| |
Accepts Current, Voltage, TC, & RTD Inputs, Display: 0.56" (14 mm) High, 4 Digit, Red LED |
Features |
- Accepts Current, Voltage, TC, & RTD Inputs
- Display: 0.56" (14 mm) High, 4 Digit, Red LED
- Factory Calibrated for All Inputs
- Maximum/Minimum Display
- Type 4X, NEMA 4X, IP65 Front
- Universal Power Supply 85-265 VAC or 90-265 VDC
- 12-36 VDC or 12-24 VAC Power Option
- Two Relays & 24 VDC Transmitter Power Options
- Serial Communication Adapters
|
|
RS-232 & RS-422/485 Options |
- Copy Meter Settings to Other Meters
- 3 Year Warranty
|
| | SPECIFICATIONS
Except where noted all specifications apply to operation at +25¡ÆC. |
General |
DISPLAY |
0.56" (14 mm) high, high efficiency red LED. Four digit (-1999 to 9999, automatic lead zero blanking. |
DISPLAY UPDATE RATE |
Process/RTD: 3.7-5/second Thermocouple 1.8-2.5/second |
OVERRANGE |
Display flashes 9999 |
UNDERRANGE |
Display flashes -1999 |
PROGRAMMING METHODS |
Four front panel buttons, PC and MeterView software, or cloning using Copy function |
NOISE FILTER |
Programmable from 2 to 199 (0 will disable filter) |
RECALIBRATION |
All ranges are calibrated at the factory. Recalibration is recommended at least every 12 months. |
MAX/MIN DISPLAY |
The maximum and minimum readings reached by the process are stored until reset by the user or until power to the meter is turned off. |
PASSWORD |
Programmable password restricts modification of programmed settings. |
NON-VOLATILE MEMORY |
All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost. |
POWER |
AC: 85-265 VAC, 50/60 Hz |
VA/W |
DC: 90-265 VDC |
Please inquire |
Optional: 12-36 VDC, 12-24 VAC |
Please inquire |
See table for power consumption |
|
(*X on Model number = 0 or 2) |
Please inquire |
TRANSMITTER |
24 VDC ¡¾ 10% @ 200 mA maximum |
POWER SUPPLY |
(Optional) |
FUSE |
Recommended external fuse: 1 A, 250 V slow blow |
NORMAL MODE REJECTION |
64 dB at 50/60 Hz |
ISOLATION |
4 kV |
ENVIRONMENTAL |
Operating temperature range: 0 to +65¡ÆC |
Storage temperature range: -40 to +85¡ÆC |
Relative humidity: 0 to 90% non-condensing |
CONNECTIONS |
Removable screw terminal blocks accept 12 to 26 AWG wire, RJ11 for serial communication adapters |
ENCLOSURE |
1/8 DIN, high impact plastic, UL 94V-0, color: gray |
FRONT PANEL |
NEMA 4X, IP65. Panel gasket provided |
MOUNTING |
1/8 DIN panel cutout required. Two panel mounting bracket assemblies provided |
TIGHTENING TORQUE |
Mounting bracket screws: 6.2 lb-in (0.7 Nm) Screw terminal connectors: 4.5 lb-in (0.5 Nm) |
OVERALL DIMENSIONS (H x W x D) |
2.45" x 4.68" x 4.19" (62 mm x 119 mm x 106 mm) |
WEIGHT |
8.0 oz (227 g) (no options) 9.7 oz (275 g) (2 relays & 24 V transmitter supply options) |
WARRANTY |
3 years parts and labor |
Process Meter |
INPUTS |
Field selectable: ¡¾20 mADC (0-20, 4-20 mA) and ¡¾10 VDC (0-5, 1-5, 0-10 V) |
ACCURACY |
¡¾0.05% of calibrated span ¡¾1 count |
TEMPERATURE DRIFT |
50 PPM/¡ÆC from 0 to 65¡ÆC ambient |
DECIMAL POINT |
Up to three decimal places for process inputs: d.ddd, dd.dd, ddd.d, or dddd |
CALIBRATION RANGE |
An Error message will appear if input 1 signal and input 2 signals are too close together. |
Input Range |
Minimum Span Input 1 & Input 2 |
4-20 mA |
0.40 mA |
¡¾10 V |
0.20 V |
INPUT IMPEDANCE |
Voltage ranges: greater than 1 MW Current ranges: 50 W |
INPUT OVERLOAD |
Current input protected by resettable fuse Fuse resets automatically after fault is removed | SPECIFICATIONS
Temperature Meter |
INPUTS |
Field selectable: type J, K, T, or E thermocouples; 100 W platinum RTD (0.00385 or 0.00392 curve) |
RESOLUTION |
1¡Æ for all thermocouples and RTD inputs 1¡Æ or 0.1¡Æ for Type T thermocouple |
ACCURACY |
|
Input Type |
Range |
Accuracy |
|
Type J |
–58¡Æ to 1382¡Æ F –50¡Æ to 750¡ÆC |
¡¾2¡ÆF ¡¾1¡ÆC |
|
Type K |
–58¡Æ to 2300¡Æ F–50¡Æ to 1260¡ÆC |
¡¾2¡ÆF ¡¾1¡ÆC |
|
Type T |
–292¡Æ to 700¡Æ F –180¡Æ to 371¡ÆC |
¡¾2¡ÆF ¡¾1¡ÆC |
|
Type E |
–58¡Æ to 1578¡Æ F –50¡Æ to 870¡ÆC |
¡¾2¡ÆF ¡¾1¡ÆC |
|
100 W RTD |
–328¡Æ to 1382¡ÆF –200¡Æ to 750¡ÆC |
¡¾1¡ÆF ¡¾1¡ÆC |
COLD JUNCTION REFERENCE |
Automatic, fixed, no user calibration needed |
TEMPERATURE DRIFT |
¡¾2¡ÆC maximum 0 to 65¡ÆC ambient temperature |
OFFSET ADJUSTMENT |
Programmable to ¡¾19.9¡Æ. This parameter allows the user to apply an offset value to the temperature being displayed. |
INPUT IMPEDANCE |
Greater than 100 kW |
SENSOR BREAK DETECTION |
Open sensor circuit indicated by display flashing OPEn. All relays and alarm status LEDs go to alarm state. |
Serial Communication |
METER ADDRESS |
Programmable between 0 and 99 |
TRANSMIT TIME DELAY |
Programmable between 0 and 199 ms |
TURN AROUND DELAY |
Less than 2 ms (fixed) |
Relays Option |
RATING |
2 SPDT (form C); rated 3 amps @ 30 VDC or 3 amps @ 250 VAC resistive load; 1/14 HP @ 125/250 VAC for inductive loads |
ELECTRICAL NOISE SUPPRESSION |
A suppressor (snubber) should be connected to each relay contact switching inductive loads, to prevent disruption to the microprocessor's operation. Recommended suppressor value: 0.01 ¥ìF/470 W, 250 VAC (PDX6901) |
DEADBAND |
0-100% of full scale, user selectable |
HIGH OR LOW ALARM |
User may program any alarm for high or low trip point. |
RELAY OPERATION |
1. Automatic (non-latching) |
2. Latching |
3. Pump alternation control |
RELAY RESET |
User selectable via front panel buttons |
1. Automatic reset only (non-latching) |
2. Automatic + manual reset at any time (non-latching) |
3. Manual reset only, at any time (latching) |
4. Manual reset only after alarm condition has cleared (latching) |
Automatic reset: Relays will automatically reset when the input passes the reset point. |
Manual reset: Front panel ACK button. Pressing ACK resets all manually resettable relays. |
TIME DELAY |
0 to 199 seconds, on and off delays Programmable and independent for each relay |
FAIL-SAFE OPERATION |
Programmable independent for each relay |
AUTO INITIALIZATION |
When power is applied to the meter, relays will reflect the state of the input to the meter. |
Fail-safe operation: relay coils are energized in non-alarm condition. In case of power failure, relays will go to alarm state. |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
PD885107 |
|
PD765-6R0-0 |
|
Universal Meter with No Options, 85-265 VAC |
|
Yes |
|
429,840 |
PD885108 |
|
PD765-6R0-1 |
|
Universal Meter with 24 VDC Output Option, 85-265 VAC |
|
Yes |
|
516,240 |
PD885109 |
|
PD765-6R2-0 |
|
Universal Meter with 2 Relays Option, 85-265 VAC |
|
Yes |
|
559,440 |
PD88570 |
|
PD765-6R2-1 |
|
Universal Meter with 2 Relays + 24 VDC Output Option, 85-265 VAC |
|
Yes |
|
645,840 |
PD885111 |
|
PD765-7R0-0 |
|
Universal Meter with No Options, 12-36 VDC |
|
Yes |
|
537,840 |
PD885112 |
|
PD765-7R2-0 |
|
Universal Meter with 2 Relays Option, 12-36 VDC |
|
Yes |
|
667,440 |
PD885113 |
|
PDA7420 |
|
OPTIONAL Standard Modular Cable, 7' (2.1 m) FOR Trident Universal Input Meter |
|
Yes |
|
15,120
|
PD885114 |
|
PDA7232 |
|
OPTIONAL RS-232 Serial Adapter FOR Trident Universal Input Meter |
|
Yes |
|
105,840 |
PD885115 |
|
PDA7422 |
|
OPTIONAL RS-422/485 Serial Adapter FOR Trident Universal Input Meter |
|
Yes |
|
105,840
|
PD885116 |
|
PDA7500 |
|
OPTIONAL MeterView Software FOR Trident Universal Input Meter |
|
Yes |
|
105,840 |
PD8993129 |
|
PDX6901 |
|
OPTIONAL Suppressor (snubber): 0.01 µF/470¡Æ, 250 VAC FOR Trident Universal Input Meter |
|
Yes |
|
21,600
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|