Mode |
X |
Waveform Compare |
X |
Pass/Fail Testing |
X |
n/a |
Triggering |
Connect-and-View |
X |
Edge, single, free run |
X |
Video & Video Lines |
X |
Pulse width |
X |
External |
X |
Advanced Functions |
Cursors |
X |
Zoom |
X |
Dual Input Trendplot |
X |
ScopeRecord Mode |
X |
Auto Capture/Replay Last 100 Screens |
X |
Waveform math |
X |
Save Setups & Screens |
10 |
Catalog No. |
Model |
Description |
Price |
120 Series |
|
|
|
FL123 |
123 |
Fluke 123 Industrial 20MHz ScopeMeter |
2,194,020 |
FL123Kit |
123 |
Fluke 123 Industrial 20MHz ScopeMeter with SCC20 |
2,744,820 |
FL124 |
124 |
Fluke 123 Industrial 40MHz ScopeMeter |
2,744,820 |
FL124Kit |
124 |
Fluke 123 Industrial 40MHz ScopeMeter with SCC120 |
3,304,120 |
Color Versions |
|
|
|
FL190199 |
199C |
Fluke 199C 200MHz Hi-Res Color ScopeMeter |
5,498,820 |
FL190197 |
199C/003S |
Fluke 199C 200MHz Hi-Res Color ScopeMeter with SCC Kit |
6,214,860 |
FL190196 |
196C |
Fluke 196C 100MHz Hi-Res Color ScopeMeter |
4,948,020 |
FL190198 |
196C/003S |
Fluke 196C 100MHz Hi-Res Color ScopeMeter with SCC Kit |
5,664,060 |
FL199006 |
199CM |
Fluke 199CM 200MHz Color Medical ScopeMeter |
7,132,860 |
FL199007 |
196CM |
Fluke 196CM 100MHz Color Medical ScopeMeter |
6,582,060 |
Monochrome Versions |
|
|
|
FL192003 |
Flk-192B/003 |
Fluke 192B 60MHz Monochrome ScopeMeter |
3,662,820 |
FL1920031 |
Flk-192B/003S |
Fluke 192B 60MHz Monochrome ScopeMeter with SCC Kit |
4,378,860 |
FL196003 |
Flk-196B/003 |
Fluke 196B 100MHz Monochrome ScopeMeter |
4,213,620 |
FL1960031 |
Flk-196B/003S |
Fluke 196B 100MHz Monochrome ScopeMeter with SCC Kit |
4,912,660 |
FL199003 |
Flk-199B/003 |
Fluke 199B 200MHz Monochrome ScopeMeter |
4,764,420 |
FL1990031 |
Flk-199B/003S |
Fluke 199B 200MHz Monochrome ScopeMeter with SCC Kit |
5,480,460 |
FL199004 |
199BM |
Fluke 199BM 200MHz Monochrome Medical ScopeMeter |
6,398,460 |
FL199005 |
196BM |
Fluke 196BM 100MHz Monochrome Medical ScopeMeter |
5,847,660 |
Accessories |
|
|
|
C120 |
CL120 |
Hard Shell carrying case for 120 Series ScopeMeters |
118,800 |
C125 |
C125 |
Compact soft case with belt loop |
54,000 |
FL1900037 |
C190 |
Hard case for ScopeMeter 190 Series |
291,600 |
FL190038 |
C195 |
Soft Universal Carrying Case for all ScopeMeter models |
267,840 |
BP120 |
BP120 |
spare battery pack |
86,400 |
FL1892 |
FVF-SC1 |
Fluke View Software for Windows |
324,000 |
80-110s |
80-110s |
Clamp-on DC/AC current probe 0-100 Amp |
853,200 |
80-1000s |
I-1000s |
Clamp-on AC current/power probe, 0,1-1000 Amps |
853,200 |
DP120 |
DP120 |
Differential Probe |
907,200 |
ITP120 |
ITP120 |
Optically isolated trigger probes for 123 ScopeMeter |
453,600 |
|
|
|
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|