AG Series sensors provide for the monitoring of ground faults in current carrying wires of single |
AG Series sensors provide for the monitoring of ground faults in current carrying wires of single or 3-phase grounded circuits. Applications include systems where personnel or equipment require protection against ground fault conditions or systems requiring regulatory approval.
Sample Model Number: AG3-SDT1-120-ENE-TR3 (5/10/30 mA Adjustable Setpoint, Normally Energized, 120 VAC Power Supply, SPDT Relay 1A@120 VAC)
PLEASE SPECIFY 1. ppp = Power Supply (24P = 24 VDC; 24A = 24 VAC; 120 = 120 VAC) 2. sss = Factory Setpoint (AG1 models only). Indicate desired setpoint 005 (5 mA) through 100 (100 mA) |
| SPECIFICATIONS
Setpoint Ranges |
Series 1: 5-100 mA factory set, specify when ordering |
Series 3: 5, 10 or 30 mA field jumper selectable |
Output |
Isolated Dry Contact Relay |
Output Rating |
1 A @ 120 VAC, 2 A @ 30 VDC |
Off State Leakage |
None |
Isolation Voltage |
Up to 1,250 VAC |
Frequency Range |
50-400 Hz |
Power Supply |
24 VAC/VDC, 120 VAC |
Aperture Dia. (in./mm.) |
0.75"/19 mm |
Environmental |
-4 to 122 deg. F (-20 to 50 deg. C); 0-95% RH non-condensing |
Case |
UL 94 V-0 Flammability rating |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
NK1001 |
|
AG1-NCR1-ppp-LA-sss |
|
5-100 mA range, Relay Output, Latching |
|
Usually ships in 7 to 10 days |
|
702,000 |
Output: NC 1A @ 120 VAC, 2A @ 30 VDC |
NK1002 |
|
AG1-NOR1-ppp-LA-sss |
|
5-100 mA range, Relay Output, Latching |
|
Usually ships in 7 to 10 days |
|
702,000 |
Output: NO 1A @ 120 VAC, 2A @ 30 VDC |
NK1003 |
|
AG1-SDT1-ppp-DEN-sss |
|
5-100 mA range, Relay Output, Norm. de-energized |
|
Usually ships in 7 to 10 days |
|
453,600 |
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC |
NK1004 |
|
AG1-SDT1-ppp-ENE-sss |
|
5-100 mA range, Relay Output, Norm. energized |
|
Usually ships in 7 to 10 days |
|
475,200 |
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC |
NK1005 |
|
AG3-NCR1-ppp-LA-TR3 |
|
5/10/30 mA adj. setpoint, Relay Output, Latching |
|
Usually ships in 7 to 10 days |
|
648,000 |
Output: NC 1A @ 120 VAC, 2A @ 30 VDC |
NK1006 |
|
AG3-NOR1-ppp-LA-TR3 |
|
5/10/30 mA adj. setpoint, Relay Output, Latching |
|
Usually ships in 7 to 10 days |
|
648,000 |
Output: NO 1A @ 120 VAC, 2A @ 30 VDC |
NK1007 |
|
AG3-SDT1-ppp-DEN-TR3 |
|
5/10/30 mA adj. setpoint, Relay Output, Norm. de-energized |
|
Usually ships in 7 to 10 days |
|
432,000 |
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC |
NK1008 |
|
AG3-SDT1-ppp-ENE-TR3 |
|
5/10/30 mA adj. setpoint, Relay Output, Norm. energized |
|
Usually ships in 7 to 10 days |
|
464,400 |
Output: SPDT 1A @ 120 VAC, 2A @ 30 VDC | | |
|
|
| |
|