ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Electronic ÀüÀÚ°èÃø±â > ¿À½Ç·Î½ºÄÚÇÁ Oscilloscope
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
199C Fluke High Resolution Color ScopeMeter
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : Fluke
    ¡¤ ÆǸŰ¡°Ý : ÀüÈ­¹®ÀÇ


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Test Tools
The 199C and 196C with their large, high-resolution, color screen and Digital Persistence mode give you an even better view of complex waveforms in the most demanding troubleshooting applications in the field. In addition to the impressive capabilities. The full-color display makes identification of individual waveforms easier, particularly when displaying large amplitude or multiple overlapping waveforms on screen. On-screen color labels, measurements and warnings are clearly linked to specific waveforms. The bright, high contrast display allows for clear reading under varying light conditions and still a 4 hour battery operation time is assured.
The Digital Persistence mode helps to find anomalies and to analyze complex dynamic signals by showing the waveforms amplitude distribution over time using multiple intensity levels and user selectable decay time - it's as if you're looking at the display of an analog, real time oscilloscope. A fast display update rate reveals signal changes instantaneously, useful for instance when making adjustments to a system under test.
The high resolution screen together with the deeper memory of 1200 samples per input in Scope mode, or 27,500 samples per input in ScopeRecord mode, reveal more signal detail.
In addition to many automatic triggering modes like Connect-and-View for capturing virtually any signal, the meters also have a ¡°Stop-on-Trigger¡± in the ScopeRecord mode. This allows the ScopeMeter 190C Series to store waveform data until the instrument is triggered or until a repetitive trigger signal is interrupted. This way, the instrument will, for example, automatically recognize a power failure and store the waveform data preceeding it.
Waveform reference allows an acquired trace to be stored and designated reference trace for visual comparisons. Variable gain on channel A helps you compare signals on the two inputs. The Vpwm measurement is for measuring the effective rms output voltage of variable speed motor drives and frequency inverters. Color screens captured while working in the field can easily be copied into reports and documents, using FlukeView¢ç software (color supported from version V4.0 onwards).
Features
  • Color for easy identification of individual waveforms
  • Full-size, high resolution screen for revealing more signal detail
  • Digital Persistence for analyzing complex dynamic waveforms like on an analog scope
  • Fast display update rate for seeing dynamic behavior instantaneously
  • Stop-on-Trigger in ScopeRecord¢â mode for storing and analyzing pre-trigger waveform data
  • Waveform reference for visual comparisons
  • Vpwm function for motor drive and frequency inverter applications
  • Up to 200 MHz bandwidth
  • Up to 2.5 GS/s real time sampling
  • Connect-and-View¢â triggering for an instant stable waveform
  • Automatic capture and replay of last 100 screens
  • Isolated Inputs (1000 V CAT II / 600 V CAT III)
  • 4 hours battery operation
SPECIFICATIONS
190C ScopeMeter Series
Models

199C

196C

Bandwidth (MHz)

200

100

Max. Sample Rate

2.5 GS/s

1.0 GS/s

Max Record Length

1200 Points

Inputs

2 Scope and 1 DMM (Isolated)

Input Sensitivity

2 mV/div to 100 V/div

True RMS DMM

5000 Counts Volts, Amps, Ohms, Continuity, Diode, Temperature

Display and Display Modes
Display

Color

Envelope Mode

X

Waveform Compare
X
Pass/Fail Testing

X

n/a

Triggering
Connect-and-View

X

Edge, single, free run
X
Video & Video Lines
X
Pulse width
X
External
X
Advanced Functions
Cursors
X
Zoom
X
Dual Input Trendplot

X

ScopeRecord Mode
X
Auto Capture/Replay
Last 100 Screens

X

Waveform math
X
Save Setups & Screens
10
Catalog No. Model Description Price
120 Series
FL123 123 Fluke 123 Industrial 20MHz ScopeMeter 2,194,020
FL123Kit 123 Fluke 123 Industrial 20MHz ScopeMeter with SCC20 2,744,820
FL124 124 Fluke 123 Industrial 40MHz ScopeMeter 2,744,820
FL124Kit 124 Fluke 123 Industrial 40MHz ScopeMeter with SCC120 3,304,120
Color Versions
FL190199 199C Fluke 199C 200MHz Hi-Res Color ScopeMeter 5,498,820
FL190197 199C/003S Fluke 199C 200MHz Hi-Res Color ScopeMeter with SCC Kit 6,214,860
FL190196 196C Fluke 196C 100MHz Hi-Res Color ScopeMeter 4,948,020
FL190198 196C/003S Fluke 196C 100MHz Hi-Res Color ScopeMeter with SCC Kit 5,664,060
FL199006 199CM Fluke 199CM 200MHz Color Medical ScopeMeter 7,132,860
FL199007 196CM Fluke 196CM 100MHz Color Medical ScopeMeter 6,582,060
Monochrome Versions
FL192003 Flk-192B/003 Fluke 192B 60MHz Monochrome ScopeMeter 3,662,820
FL1920031 Flk-192B/003S Fluke 192B 60MHz Monochrome ScopeMeter with SCC Kit 4,378,860
FL196003 Flk-196B/003 Fluke 196B 100MHz Monochrome ScopeMeter 4,213,620
FL1960031 Flk-196B/003S Fluke 196B 100MHz Monochrome ScopeMeter with SCC Kit 4,912,660
FL199003 Flk-199B/003 Fluke 199B 200MHz Monochrome ScopeMeter 4,764,420
FL1990031 Flk-199B/003S Fluke 199B 200MHz Monochrome ScopeMeter with SCC Kit 5,480,460
FL199004 199BM Fluke 199BM 200MHz Monochrome Medical ScopeMeter 6,398,460
FL199005 196BM Fluke 196BM 100MHz Monochrome Medical ScopeMeter 5,847,660
Accessories
C120 CL120 Hard Shell carrying case for 120 Series ScopeMeters 118,800
C125 C125 Compact soft case with belt loop 54,000
FL1900037 C190 Hard case for ScopeMeter 190 Series 291,600
FL190038 C195 Soft Universal Carrying Case for all ScopeMeter models 267,840
BP120 BP120 spare battery pack 86,400
FL1892 FVF-SC1 Fluke View Software for Windows 324,000
80-110s 80-110s Clamp-on DC/AC current probe 0-100 Amp 853,200
80-1000s I-1000s Clamp-on AC current/power probe, 0,1-1000 Amps 853,200
DP120 DP120 Differential Probe 907,200
ITP120 ITP120 Optically isolated trigger probes for 123 ScopeMeter 453,600
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ