The new iD Series signal conditioners combine the accuracy of laboratory instrumentation |
The new iD Series signal conditioners combine the accuracy of laboratory instrumentation with the performance required by demanding industrial applications. The iD Series signal conditioners are ideal for those applications in Data Acquisition, Test & Measurement, Process Control, and Industrial Automation where accuracy, performance, and reliability are critically important. The devices feature three-way isolation of up to 1000 V between the signal inputs, outputs, and power supply. The iD series feature seven (7) models designed for each of the most widely measured signal inputs: Process (DC) Voltage and Current; Strain Gage; Thermocouples; RTDís; AC Voltage; AC Current; Frequency/Pulse. The iD series are available with two different types of signal outputs: Analog or Digital. The iDRN series provides a totally scalable analog output in DC voltage or current. The iDRX series provide a digital RS-485 output. Both iD Series signal conditioners are intelligent microprocessor based instruments that can be scaled and programmed by computer via serial communications, or over an Ethernet network.
iDRN Series Analog Output The iDRN series feature a 0-10 Vdc, or 0-20 mA (including 4-20 mA) analog output signal that is typically scaled to be directly proportional to the input signal.
iDRX Sseries Digital Output The iDRX Series Signal Conditioners provide highly accurate digital outputs. Each module provides an RS-485 Serial output that can be transmitted directly to computers and other devices with serial communications capability, or converted to Ethernet.
EIS-2 - iServer Industrial Microserver • Web Server and an Ethernet/Serial Bridge • Serves up to 32 devices The NEWPORT¢ç EIS-2 "iServer" is a DIN rail device which can connect up to thirty-one (31) iDRX RS-485 instruments to an Ethernet network and the Internet using standard TCP/IP protocol. It can also be used as a simple Serial to Ethernet "bridge" or converter to connect a single iDRN RS-232 device to an Ethernet network and the Internet. |
|
Features |
- ANALOG OR DIGITAL OUTPUTS
- Up to 1000 Vdc Isolation
- iDRN Series Provide 0-10 Vdc, 4-20 mA or 0-20 mA Output
- iDRX Series Provide RS-485 Output, (ASCII Serial Protocol and MODBUS Serial Protocol)
- Free Setup and Configuration Software
|
|
Models Available For: |
- Thermocouple
- RTD
- Process Voltage & Current
- Strain
- Frequency/Pulse
- AC Voltage and Current
|
| |
Input |
Thermocouple |
RTD |
ac Voltage |
ac Current |
Process |
Strain/Bridge |
Frequency Pulse |
Input Type |
Thermocouple temperature sensor |
RTD Temperature sensor Pt100, 500, 1000¥Ø |
ac Voltage |
ac Current |
dc Millivolt, Volt and Current |
Millivolt |
Namur Contact closure low level open collector |
Input Range |
J, K, T, E,R, S, B, N, J DIN thermocouple full range |
a = 385, 392 Full range of RTD 2, 3 or 4-wire |
Full Scale Range: 400 mV to 400 V |
Full Scale Range: 10 mA to 5 A |
Full Scale Range: ¡¾400 mV to ¡¾10 V 0 to 20 mA |
0 to 30 mV 0 to 100 mV ¡¾100 mV |
Full Scale Range |
20k to 200 M pulses |
0 to 50 kHz |
Accuracy |
¡¾1¡ÆC |
¡¾0.5¡ÆC |
0.2% |
0.2% |
0.1% FS |
0.2% FS |
0.01% FS |
0.02% FS |
Resolution |
0.1¡ÆC |
0.1¡ÆC |
10 to 14 Bit |
10 to 14 Bit |
12 to 15 Bit |
13 to 15 Bit |
15 to 19 Bit |
Output |
iDRX Series: 2-wire (half duplex) RS-485/iDRN Series: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA |
Excitation |
N/A |
N/A |
N/A |
N/A |
14 Vdc @ 25 mA |
10 V @ 30 mA |
5, 8.2 and 12.5 Vdc @ 25 mA |
Catalog No. |
NP30016 |
NP30018 |
NP30020 |
NP30022 |
NP30024 |
NP30026 |
NP30028 |
|
iDRN RS-232 ANALOG |
Catalog No. |
NP30017 |
NP30019 |
NP30021 |
NP30023 |
NP30025 |
NP30027 |
NP30027 |
|
iDRX RS-485 |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
NP30013 |
|
EIS-2 |
|
iServer Industrial MicroServer¢â with screw termianl serial port |
|
Yes |
|
421,200 |
NP30014 |
|
EIS-2-RJ |
|
iServer Industrial MicroServer¢â with RJ45 serial port |
|
Yes |
|
421,200 |
NP30015 |
|
IBRN-PS-1000 |
|
Power Supply (switching) 95 to 240 Vac input, 24 Vdc output @ 850mA (power up to 7 units) |
|
Yes |
|
324,000
|
NP30016 |
|
iDRN/iDRX-TC |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with Thermocouple Temperature Sensor |
|
Yes |
|
702,000
|
NP30018 |
|
iDRN/iDRX-RTD |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with RTD Temperature Sensor |
|
Yes |
|
766,800
|
NP30020 |
|
iDRN/iDRX-ACV |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with ac Voltage |
|
Yes |
|
745,200
|
NP30022 |
|
iDRN/iDRX-ACC |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with ac Current |
|
Yes |
|
745,200
|
NP30024 |
|
iDRN/iDRX-PR |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with dc Millivolt, Volt and Current |
|
Yes |
|
702,000
|
NP30026 |
|
iDRN/iDRX-ST |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with Millivolt |
|
Yes |
|
745,200
|
NP30028 |
|
iDRN/iDRX-FP |
|
iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with Namur Contact Closure Low Level Open Collector |
|
Yes |
|
637,200
|
NP30017 |
|
iDRN/iDRX-TC |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with Thermocouple Temperature Sensor |
|
Yes |
|
540,000
|
NP30019 |
|
iDRN/iDRX-RTD |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with RTD Temperature Sensor |
|
Yes |
|
540,000
|
NP30021 |
|
iDRN/iDRX-ACV |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with ac Voltage |
|
Yes |
|
583,200
|
NP30023 |
|
iDRN/iDRX-ACC |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with ac Current |
|
Yes |
|
583,200
|
NP30025 |
|
iDRN/iDRX-PR |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with dc Millivolt, Volt and Current |
|
Yes |
|
594,000
|
NP30027 |
|
iDRN/iDRX-ST |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with Millivolt |
|
Yes |
|
648,000
|
NP30029 |
|
iDRN/iDRX-FP |
|
iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with Namur Contact Closure Low Level Open Collector |
|
Yes |
|
540,000
|
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|