Features
  • Simulate RTD Temperature Outputs
  • Several RTD curves available - Plantinum, Cooper & Nickel
  • Guaranteed to work woth all pulsed instruments
  • Also compatible with devices using excitation currents like PLCs, DCS, Recorders and others
  • Works with a variety of transmitters including Rosemount & Honeywell models
 
 
SPECIFICATIONS
Display

¡¡

Backlit, 100mm, Color, 1/4 VGA transmissive display perfect for most indoor environments
Dimensions Front panel: 135 x 240mm; Depth: 245mm
Weight 4kg
Power Rechargeable Battery, life 10 hours typical with backlight
Wavelength 850nm¡¾ 20nm (Loss calibrated to 850nm)
Pulse Width 4 nanosecond (0.4 meter)
Fiber types 62.5um or 50um; multimode graded index
Max. Fiber Length 2km
Resolution Fresnel events <1m apart (¡¾ meter location accuracy)
Dynamic Range >13dB of fiber loss (256 averages where S/N = 1)
Group Index User-adjustable between 1.2 – 2.5
Event/ Attenuation Dead-zone <1m / <4m.
(As with all OTDRs, deadzone parameters are very dependent on the event reflectance. The Telcordia definition is used.)
 Connection is made to the unit using an IEC or TIA compliant mode-conditioning patchcord box fitted with an SC connector. Connection from the patchcord box to the fiber being tested is through a (user specified) Sc FC or ST connector.

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
PR5101   510-Pt100-1   Pt100 Single RTD Curve (alpha = 1.3850)   Yes   605,880
PR5102   510-Pt100-2   Pt100 Single RTD Curve (alpha = 1.3902)   Yes   605,880
PR5103   510-Pt100-3   Pt100 Single RTD Curve (alpha = 1.3916)   Yes   605,880
PR5104   510-Pt100-4   Pt100 Single RTD Curve (alpha = 1.3926)   Yes   605,880
PR5105   510-Cu10   Cu10 Single RTD Curve   Yes   Call 031-777-1588
PR5106   510-Ni70   Ni70 Single RTD Curve   Yes   Call 031-777-1588
PR5107   510-Ni120   Ni120 Single RTD Curve   Yes   Call 031-777-1588
PR511   511   7 RTD Curve Simulator plus Resitance   Yes   916,164
Custom units available - Please call to inquire.
PR0201   ¡¡ ¡¡ OPTIONAL Carrying Case FOR RTD Simulators   Yes   91,800
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ