Features |
- Models EH450 and EH470 include built-in non-contact IR thermometer with laser!
- Low current capability – measure down to 0.1µA
- Audible and visual input alerts
- Easy to read 1 inch digits on backlit display
- MAX (Model EH450) and RELATIVE (Models EH430 and EH470) functions
- IR thermometer has 8:1 distance to target ratio, 0.95 fixed emissivity
- Complete with CAT III test leads, multi-position tilt stand and velcro strip for hanging, protective holster with test lead holder, bead wire temperature probe (except Model EH450) and 9V battery
|
Advantages of Non-Contact InfraRed Temperature with laser |
- Troubleshoot - Quickly locate hot spots
- Distance - 8:1 distance to target ratio allows for measurements in areas that are normally difficult or unsafe to reach
- Speed - Point and shoot with final result in seconds
- Convenience - No cables or probes to connect, break or lose
|
|
| |
|
| SPECIFICATIONS
Models |
EH410 |
EH411 |
EH430 |
EH450 |
EH470 |
Description |
Manual Ranging
DMM |
True RMS
DMM |
True RMS
Autoranging DMM |
DMM +
IR Thermometer |
True RMS DMM +
IR Thermometer |
Backlit Display |
2000 Counts |
4000 Counts |
2000 Counts |
4000 Counts |
4000 Counts |
Basic Accuracy |
¡¾0.5% (VDC) |
¡¾0.3% (VDC) |
¡¾0.5% (VDC) |
¡¾0.3% (VDC) |
¡¾0.3% (VDC) |
DC Voltage |
0.1mV to 600V |
0.1mV to 600V |
0.1mV to 600V |
0.1mV to 600V |
0.1mV to 600V |
AC Voltage |
1mV to 600V |
1mV to 600V |
0.1mV to 600V |
0.1mV to 600V |
0.1mV to 600V |
DC Current |
0.1¥ìA to 20A |
0.1¥ìA to 20A |
0.1¥ìA to 20A |
0.1¥ìA to 20A |
0.1¥ìA to 20A |
AC Current |
0.1mA to 20A |
0.1mA to 20A |
0.1¥ìA to 20A |
0.1¥ìA to 20A |
0.1¥ìA to 20A |
Resistance |
0.1¥Ø to 20M¥Ø |
0.1¥Ø to 20M¥Ø |
0.1¥Ø to 40M¥Ø |
0.1¥Ø to 20M¥Ø |
0.1¥Ø to 40M¥Ø |
Capacitance |
— |
— |
0.01nF to 100¥ìF |
— |
0.01nF to 100¥ìF |
Frequency |
— |
— |
0.001Hz to 10MHz |
— |
0.001Hz to 10MHz |
Temperature |
-4 to 1382¡ÆF |
-4 to 1382¡ÆF |
-4 to 1382¡ÆF |
— |
-4 to 1382¡ÆF |
(Type K) |
(-20 to 750¡ÆC) |
(-20 to 750¡ÆC) |
(-20 to 750¡ÆC) |
|
(-20 to 750¡ÆC) |
Temperature |
— |
— |
— |
-4 to 518¡ÆF |
-4 to 518¡ÆF |
(InfraRed) |
|
|
|
(-20 to 270¡ÆC) |
(-20 to 270¡ÆC) |
Diode/Continuity |
Yes |
Yes |
Yes |
Yes |
Yes |
CAT Rating |
CAT III-600V |
CAT III-600V |
CAT III-600V |
CAT III-600V |
CAT III-600V |
Catalog No. |
Description |
Price |
EH410 |
Manual Ranging DMM |
89,964 |
EH411 |
True RMS Manual Ranging DMM |
126,684 |
EH430 |
True RMS Autoranging DMM |
163,404 |
EH450 |
Autoranging DMM+IR Thermometer |
200,124 |
EH470 |
True RMS DMM+IR Thermometer |
211,140 |
EH1194143 |
Vinyl Pouch Carrying Case |
34,884 | | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
|
|