ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > ¿Âµµ/¾Ð·Â/½Àµµ/Àü±â ±³Á¤±â > Druck ¾Ð·Â ±³Á¤±â

DPI 880 ´Ù±â´É ±³Á¤±â
    ¡¤ °í°´¼±È£µµ :
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Humidity Sensors FK80J<br>Humidity-Temperature Sensors TFK80JPDF Ä«´Ù·Î±×

¡¡

GE Druck DPI 880

Portable multi-function calibrator


¡¡
GE Druck DPI 880
GE Druck DPI 880

Ultra-compact and simple-to-use, the GE Druck DPI 880 multi-function calibrator tests, configures, and calibrates virtually all process parameters. The DPI 880 is 35% smaller than competitive models and its Windows-like menu-driven display means fewer keys and simpler, easier-to-understand interface. The Druck DPI 880¡¯s data logging capability means that users no longer need to carry additional recording tools.

The Druck DPI 880 multi-function calibrator is virtually a calibration lab in the palm of your hand. The DPI 880 allows the user to obtain high precision data and address any issue in as much time as it takes to press a button, saving valuable operating time. For example, the DPI 880 can accurately test switches, trips, and alarms and print the results in 5 minutes, while a traditional device would take up to 40 minutes and would require manual data entry. Thermocouple transmitter calibrations may take up to an hour using a conventional (older, more dated) tool that requires the use of look-up tables. The GE Druck DPI 880 multi-function calibrator is capable of providing the ready to print results in just 5 minutes.

The DPI 880 measures and sources milliamps, millivolts, volts, ohms, frequency, thermocouples, RTDs, pulses, and pressure, captures switch values and provides 24 volt loop power. As such, the DPI 880 multi-function calibrator is a powerful tool for testing, configuring, and calibrating virtually any process parameter. Dual readings of both input and output parameters simplify calibration and system diagnostics, reducing the amount of service time required by technicians.

The GE Druck DPI 880 shares common features with the other DPI 800 Series models including a large, bright, backlit, full graphic display for easy reading in poor lighting conditions. Users benefit from the full graphic capability of the screen that creates multi-level readings and in depth reports. The rubberized exterior makes this multi-function calibrator an outstandingly robust device in rugged process field conditions that wear other meters out before their time. The calibrator has a built-in Hart¢ç loop resistor which alleviates the need to add an inline resistor when calibrating Hart devices.

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ