The new iD Series signal conditioners combine the accuracy of laboratory instrumentation
The new iD Series signal conditioners combine the accuracy of laboratory instrumentation with the performance required by demanding industrial applications. The iD Series signal conditioners are ideal for those applications in Data Acquisition, Test & Measurement, Process Control, and Industrial Automation where accuracy, performance, and reliability are critically important.
The devices feature three-way isolation of up to 1000 V between the signal inputs, outputs, and power supply.
The iD series feature seven (7) models designed for each of the most widely measured signal inputs: Process (DC) Voltage and Current; Strain Gage; Thermocouples; RTDís; AC Voltage; AC Current; Frequency/Pulse.
The iD series are available with two different types of signal outputs: Analog or Digital. The iDRN series provides a totally scalable analog output in DC voltage or current. The iDRX series provide a digital RS-485 output. Both iD Series signal conditioners are intelligent microprocessor based instruments that can be scaled and programmed by computer via serial communications, or over an Ethernet network.

iDRN Series Analog Output
The iDRN series feature a 0-10 Vdc, or 0-20 mA (including 4-20 mA) analog output signal that is typically scaled to be directly proportional to the input signal.

iDRX Sseries Digital Output
The iDRX Series Signal Conditioners provide highly accurate digital outputs. Each module provides an RS-485 Serial output that can be transmitted directly to computers and other devices with serial communications capability, or converted to Ethernet.

EIS-2 - iServer Industrial Microserver
• Web Server and an Ethernet/Serial Bridge
• Serves up to 32 devices
The NEWPORT¢ç EIS-2 "iServer" is a DIN rail device which can connect up to thirty-one (31) iDRX RS-485 instruments to an Ethernet network and the Internet using standard TCP/IP protocol. It can also be used as a simple Serial to Ethernet "bridge" or converter to connect a single iDRN RS-232 device to an Ethernet network and the Internet.

 
Features
  • ANALOG OR DIGITAL OUTPUTS
  • Up to 1000 Vdc Isolation
  • iDRN Series Provide 0-10 Vdc, 4-20 mA or 0-20 mA Output
  • iDRX Series Provide RS-485 Output, (ASCII Serial Protocol and MODBUS Serial Protocol)
  • Free Setup and Configuration Software
 
Models Available For:
  • Thermocouple
  • RTD
  • Process Voltage & Current
  • Strain
  • Frequency/Pulse
  • AC Voltage and Current
 
Input Thermocouple

RTD

ac Voltage

ac Current

Process

Strain/Bridge

Frequency Pulse

Input Type Thermocouple
temperature
sensor 

RTD Temperature
sensor
Pt100, 500, 1000¥Ø 

ac Voltage

ac Current

dc Millivolt,
Volt
and Current

Millivolt

Namur
Contact closure
low level
open collector

Input Range J, K, T, E,R, S, B, N, J DIN thermocouple full range

a = 385, 392
Full range of RTD
2, 3 or 4-wire

Full Scale Range:
400 mV to 400 V

Full Scale Range:
10 mA to 5 A

Full Scale Range:
¡¾400 mV to ¡¾10 V
0 to 20 mA

0 to 30 mV
0 to 100 mV
¡¾100 mV

Full Scale Range

20k to
200 M pulses

0 to
50 kHz

Accuracy ¡¾1¡ÆC

¡¾0.5¡ÆC

0.2%

0.2%

0.1% FS

0.2% FS

0.01% FS

0.02% FS
Resolution 0.1¡ÆC

0.1¡ÆC

10 to 14 Bit

10 to 14 Bit

12 to 15 Bit

13 to 15 Bit

15 to 19 Bit

Output iDRX Series: 2-wire (half duplex) RS-485/iDRN Series: 0 to 10 V @ 10 mA max; 0 to 20 mA or 4 to 20 mA
Excitation N/A

N/A

N/A

N/A

14 Vdc @ 25 mA

10 V @ 30 mA

5, 8.2 and 12.5 Vdc @ 25 mA

Catalog No. NP30016

NP30018

NP30020

NP30022

NP30024

NP30026

NP30028

 
iDRN RS-232 ANALOG
Catalog No. NP30017

NP30019

NP30021

NP30023

NP30025

NP30027

NP30027

 
iDRX RS-485

CAT NO. MODEL DEscRIPTION AVAIL PRICE
NP30013   EIS-2   iServer Industrial MicroServer¢â with screw termianl serial port   Yes   421,200 
NP30014   EIS-2-RJ   iServer Industrial MicroServer¢â with RJ45 serial port   Yes   421,200 
NP30015   IBRN-PS-1000   Power Supply (switching) 95 to 240 Vac input, 24 Vdc output @ 850mA (power up to 7 units)   Yes   324,000

 

NP30016   iDRN/iDRX-TC   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with Thermocouple Temperature Sensor   Yes   702,000

 

NP30018   iDRN/iDRX-RTD   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with RTD Temperature Sensor   Yes   766,800

 

NP30020   iDRN/iDRX-ACV   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with ac Voltage   Yes   745,200

 

NP30022   iDRN/iDRX-ACC   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with ac Current   Yes   745,200

 

NP30024   iDRN/iDRX-PR   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with dc Millivolt, Volt and Current   Yes   702,000

 

NP30026   iDRN/iDRX-ST   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with Millivolt   Yes   745,200

 

NP30028   iDRN/iDRX-FP   iDRN RS-232 Analog Output Signal Conditioner/ Transmitter with Namur Contact Closure Low Level Open Collector   Yes   637,200

 

NP30017   iDRN/iDRX-TC   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with Thermocouple Temperature Sensor   Yes   540,000

 

NP30019   iDRN/iDRX-RTD   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with RTD Temperature Sensor   Yes   540,000

 

NP30021   iDRN/iDRX-ACV   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with ac Voltage   Yes   583,200

 

NP30023   iDRN/iDRX-ACC   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with ac Current   Yes   583,200

 

NP30025   iDRN/iDRX-PR   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with dc Millivolt, Volt and Current   Yes   594,000

 

NP30027   iDRN/iDRX-ST   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with Millivolt   Yes   648,000

 

NP30029   iDRN/iDRX-FP   iDRX RS-485 Digital Output Signal Conditioner/ Transmitter with Namur Contact Closure Low Level Open Collector   Yes   540,000

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ