The Model C48 Timer is available in Single or Dual Preset models.
The Model C48 Timer is available in Single or Dual Preset models. The C48T features a 7 segment, 2 line by 6 digit reflective or backlit LCD display. For the backlit versions, the main display line is red and shows the timer value. The smaller secondary display line is green, and can be used to view the preset values or output time values.

The C48 timer can be configured for a variety of different operating modes to meet most timing application requirements. Twelve timing ranges are available from thousandths of a second to hours and minutes. Decimal Points are used to separate the time units (hours, minutes, seconds). Timing can be cumulative or can reset and start upon each power cycle."On Delay" or "Off Delay", "Single Shot", "Repetitive auto cycling" modes are all supported.

 
Features
  • LCD, 7 segment, 2 line, 6 digit display, positive reflective or negative transmissive models with red top line and green bottom line
  • Solid state and relay output models
  • Field replaceable relay output boards
  • Status indicators for outputs
  • NEMA 4X/IP65 Sealed Front Bezel
  • Programmable user inputs and front panel function key
  • Horizontal or vertical stacking of multiple units
  • 85 to 250 VAC or 18 to 36 VDC/24 VAC powered units
  • RS485 serial communications options
  • UL Recognized Component, File # E137808
 
SPECIFICATIONS

Display

2 Line by 6 digit LCD display; Positive image reflective or negative image transmissive with red (top line) and green (bottom line) backlighting.
Main Display 0.3" (7.62 mm) high digits
Secondary Display 0.2" (5.08 mm) high digits
Power Requirements
AC Versions AC Power: 85 to 250 VAC, 50/60 Hz, 9 VA max
DC Power 11 to 14 VDC @ 150 mA max (Non PNP output models)
  Note: Models with PNP current sourcing outputs must be powered from AC.
DC Versions Continuous
DC Power 18 to 36 VDC; 5.5 W max
AC Power 24 VAC ¡¾ 10%; 50/60 Hz; 7 VA max
  Note: The +10% tolerance range on AC input voltage must be strictly adhered to. DO NOT EXCEED 26.4 VAC.
Sensor Power +12 VDC (¡¾ 15%) @ 100 mA max.
Inputs Run/Stop, Usr. In1, Usr In2, and Usr. In3.
Configurable as current sinking (active low) or current sourcing (active high) inputs via a single plug jumper.
Current Sinking (active low) VIL = 1.5 VDC max, 22 Kohm pull-up to 5 VDC.
Current Sourcing (active high) VIH = 3.5 VDC min., VIN max = 30 VDC; 22 Kohm pull-down.
Run/Stop Response Time 250 usec max.
User Input Response Time 5 msec max.
Time Accuracy ¡¾ 0.01%
Outputs
(Output type and quantity are model dependent)
Solid-State
NPN Open Collector ISNK = 100 mA max. @ VOL = 1.1 VDC max; VOH = 30 VDC max.
PNP Open Collector ISRC = 100 mA max.(See note); VOH = 12 VDC ¡¾15% (using internal supply);
VOH = 13 to 30 VDC (using external supply).
Environmental Conditions Operating Range: 0 to 50¡ÆC

CAT NO. MODEL DEscRIPTION AVAIL PRICE
RLC48TS003   C48T   1/16 DIN 1 Preset Timer, Reflective LCD - OUTPUTS: 1 NPN O.C., 1 Relay - POWER: 85-250VAC   Yes   343,440
RLC48TS013   C48T   1/16 DIN 1 Preset Timer, Backlit LCD - OUTPUTS: 1 NPN O.C., 1 Relay - POWER: 18-36VDC/24VAC   Yes   365,040
RLC48TD007   C48T   1/16 DIN 2 Preset Timer, Reflective LCD - OUTPUTS: 1 Relay, RS485 85 - POWER: 85-250VAC   Yes   434,160
RLC48TD017   C48T   1/16 DIN 2 Preset Timer, Reflective LCD - OUTPUTS: 1 Relay, RS485, POWER: 18-36VDC/24VAC   Yes   455,760
RLC48TD107   C48T   1/16 DIN 2 Preset Timer, Backlit LCD - OUTPUTS: 1 Relay, RS485 85 - POWER: 85-250VAC   Yes   455,760
RLC48TD117   C48T   1/16 DIN 2 Preset Counter, Backlit LCD - OUTPUTS: 1 Relay, RS485 - POWER: 18-36VDC/24VAC   Yes   477,360
RLSFC48   SFC48   OPTIONAL Windows Configuration Software for C48 Meters (3.5" Disk) FOR 1/16 DIN Preset Timers   Yes   Call 031-777-1588
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ