ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > ½ë¼­ > ·Î°Å¿ë ½ë¼­ > ½Ç³»°øÁ¶ ½ë¼­

 
ZA9903AB/ZA9904AB True/Effective Measuring Modules
    ¡¤ °í°´¼±È£µµ :
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
True/Effective Measuring Modules for AC Voltages and AC Current Type
ZA9903AB/ZA9904AB
True/Effective Measuring Modules for AC Voltages and AC Current Type


¡Ü Independent, full digital acquisition of the true/effective values of an AC variable.
¡Ü Measuring signals with any course of a curve are digitised with 1kHz.
¡Ü Pure digital data transmission to the measuring instrument.
¡Ü Acquisition of the frequency through a second measuring channel.
¡Ü Connector sockets electrically isolated and overvoltageprotected.

¢Ñ The measuring module is not designed for operation with selector switch board ES5590MF.
Technical Data:
TRMS
Accuracy: 0.1% of fin. val. ¡¾ 2 digits
Sampling rate: 1kHz
Resolution: 12 bit, ¡¾ 2048 digits for Uss
Frequency range: 20.0 ¡¦ 250Hz
Meas. period/transient time: 0.5s
Frequency
Accuracy: ¡¾ 0.1Hz
Sampling rate: 1kHZ
Resolution: 0.1Hz
Sensitivity: 10% of final value
Frequency range: 20.0 ¡¦ 250Hz
Meas. period/transient time: 0.5s
  
Electrical isolation: 1kV permanent, 5kV for 1s
Housing: polystyrene,
dim. L 100 x W 54 x H 31mm
Sockets: touchproof, ¨ª 4mm
Operating voltage: 6 ¡¦ 14V
through ALMEMO¢ç device
Current consumption: < 40mA
(connector and module)

Types (incl. touchproof connecting cable):

AC Voltage 
Order No. Meas. range Resolution Peak Overload Internal resistance
ZA9903AB1 130.0mVrms ©ö) 0.1mV 0.2V 400V 0.5M§Ù
ZA9903AB2 1.300Vrms 1mV 2V 400V 0.8M§Ù
ZA9903AB3 13.00Vrms 10mV 20V 500V 1M§Ù
ZA9903AB4 130.0Vrms 0.1V 200V 500V 1M§Ù
ZA9903AB5 400Vrms 1V 1000V 1000V 4M§Ù
©ö) When using the measuring module for the purposes of current measurement with an external shunt, the shunt must be looped into the neutral conductor (not into the phase).

AC Current
Order No. Meas. range Resolution Peak Overload Internal resistance
ZA9904AB1 1.000Arms 1mA 2A 10A©÷) 0.10§Ù
ZA9904AB2 10.00Arms 10mA 20A 20A©÷) 0.01§Ù
©÷)Without fuse, overload condition only up to 1 minute maximum
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ