¹üÀ§: 0 ~ 2000ppm, LCD Ç¥½Ã±â´É, relay Ãâ·Â ±â´É
310_4x6_small.jpg (31868 bytes)

AirSense Model 310

Carbon Dioxide Sensor

 

This state-of-the-art instrument measures carbon dioxide (CO2 ) concentrations in the parts per million (ppm) range and is ideal for applications ranging from conference rooms to home gyms.

Fresh air contains 350-400 ppm CO2. Human respiration and combustion by-products from furnaces, fireplaces, and household appliances can easily raise indoor levels above 2000 ppm. With your AirSense¢â Model 310e, you can watch CO2 levels rise as people enter a room.

According to the National Institutes of Occupational Safety and Health, increased levels of CO2 may contribute to "Sick Building Syndrome" and symptoms such as hyperventilation, headache, dizziness, shortness of breath, and drowsiness. The AirSense¢â Model 310e CO2 monitor provides a continuous, accurate reading of indoor CO2 levels, making it easy to maintain an optimum level of fresh air.

The AirSense¢â Model 310 is easy to install and support. Measurement output is via a 4 - 20 mA current loop or a 0 to 10 volt interface. A completely isolated power supply eliminates any ground loop or electrical interaction problems when multiple units are connected to the same controller. Low power consumption makes the AirSense¢â Model 310e perfect for battery-operated or other power-sensitive applications.

The AirSense¢â Model 310e¡¯s single gas verification makes field calibration a snap, and its superior design means significantly longer calibration intervals. Unlike other models, its simple user interface has no complicated menus: all maintenance and calibration operations are easily performed even on units with no display.

The AirSense¢â Model 310e¡¯s versatility is enhanced by options to satisfy most applications. The clear, bright 0.4" high LCD display option is readable from any angle for installations where local annunciation of the CO2 concentration is desired. For direct control applications, the relay option can be configured to open or close above the set point and is easily adjusted in the field. For plenum sampling requirements, the popular duct option is easy to install.

The high-performance AirSense¢â Model 310e uses an advance Non-Dispersive Infrared (NDIR) sensoring systems to assure quick and reliable CO2 response.

Manuals pdf.gif (218 bytes) AirSense Model 310 Manual

 Model 310

Configurations

M310-nodisplay.jpg (42295 bytes)  310_4x6-small-2.jpg (11380 bytes)
LCD display no yes
Application location
 wall  wall
Sample method no no
Diffusion method yes yes
Transformer option option
Duct kit no no
Relay option option

 

Specifications

 

Operating Principle

Non-dispersive infrared (NDIR)

Gas sampling method

Diffusion or available duct kit

Measurement Range

0 - 2000 ppm CO2

Meaurement accuracy

?/span> 5% of reading or ?/span> 75 ppm, whichever is greater

Repeatability

?/span> 20 ppm

Recommended calibration interval

5 Years

Warm up time

Less than 1 minute

Operating temperature range

0 to 50 ?/span> Celsius

Operating humidity range

5 - 90% RH, (non condensing)

Storage temperature

-30 to + 60 ?/span> C

Power requirements

18 - 28 VRMS AC, 18 - 30 VDC

Power consumption

Less than 1 watt

Calibration adjustments

Span only (offset electronically nulled)

Calibration verification procedure time

10 minutes typical

Case dimensions

5.2" x 3.2" x 1.4"

Voltage output (linear)

0 - 10 VDC full scale standard.

Range field adjustable from 1-10 VDC

Current output (linear)

4 - 20 mA (RLOOP: 400 W maximum)

Warm up time

Less than 1 minute

Weight

12 Oz. (.35 Kg)

Optional Digital Display

4 digit, .35" LCD

Optional

setpoint range

0 to 2000 ppm

High Limit

contact polarity

jumper selectable

Contact

contact rating

2A @ 24 VAC

Operating life expectancy

10 years typical

Warranty

One year, parts and labor through repair or exchange

 

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ