|
|
| |
Á¦Ç°°³¿ä
¨ª testo 171Àº ¿Âµµ (NTC) ¹×/¶Ç´Â »ó´ë ½Àµµ¿¡ ´ëÇÑ ¼¾¼¸¦ ³»ÀåÇÏ´Â °í¼º´ÉÀÇ ·Î°Å ½Ã¸®Áî
¨ª Å« ¸Þ¸ð¸®¸¦ °¡Áö°í Á¤È®ÇÏ¸ç ¶ÇÇÑ ¾Ë·ç¹Ì´½ ÇǸ· ó¸®µÈ ÄÉÀ̽º »ç¿ë
|
|
±â¼úµ¥ÀÌÅÍ
Testo 171 Series |
Testo 171-2 |
Testo 171-3 |
Testo 171-6 |
Á¦Ç° ±×¸² |
|
|
|
¿Âµµ ÃøÁ¤ ¹üÀ§ |
-20 ~ 70 ¡É (-4 ~ 158>¡ÆF ) |
-25 ~ 50 ¡É (-14 ~ 122 ¡ÆF) |
-50 ~ 120 ¡É (-58 ~ 248 ¡ÆF) |
¼¾¼ |
NTC |
NTC |
NTC |
½Àµµ ¹üÀ§ |
0 ~ 100% |
0 ~ 100% |
0 ~ 100% |
ÃøÁ¤ ¼Óµµ |
2ÃÊ ~ 24 ½Ã°£ (ÀÚÀ¯·ÎÀÌ ¼±ÅÃ) |
2ÃÊ ~ 24 ½Ã°£ (ÀÚÀ¯·ÎÀÌ ¼±ÅÃ) |
2ÃÊ ~ 24 ½Ã°£ (ÀÚÀ¯·ÎÀÌ ¼±ÅÃ) |
¸Þ¸ð¸® ¿ë·® |
55,000°³ÀÇ ÃøÁ¤°ª |
55,000°³ÀÇ ÃøÁ¤°ª |
55,000°³ÀÇ ÃøÁ¤°ª |
º¸È£ Ŭ·¡½º |
IP65 |
IP65 |
IP65 |
ÄÉÀÌ½Ì |
¾Ë·ç¹Ì´½ ÇǸ·Ã³¸® |
¾Ë·ç¹Ì´½ ÇǸ·Ã³¸® |
¾Ë·ç¹Ì´½ ÇǸ·Ã³¸® |
Ä¡¼ö |
5.16 x 2.68 x 1.02" |
5.16 x 2.68 x 1.02" |
5.16 x 2.68 x 1.02" |
¼ÒÇÁÆ®¿þ¾î |
Windows 3.0 ÀÌ»ó ÇÊ¿ä |
Windows 3.0 ÀÌ»ó ÇÊ¿ä |
Windows 3.0 ÀÌ»ó ÇÊ¿ä |
º¸Áõ |
2³â |
2³â |
2³â |
| Àç°í: 1´ë |
Electronic thermohygrograph
testostor 171-2 |
testostor 171-2, humidity logger for %RH, ¡ÆC, td, incl. starting magnet, battery and calibration protocol
Part no. 0577 1712 2,693,000 ¿ø |
testostor 1722 |
With alarm output testostor 1722, humidity data logger for %RH, ¡ÆC, td, incl. alarm output, starting magnet, battery and calibration protocol
Part no. 0577 1722 3,408,000 ¿ø | |
testostor 171-2 is a compact, accurate data logger with an internal probe, parallel dew point measurement and large memory capacity.
testostor 1722, similar to testostor 171-2 but with alarm output. The signal device which can be connected sends out a signal when the specified limits are exceeded.
¡Ø¡Ü On-site application: Testo software for Palm OS¢ç replaces laptop/PC ¡Ü Control and adjustment possible using adjustment set ¡Ü Sintered cap protection for dusty areas ¡Ü DKD calibration
|
Monitors constant ambient conditions in clean rooms during the manufacture of pharmaceutical products, electronic components... (testostor 1722 + signal device) |
Analysis via infrared printer: the infrared printer offers you the option of printing the data saved in the testostor logger directly on location. | |
Ordering data for Accessories |
Part no. |
Display can be attached to data logger For quick checks on location |
0554 0176 581,000¿ø |
Display with print option, can be attached to data logger For quick checks on location |
0554 0175 755,000 ¿ø |
Testo printer with 1 roll of thermal paper and 4 AA size batteries Prints readings on location |
0554 0545 456,000 ¿ø |
Recharger for printer (with 4 standard rech. batt.) |
0554 0110 132,000 ¿ø |
Spare thermal paper for printer (6 rolls) |
0554 0569 38,000 ¿ø |
Spare thermal paper for printer (6 rolls) Measurement data documentation legible for up to 10 years |
0554 0568 43,000 ¿ø |
Optical alarm display for data logger, battery-operated Warns if limits have been exceeded |
0628 0025 571,000 ¿ø |
Signal device for testostor 1722 ( with connection cable) for reliable signals when the programmed limit values are exceeded |
0554 1722 813,000 ¿ø |
Holder with lock for data logger Theft-proof |
0554 1782 92,000 ¿ø |
¡Øtestostor 171 data logger, connection for Palm OS¢ç In connection with ComSoft 3, Part no.: 0554 0830 |
0554 0805 485,000 ¿ø |
ComSoft 3 - Professional with data management Incl. database, analysis and graphics function, data analysis, trend curve |
0554 0830 617,000 ¿ø |
¡ØComSoft 3 - For requirements in accordance with CFR 21 Part 11 Incl. database, analysis and graphics function, data analysis, trend curve |
0554 0821 2,805,000 ¿ø |
Interface, attachable to data logger |
0554 1781 112,000 ¿ø |
Spare battery for testostor 171 |
0515 0018 87,000 ¿ø |
Control and humidity adjustment set 11.3%RH/75.3%RH incl. adapter for humidity probes |
0554 0660 487,000 ¿ø |
Stainless steel sintered cap, ¨ª 21 mm, can be screwed onto humidity probe Protection in case of high mechanical load and high velocities |
0554 0640 77,000 ¿ø |
Transport case (plastic) for data loggers (max. 5 off) and accessories |
0516 0117 316,000 ¿ø |
DKD calibration certificate/Humidity Humidity data logger; cal. points 11.3%RH and 75.3%RH at +25¡ÆC; per channel/instrument |
0520 0246 689,000 ¿ø |
ISO calibration certificate/Humidity Humidity data logger; calibration points 11.3%RH and 75.3%RH at +25¡ÆC; per channel/instrument |
0520 0076 268,000 ¿ø |
ISO calibration certificate/Temperature Temperature data logger; calibration points -8¡ÆC; 0¡ÆC; +40¡ÆC per channel/instrument |
0520 0171 230,000 ¿ø | |
Recommended kit: |
testostor 1722, standard set with alarm function |
testostor 1722 humidity logger
Signal device for testostor 1722
ComSoft 3
Interface
Holder with lock
Transport case (plastic) |
Technical data |
Probe type |
Testo humid. sensor, cap. |
NTC |
Calc. parameter |
Meas. range |
0... +100 %RH |
-20... +70 ¡Æ |
-20... +70 ¡ÆC td |
Accuracy ¡¾ 1 digit |
¡¾2 %RH (+2... +98 %RH) |
¡¾0.4 ¡ÆC (-10... +50 ¡ÆC) ¡¾0.5 ¡ÆC (-20... -10.1 ¡ÆC) ¡¾0.5 ¡ÆC (+50.1... +70 ¡ÆC) |
|
Resolution |
0.1 %RH (0... +100 %RH) |
0.1 ¡ÆC (-20... +70 ¡ÆC) |
|
Memory |
55000 |
Measuring rate: 2s to 24h selectable |
Material /Housing |
Aluminium, anodized |
Battery life: up to 5 years |
Protection class |
IP65 |
Software: Menu-driven from Microsoft Windows |
Oper. temp. |
-20... +70 ¡ÆC |
95 / NT 4 Service pack 4 |
Storage temp. |
-40... +85 ¡ÆC |
|
Battery type |
Lithium battery (2032) |
|
Dimensions |
131x68x84 mm |
|
Weight |
320 g |
|
Warranty |
2 years |
| | | | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
|
|