Ç¥ÁØÇü: 9,000,000¿ø, Deluxe Documenting High Pressure Portable Pneumaric Calibrator : 9,700,000¿ø |
Portable High Pressure Pneumatic Calibrators |
|
|
Click to enlarge |
| |
|
|
|
|
The Portable High Pressure Pneumatic Calibrators Series is designed to make testing and calibration of high pressure instruments and systems both quick and simple. Two versions are available, the standard model and the deluxe which has full documenting capability. These self-contained portable calibrators provide unparalleled accuracy and control performance. A built-in gas cylinder provides source pressures up to 3000 psi, a precision pressure regulator and fine volume adjuster ensures optimum control and a digitally characterized sensor measures pressure to better than 0.025% of full scale.
¡¡ FEATURES
- Pressure units - 25 scale units plus one user defined
- mA source - Auto10-sec. step cycle and programmable (60 sec. end to end) ramp
- Process functions - Filter, max/min, tare, flow, and % span
- Power management - Auto power OFF, auto backlight OFF, battery status indicator
- Display - 2.36 x 2.36 inches graphic LCD with backlight. +/-99999 readout, 2 reading per second
- Data Storage - 92 kbytes memory
- High accuracy 0.025% FS
- Generates pneumatic pressures to 3000 psi
- Dual channel readout: pressure and electrical
- Self contained rechargeable gas cylinder
- RS 232 interface and documenting versions
- Coarse/fine adjust selection
|
| SPECIFICATIONS
The Calibrators include a built-in pressure sensor and matched pressure regulator. The pressure range should be selected from the table below. |
Pressure Range |
Accuracy* (% F.S.) |
Max. Overpressure |
Type** |
500 psi |
0.025% |
1000 psi |
G or A |
1000 psi |
0.025% |
2000 psi |
G or A |
1500 psi |
0.025% |
3000 psi |
G or A |
2000 psi |
0.025% |
4000 psi |
G or A |
3000 psi |
0.025% |
6000 psi |
G or A |
*Combined non-linearity, hysteresis and repeatability. **G = Gage, A = Absolute (pressure reference). |
Temperature Effects (averaged and w.r.t. 68¡ÆF) |
0.002% of rdg/¡ÆF. |
Pressure source |
Built-in Nitrogen/Air cylinder, (max refill pressure 3000psi). Storage volume 122 cubic inches. Capacity 14.0 cubic feet. |
Recommended media |
Oxygen Free Nitrogen (OFN). |
Remote Pressure Sensors |
Please consult factory for list. |
Electrical |
In addition to pressure, the dual display can simultaneously monitor mA, V, switch, continuity and ambient temperature. Also, 10Vd.c. and 24Vd.c. power supplies are available for the Device Under Test. |
Input |
Range |
Accuracy |
Resolution |
Remarks |
Voltage* |
¡¾50Vd.c. |
0.05% Rdg 0.004% F.S. |
100 microVmax |
Autoranging>10MW |
Current* |
¡¾55mA |
0.05% RDG 0.004% F.S. |
0.001mA |
10W, 50V max. |
Temperature |
15¡ÆF to 105¡ÆF |
¡¾2¡ÆF |
0.1¡ÆF |
Case ambient |
Switch |
Open/Closed |
|
|
5mA whetting |
Output |
Range |
Accuracy |
Resolution |
Remarks |
Voltage |
10Vd.c. |
0.1% |
|
Max. load 10mA |
Voltage |
24Vd.c. |
5% |
0.001mA |
Max. load 26mA |
Current* |
0 to 24mA |
0.05% Rdg 0.01% F.S. |
|
|
*Temperature coefficient 0.004% reading/¡ÆF w.r.t. 68¡ÆF |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
|
|
DR320500 |
|
DPI-320 |
|
500 psi gauge or absolute, Standard High Pressure Portable Pneumatic Calibrator |
|
|
|
9,592,000
| |
¡¡ |
Standard models include built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3201000 |
|
DPI-320 |
|
1000 psi gauge or absolute, Standard High Pressure Portable Pneumatic Calibrator |
|
|
|
9,592,000
| |
¡¡ |
Standard models include built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3201500 |
|
DPI-320 |
|
1500 psi gauge or absolute, Standard High Pressure Portable Pneumatic Calibrator |
|
|
|
9,592,000
| |
¡¡ |
Standard models include built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3202000 |
|
DPI-320 |
|
2000 psi gauge or absolute, Standard High Pressure Portable Pneumatic Calibrator |
|
|
|
9,592,000
| |
¡¡ |
Standard models include built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3203000 |
|
DPI-320 |
|
3000 psi gauge or absolute, Standard High Pressure Portable Pneumatic Calibrator |
|
|
|
9,592,000
| |
¡¡ |
Standard models include built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR325500 |
|
DPI-325 |
|
500 psi gauge or absolute, Deluxe Documenting High Pressure Portable Pneumatic Calibrator |
|
In Stock |
|
10,320,000
| |
¡¡ |
Deluxe documenting version includes built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3251000 |
|
DPI-325 |
|
1000 psi gauge or absolute, Deluxe Documenting High Pressure Portable Pneumatic Calibrator |
|
|
|
10,320,000
| |
¡¡ |
Deluxe documenting version includes built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3251500 |
|
DPI-325 |
|
1500 psi gauge or absolute, Deluxe Documenting High Pressure Portable Pneumatic Calibrator |
|
|
|
10,320,000
| |
¡¡ |
Deluxe documenting version includes built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3252000 |
|
DPI-325 |
|
2000 psi gauge or absolute, Deluxe Documenting High Pressure Portable Pneumatic Calibrator |
|
|
|
10,320,000
| |
¡¡ |
Deluxe documenting version includes built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ |
DR3253000 |
|
DPI-325 |
|
3000 psi gauge or absolute, Deluxe Documenting High Pressure Portable Pneumatic Calibrator |
|
|
|
10,320,000
| |
¡¡ |
Deluxe documenting version includes built-in rechargeable gas cylinder, rechargeable battery pack and charger, calibration certificates, test leads and manual. |
|
¡¡ | | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|