AG Series sensors provide for the monitoring of ground faults in current carrying wires of single
AG Series sensors provide for the monitoring of ground faults in current carrying wires of single or 3-phase grounded circuits. Applications include systems where personnel or equipment require protection against ground fault conditions or systems requiring regulatory approval.

Sample Model Number: AG3-SDT1-120-ENE-TR3 (5/10/30 mA Adjustable Setpoint, Normally Energized, 120 VAC Power Supply, SPDT Relay 1A@120 VAC)

PLEASE SPECIFY 1. ppp = Power Supply (24P = 24 VDC; 24A = 24 VAC; 120 = 120 VAC) 2. sss = Factory Setpoint (AG1 models only). Indicate desired setpoint 005 (5 mA) through 100 (100 mA)

 
SPECIFICATIONS

Setpoint Ranges

Series 1: 5-100 mA factory set, specify when ordering
Series 3: 5, 10 or 30 mA field jumper selectable
Output Isolated Dry Contact Relay
Output Rating 1 A @ 120 VAC, 2 A @ 30 VDC
Off State Leakage None
Isolation Voltage Up to 1,250 VAC
Frequency Range 50-400 Hz
Power Supply 24 VAC/VDC, 120 VAC
Aperture Dia. (in./mm.) 0.75"/19 mm
Environmental -4 to 122 deg. F (-20 to 50 deg. C); 0-95% RH non-condensing
Case UL 94 V-0 Flammability rating

CAT NO. MODEL DEscRIPTION AVAIL PRICE
NK1001   AG1-NCR1-ppp-LA-sss   5-100 mA range, Relay Output, Latching   Usually ships in 7 to 10 days   702,000 
Output: NC 1A @ 120 VAC, 2A @ 30 VDC
NK1002   AG1-NOR1-ppp-LA-sss   5-100 mA range, Relay Output, Latching   Usually ships in 7 to 10 days   702,000
Output: NO 1A @ 120 VAC, 2A @ 30 VDC
NK1003   AG1-SDT1-ppp-DEN-sss   5-100 mA range, Relay Output, Norm. de-energized   Usually ships in 7 to 10 days   453,600
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC
NK1004   AG1-SDT1-ppp-ENE-sss   5-100 mA range, Relay Output, Norm. energized   Usually ships in 7 to 10 days   475,200
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC
NK1005   AG3-NCR1-ppp-LA-TR3   5/10/30 mA adj. setpoint, Relay Output, Latching   Usually ships in 7 to 10 days   648,000
Output: NC 1A @ 120 VAC, 2A @ 30 VDC
NK1006   AG3-NOR1-ppp-LA-TR3   5/10/30 mA adj. setpoint, Relay Output, Latching   Usually ships in 7 to 10 days   648,000
Output: NO 1A @ 120 VAC, 2A @ 30 VDC
NK1007   AG3-SDT1-ppp-DEN-TR3   5/10/30 mA adj. setpoint, Relay Output, Norm. de-energized   Usually ships in 7 to 10 days   432,000
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC
NK1008   AG3-SDT1-ppp-ENE-TR3   5/10/30 mA adj. setpoint, Relay Output, Norm. energized   Usually ships in 7 to 10 days   464,400
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ