ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¿Âµµ Temperature
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ML3820011 High Accuracy Temperature Calibrator
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
This Precision Temperature Calibrator is an ideal device to handle all of your temperature calibration needs in a truly rugged, low cost package. It combines virtually all widely used thermocouples and RTDs in one device—you¡¯ll never have to worry about finding a temperature device you can¡¯t calibrate. This is especially true when calibrating ¡°smart¡± or pulsed RTD transmitters where many other calibrators fail to work or operate at reduced accuracy specs. The unit handles those applications with ease.
 
Features
  • High accuracy ¡¾0.4¡ÆC and ¡¾0.3¡ÆC RTD all errors included
  • 10 T/C types and 8 RTD types including PT 385 (1000 ohm) and CU (10 ohm)
  • Direct keyboard entry or scroll control of output
  • NEMA 4 rated case, rugged design
  • RTD simulation works with all pulsed (smart transmitters)
  • YSI 400 series thermistor range for medical application
  • Standard mini-plug or banana jack connections for T/C
  • Store up to nine setpoints for each output function
  • RS232 Interface
  • Thermocouple & RTD Capability in one unit
  • Works with Rosemont 3144 and all other "smart" transmitters
  • Each unit includes: Test leads, rubber boot, 4 AA alkaline batteries, NIST Certificate and instruction manual
 
SPECIFICATIONS

T/C Ranges

J, K, T, E, R, S, N, B, L, U including -10 to 70 nmV range
RTD Ranges Pt 385 (100, 200, 500, 1000 ohms)
Pt392, JIS, Ni, 120, CU10, YSI 400
Ohms Ranges 0 to 400.00 and 400.00 to 4000.0
Accuracy T/C Type J: ¡¾.3¡ÆC ¡¾10¥ì
V (¡¾0.6¡ÆC total error)
RTD PT100: ¡¾.1¡ÆC ¡¾ .075 ¥Ø
(¡¾0.3¡ÆC total error)
Ohms (400): ¡¾0.1¥Ø
Ohms (4000): ¡¾1.0¥Ø

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
ML3820011   PTC-8000   TEMPERATURE CALIBRATOR   Yes   1,826,820
ML80029   80029   OPTIONAL THERMOCOUPLE CABLE KIT FOR High Accuracy Temperature Calibrator   Yes   181,764
Kit includes: Type J T/C Cable, Type K T/C Cable, Type T T/C Cable and Type E T/C Cable All cables are terminated with a standard mini-connector on one end and bare leads on the other. 
ML02   10077   OPTIONAL "AA" NICAD BATTERY (SOLD EACH) FOR High Accuracy Temperature Calibrator   Yes   15,606/font>

 

ML342103   1001-9V   OPTIONAL AC ADAPTOR FOR High Accuracy Temperature Calibrator   Yes   40,392
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ