ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¿Âµµ Temperature
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ML29123 Thermocouple Calibrator
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The ML29123 Thermometer/Thermocouple Calibrator provides the functions of both a Type K thermometer and Type K thermocouple calibrator. The ML29123 features a wide -199 to +1230 ¡ÆC (-325 to +2246 ¡ÆF) measurement and calibration range.
 
Features
  • Two-in-one meter: Type K thermometer & Type K thermocouple
  • Wide range: -199 to +1230 ¡ÆC (-325 to +2246 ¡ÆF)
  • Built-in, high precision, temperature linearity compensation circuit
  • ¡ÆC & ¡ÆF select & data hold functions for temperature measurement
  • ¡ÆC & ¡ÆF button selection for temperature calibration
  • Temperature measuring input to meet any standard Type K (NiCr-NiAl) probe
  • Fitted with standard Type K mini-plug socket
  • Large LCD display
  • Operates on 006P DC 9V battery
  • RS232 PC serial computer interface
 
 
SPECIFICATIONS
(23 ¡ÆC ¡¾5 ¡ÆC; specifications are tested under the environment RF Field Strength < 3V/M and frequency <30 MHz)
Display LCD display with 13 mm
(0.5) digit size
Measure/Calibration Range -199 to +1230 ¡ÆC /-325 to +2246 ¡ÆF

Thermometer
Sensor Type
Input Impedance


Thermocouple K (NiCr-NiAl)
10 MegOhm

Sampling Time Approx. 0.4 seconds
Data Output RS232 PC serial computer interface
Overall Accuracy ¡¾(1 % ¡¾ 2 ¡ÆC) / ¡¾(1 % + 5 ¡ÆF) max.
Operating Temperature 0 to 50 ¡ÆC (32 to 122 ¡ÆF)
Operating Humidity Less than 80% RH
Power Supply 9V DC battery
Weight 280 g /0.62 LB (with battery)
Dimensions 185 x 78 x 38 mm (7.3 x 3.0 x 1.5 inch)
 Notes:
1. The accuracy specification of the thermometer applies only to the instrument itself and does not include T/C errors.

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
ML29123   LTC-920   Thermocouple Calibrator   Yes   438,804
ML29114   LCA-05A   OPTIONAL Carrying Case FOR Thermometer/Thermocouple Calibrator   Yes   33,048

 

ML29121   LSW-U101   OPTIONAL Windows Software FOR Thermometer/Thermocouple Calibrator   Yes   86,292

 

ML29122   LUPCB01   OPTIONAL RS232 Cable FOR Thermometer/Thermocouple Calibrator   Yes   40,392

 

ML29115   TP-K01   OPTIONAL Bead Probe FOR Thermometer/Thermocouple Calibrator   Yes   16,524

 

ML29116   TP-K02   OPTIONAL Immersion Probe FOR Thermometer/Thermocouple Calibrator   Yes   73,440

 

ML29117   TP-K03   OPTIONAL Surface Probe FOR Thermometer/Thermocouple Calibrator   Yes   104,652

 

ML29118   TP-K04   OPTIONAL Piercing Probe FOR Thermometer/Thermocouple Calibrator   Yes   104,652

 

ML29119   TP-K05   OPTIONAL Surface Probe FOR Thermometer/Thermocouple Calibrator   Yes   152,388

 

ML29120   TP-K06   OPTIONAL Air and Gas Probe FOR Thermometer/Thermocouple Calibrator   Yes   111,996

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ