                    (0)                     (0)                     (0)
Dual input thermometer

GE Druck DPI 820

Dual input thermometer


¡¡
GE Druck DPI 820
GE Druck DPI 820

The GE Druck DPI 820 dual input thermometer consists of two sensor inputs, T1 and T2, which allow individual measurements or simultaneous comparisons. For differential applications; e.g. heating boiler bypass, T1 minus T2 can be displayed. The DPI 820 thermometer has interchangeable probes and wide thermocouple compatibility to provide general temperature measurement. In addition, the use of special sensors enables use in demanding applications; e.g. high temperature, hygienic, and aggressive media.

The sophisticated electronics in the DPI 820 thermometer makes it easy for the user to log and review data either onscreen or through a PC via RS232 interface.

Applications for the GE Druck DPI 820 Thermometer
  • Temperature test and measurement
  • Batch sampling and environmental monitoring
  • Comparison test against reference sensor
  • Laboratory standard

The DPI 820 thermometer contains multiple advanced features to increase its versatility and reliability:

IDOS "Plug and Play" Port

Every DPI 820 dual input thermometer has an IDOS (Intelligent Digital Output Sensor) compatible port for connecting remote IDOS measurement modules. For example, a DPI 820 can become a fully functional pressure calibrator by adding a universal pressure module. IDOS measurement modules are interchangeable between any IDOS compatible instruments without calibration or set-up. They are true "plug and play" modules.

Advanced Features

Advanced features of these dual input thermometers from the Druck DPI 820 series include hold, maximum/minimum/average, (with time stamp), tare (offset), and damping filter, which facilitates system checks and troubleshooting.

Data Logging
  • Memory: 1000 single or 750 dual reading screens with date and time
  • Header Tag: 6 user characters to identify groups of readings
  • RS232: 19.2 k baud, 8 data bits, 1 stop bit, no parity, Xon/Xoff
  • Data Output: Comma separated ASCII
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ