ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > °øÁ¤Á¦¾î process & Control > Transducers/Transmitters

DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ACT287 Thermocouples
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ Á¦Ç°¹øÈ£:ACT287
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The TransPak series two-wire transmitters are compact, rugged units that receive signals
Transmitters are used to amplify and condition the very small electrical signals generated by sensors as they measure the physical variables of a process. Once conditioned to usable levels, these signals are used to drive other instrumentation such as data-loggers, chart recorders, alarms, panel meters and controllers.

The TransPak series two-wire transmitters are compact, rugged units that receive signals and direct sensor inputs, and operate from power derived from the output signal loop. The TransPak series provides a complete line of direct interface and conditioning modules for use with temperature and other process parameters. TransPak transmitters also accept a wide range of other electrical DC and AC voltage and current inputs.

Two-Wire Transmitters
Two-wire transmitters offer several major advantages over conventional four-wire types, which require two wires for the output signal and two more for the power supply, typically 120VAC. In applications where the process sensor may be located up to several thousand feet from the instrument being operated, two-wire transmitters are advantageous because their current output signals do not attenuate or degrade over distance as do voltage signals. Additionally there can be significant savings in wiring cost since only two wires are needed for the power and signal when compared to the four-wire type. They are ideal when no isolation is required between the output signal and power.

Intrinsic Safety
Because two-wire transmitters are powered from the low-level 4-20mA or 10-50mA output current signals, no additional power has to be supplied to the remote transmitting location. This eliminates an associated problem of having to provide and maintain long runs of expensive wiring, and adds the benefit of being able to comply with safety requirements restricting the use of high-voltage (120VAC) in hazardous locations.

Due to their low energy consumption and storage, two-wire transmitters are the only types of transmitters considered for intrinsically safe applications. Many of Action¡¯s TransPaks are Canadian Standards Association (CSA) and CENELEC approved for intrinsically safe operation in hazardous - even explosive - environments when installed in accordance with the manufacturer¡¯s drawings.

 
Input Selection
  • Six types of inputs are available to suit your process needs.
  • DC Voltage or Current
  • Potentiometer
  • Thermocouple
  • AC Voltage or Current
  • RTD
  • Frequency
 
 
CAT NO. MODEL DEscRIPTION AVAIL PRICE
ACT287   T287-0000   Thermocouples: Most standard types and all special types using customer defined tables and polynomials.   Yes   529,200

 

RTD: 2-, 3- and 4-wire, Pt-100, Ni-70 and others. DC mV: -10 to 100mV Potentiometers: 0 to 20kWResistance: 0 to 400W - OUTPUT: 4 – 20mA
ACT680   C680-0001   Isolated Communications Adapter, Configuration and Calibration Software, and User¡¯s Guide.   Yes   464,400

 

ACT9046   AP9046   Action Pak 24/40VDC, 65mA Loop Power Supply   Yes   334,800 
ACT609   T609   24V, 600mA Loop Power Supply   Yes   Call 031-777-1588 
ACT560   V560   3 1/2 digit remote loop powered indicator with wide ranging display   Yes   777,600 
ACT250   T25H-0000   Head Mount Enclosure - 1/2 NPT for Thermowell and Conduit   Yes   64,800 
ACT797   T797-0000   Thermocouples: Most standard types and all special types using customer defined tables and polynomials   Yes   712,800

 

RTD: Pt-100 and others. DC mV: -15 to 115mV - OUPUT - 4 – 20mA 
ACT7971   T797-1000   Thermocouples: Most standard types and all special types using customer defined tables and polynomials.   Yes   810,000

 

RTD: Pt-100 and others. DC mV: -15 to 115mV, IS-FM/CSA certified - OUTPUT 4 – 20mA 
ACT798   T798-0000   Thermocouples: Most standard types and all special types using customer defined tables and polynomials.   Yes   939,600

 

RTD: Pt-100 and others. DC mV: -15 to 115mV, HART communication - OUTPUT - 4 – 20mA 
ACT7981   T798-1000   Thermocouples: Most standard types and all special types using customer defined tables and polynomials.   Yes   1,047,600

 

RTD: Pt-100 and others. DC mV: -15 to 115mV, IS-FM/CSA certified, HART communication - OUTPUT: 4 – 20mA 
ACT7906   T79A-C000   CONFIGURATION SOFTWARE T798   Yes   86,400 
ACT7904   T79A-M000   CONFIGURATION MODEM   Yes   432,000 
ACT7905   T79A-MH00   HART CONFIGURATION MODEM   Yes   1,501,200 
ACT792   T79D-2000   TWO LINE ALPHA-NUMERIC DISPLAY   Yes   378,000
ACT790   T79E-D000   EXPLOSION PROOF HOUSING WITH WINDOW   Yes   334,800
ACT7910   T79E-1000   WEATHER PROOF HEAD-MOUNT ENCLOSURE   Yes   140,400 
ACT79101   T79E-H000   Explosion Proof Head-Mount Enclosure   Yes   205,200 
ACT79102   T79A-E000   Mounting Kit for EP Enclosure   Yes   43,200 
ACT7902   T79A-P000   PIPE MOUNT BRACKET FOR T79E-0/D ONLY   Yes   108,000 
ACT7907   T79A-B000   Bulkhead (flat surface) Mounting Plate   Yes   64,800 
ACT7903   T79A-D000   DIN RAIL MOUNTING KIT   Yes   64,800
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ