»ê¼Ò³óµµ°¡ 18% ÀÌÇϽà °æº¸ºÎÀú°¡ ¿ï¸®°í ¹åµ¥¸®°¡ ºÎÁ· ÇÒ ¶§ ¹åµ¥¸® ·¥ÇÁ°¡ ²¨Áö¸é¼­ °ÇÀüÁö ±³È¯ À» ¾Ë¸².

¡Ü»ê¼Ò³óµµ°¡ 18% ÀÌÇϽà °æº¸ºÎÀú°¡ ¿ï¸®°í ¹åµ¥¸®°¡ ºÎÁ· ÇÒ ¶§ ¹åµ¥¸® ·¥ÇÁ°¡ ²¨Áö¸é¼­ °ÇÀüÁö ±³È¯ À» ¾Ë¸².
¡Ü¸ÞŸ¿¡ Á¶¸íÀÌ ÀÖ¾î ¾îµÎ¿î °÷¿¡¼­µµ ÃøÁ¤°¡´É.
¡Ü¹æÆø±¸Á¶(i2G3)
¡Üµ¶ÀÚ °³¹ßÇÑ ¸¶ÀÌÅ©·Î ¿¡¾îÆßÇÁ¸¦ »ç¿ëÇÏ¿© Á¶ÀÛÀÌ °£Æí.
¡ÜÀüÁö´Â 1ÀÏ 3ºÐ°£ 10ȸ »ç¿ëÇÔÀ» ±âÁØÀ¸·Î 2°³¿ù ¿¬¼Ó »ç¿ë.
¡Ü¿¬¼Ò¿ë »ê¼Ò ³óµµÃøÁ¤±â(XP0-318E)µµ ÀÖ½À´Ï´Ù.

¡¡

MODEL

XPO- 318 (°æº¸±â´ÉºÎÂø )

°ËÁö´ë»óGAS

»ê¼Ò

°Ë Áö ¿ø ¸®

°Ý¸· Galvani ÀüÁö½Ä

ä Ãë ¹æ ½Ä

ÀÚµ¿ ÈíÀÔ½Ä

Áö ½Ã Ç¥ ½Ã

¾×Á¤ LCD 3ÀÚ¸® µðÁöÅÐ ¼ýÀÚ

°Ë Áö ¹ü À§

0¡­25VOL%

Áö ½Ã Á¤ µµ

°¢ Áö½Ã³óµµÀÇ ¡¾0.3% (JIS-T8201±Ô°ÝÀº ¡¾0.7%)

°æº¸ ¼³Á¤Ä¡

18VOL% ÀÌÇÏ

°æ º¸ ¹æ ½Ä

»ê¼Ò³óµµ 18% ÀÌÇϽà À§Çè °æº¸ BUZZER¿ï¸²,ÀüÁöÁ¾·á ¿¹°í (BATT Lamp°¡ ¼Òµî)

»ç¿ë¿Âµµ¹üÀ§

0¡­40¡É

Àü ¿ø

´Ü 3Çü °ÇÀüÁö 4°³

¿¬¼Ó»ç¿ë½Ã°£

AlkaliÀüÁö»ç¿ëÀÇ °æ¿ì ¾à 24½Ã°£(´Ü, MeterÁ¶¸í¡¤°æº¸°¡ ¾øÀ» ¶§)

¹æ Æø ±¸ Á¶

º»Áú ¾ÈÀü¹æÆø±¸Á¶ i2G3

Å©±â, ¹«°Ô

W84¡¿H190¡¿D40(mm), ¾à 800g

ºÎ ¼Ó ȸ ·Î

MeterÁ¶¸í

ºÎ ¼Ó Ç°

Leather case, °ÇÀüÁö, GAS µµÀÔ°ü,Drain Filter, Filter Element, ÈíÀÔÆÄÀÌÇÁ¿ë °í¹«

Ưº° ºÎ¼ÓÇ°
(º° ¸Å)

Sampling Float, ³Ã°¢¿ë Drain Filter set,¿ÜºÎ Ãâ·Â Connector, GasÈíÀÔ°ü.

Description
The Model COsmotector XPO-318 is a compact, lightweight automatic sampling instrument which may be used to measure the oxygen content of the atmosphere od any confined space over a range of 0-25%. Typical applications include checking manholes, sewers,tanks and other areas of potential oxygen in hydrocabons, and tail gas monitoring in oXidation reactions.
The sample of the atmosphere to be tested ts drawn through a sampling tube automatically and continuously by means of an internal, extremely low power drain micropump, passed over the transducer of a galvanic cell and exhaused to atmosphere. the oxygen content is indicated directry on a large, clear liquid crystal diode(LCD) digitalmeter.
A single multiposition switch turns the instrument on, checks battery voltage and selects operation with or without alarm. With the selector Switch set to "Alarm"position,an intermittent tone sounds an alarm when the oxygen concentration dorps below 18%

Product specification
Detection Principle Galvanic cell
Monitorring Range 0-25% O2
Accuracy +-0.7% of o2
Response Max. 20seconds to 90%(With 1m long sampling tube connected)
Alarm Presetting Level Factry present at 18% O2
(available, at other present point in request
Temperature Range 0 degree C to 45 degree C
Intrinsic Safety d2G3
Sensor life Min. 6months


¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ