This Precision Temperature Calibrator is an ideal device to handle all of your temperature calibration needs in a truly rugged, low cost package. It combines virtually all widely used thermocouples and RTDs in one device—you¡¯ll never have to worry about finding a temperature device you can¡¯t calibrate. This is especially true when calibrating ¡°smart¡± or pulsed RTD transmitters where many other calibrators fail to work or operate at reduced accuracy specs. The unit handles those applications with ease. |
|
Features |
- High accuracy ¡¾0.4¡ÆC and ¡¾0.3¡ÆC RTD all errors included
- 10 T/C types and 8 RTD types including PT 385 (1000 ohm) and CU (10 ohm)
- Direct keyboard entry or scroll control of output
- NEMA 4 rated case, rugged design
- RTD simulation works with all pulsed (smart transmitters)
- YSI 400 series thermistor range for medical application
- Standard mini-plug or banana jack connections for T/C
- Store up to nine setpoints for each output function
- RS232 Interface
- Thermocouple & RTD Capability in one unit
- Works with Rosemont 3144 and all other "smart" transmitters
- Each unit includes: Test leads, rubber boot, 4 AA alkaline batteries, NIST Certificate and instruction manual
|
| | SPECIFICATIONS
T/C Ranges |
J, K, T, E, R, S, N, B, L, U including -10 to 70 nmV range |
RTD Ranges |
Pt 385 (100, 200, 500, 1000 ohms) |
Pt392, JIS, Ni, 120, CU10, YSI 400 |
Ohms Ranges |
0 to 400.00 and 400.00 to 4000.0 |
Accuracy |
T/C Type J: ¡¾.3¡ÆC ¡¾10¥ì |
V (¡¾0.6¡ÆC total error) |
RTD PT100: ¡¾.1¡ÆC ¡¾ .075 ¥Ø |
(¡¾0.3¡ÆC total error) |
Ohms (400): ¡¾0.1¥Ø |
Ohms (4000): ¡¾1.0¥Ø |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
ML3820011 |
|
PTC-8000 |
|
TEMPERATURE CALIBRATOR |
|
Yes |
|
1,826,820 |
ML80029 |
|
80029 |
|
OPTIONAL THERMOCOUPLE CABLE KIT FOR High Accuracy Temperature Calibrator |
|
Yes |
|
181,764 |
Kit includes: Type J T/C Cable, Type K T/C Cable, Type T T/C Cable and Type E T/C Cable All cables are terminated with a standard mini-connector on one end and bare leads on the other. |
ML02 |
|
10077 |
|
OPTIONAL "AA" NICAD BATTERY (SOLD EACH) FOR High Accuracy Temperature Calibrator |
|
Yes |
|
15,606/font>
|
ML342103 |
|
1001-9V |
|
OPTIONAL AC ADAPTOR FOR High Accuracy Temperature Calibrator |
|
Yes |
|
40,392 | | |
|
|
| |
|