ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > Panel Meters > Controllers

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
LA282126 DC in, red LED, 9-37 Vdc power
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:LA282126
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The True RMS Meter displays the true AC RMS value of complex waveforms from 10 Hz to 10 kHz.
The True RMS Meter displays the true AC RMS value of complex waveforms from 10 Hz to 10 kHz. Peaks up to 2.4 times the maximum of each range are accurately processed. Five DC voltage ranges from 200.00 mV to 660.0 V, plus four current ranges from 2.0000 mA to 5.000A, are user selectable and factory precalibrated.

The 5.000A range measures voltage across a built-in 10 mohm current shunt. Readings can easily be scaled for use with external current transfomers and current shunts. High common mode rejection allows stable readings with current shunts located on the high side of the line.
 
Features
  • 99,999 display span
  • 0.1% accuracy
  • Crest factor of 2.4 at full scale
  • Ranges user-selectable & factory precalibrated
  • Scalable for direct readout with external current shunts or current transformers
  • 1/8 DIN, NEMA-4X front panel
  • Screw-clamp connectors
 
SPECIFICATIONS
Display 99,999, 0.56" high LED digits
Accuracy <0.1% FS, 10Hz to 10kHz, 1 to 100% FS
Zero & Span ¡¾99,999 (programmable)
AC Voltage 200mV, 2.0000 V, 20.000 V, 200.00 V, 660 V
AC Current 2.0000 mA, 20.000 mA, 200.00 mA, 5.000 A

CAT NO. MODEL DEscRIPTION AVAIL PRICE
LA282126   L21000DC   DC in, red LED, 9-37 Vdc power   Yes   581,040
LA282127   L20000AC   AC in, red LED, 85-264 Vac power   Yes   529,200
LA282128   L7000AC   AC in, green LED, 9-37 Vdc power   Yes   594,000
LA282129   L21000AC   AC in, red LED, 9-37 Vdc power   Yes   594,000
LA282105   LDR   OPTIONAL Dual 10A Form C relays FOR True RMS Meter for AC Volts & AC Amps   Yes   172,800

 

(same slot as LA282106) 
LA282106   LOC   OPTIONAL Dual isolated solid state relays FOR True RMS Meter for AC Volts & AC Amps   Yes   118,800

 

(same slot as LA282105)¡¡
LA282107   LAO   OPTIONAL Isolated analog output, 0-20 mA & 0-10 V, scalable FOR True RMS Meter for AC Volts & AC Amps   Yes   194,400

 

LA282108   L232   OPTIONAL RS-232 data I/O FOR True RMS Meter for AC Volts & AC Amps   Yes   129,600
(same slot at LA282109)
LA282109   L485   OPTIONAL RS-485 data I/O FOR True RMS Meter for AC Volts & AC Amps   Yes   172,800
(same slot at LA282108)
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ