DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
| |
Choice of thermometer or process calibration cable (5'). Thermometer calibration cable has molded subminiature connectors for use with other thermometers and comes standard with the meter. The process calibration cable is terminated with spade lugs for connection to controllers, transmitters and recorders. To substitute process cable with meter, add ¡°P¡± to end of part number. |
|
Features |
- One model for multiple thermocouple types
- Microprocessor assures maximum accuracy to 0.15% of reading over wide ranges
- 0.1¡Æresolution,¡ÆC/¡ÆF switchable
- Provides precision and convenience equal to more expensive calibrators
- Bright 4 digit LED display is easy to read
- LED indication of sensor type
- Complete with thermometer calibration cable with subminiature connectors, 9 volt NiCad rechargeable battery and AC adapter/recharger
- Displays output in terms of millivolts or temperature based on thermocouple tables
|
| | SPECIFICATIONS
|
Ranges for Calibrate and Measure modes |
Accuracy |
Type J |
-58¡Æ to 1630¡ÆF |
(-50¡Æ to 1370¡ÆC) |
0.15% reading |
Type K |
-58¡Æ to 2496¡ÆF |
(-50¡Æ to 1370¡ÆC) |
0.15% reading |
Type T |
-184¡Æ to 752¡ÆF |
(-120¡Æ to 400¡ÆC) |
0.15% reading |
Type E |
-58¡Æ to 1382¡ÆF |
(-50¡Æ to 750¡ÆC) |
0.15% reading |
Type C |
32¡Æ to 3272¡ÆF |
(0¡Æ to 1800¡ÆC) |
0.15% reading |
Type R |
32¡Æ to 3182¡ÆF |
(0¡Æ to 1750¡ÆC) |
0.15% reading |
Type S |
32¡Æ to 3182¡ÆF |
(0¡Æ to 1750¡ÆC) |
0.15% reading |
Type N |
-5¡Æ8 to 2372¡ÆF |
(-50¡Æ to 1300¡ÆC |
0.15% reading |
Resolution |
0.1¡Æ up to 999.9¡Æ; 1¡Æ 1000¡Æ+ |
Cold Junction Compensation |
0.03¡ÆC/¡ÆC (0.02¡ÆF/¡ÆF) |
Input Impedance |
10M¥Ø |
Sampling Time |
4 times/seconds |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
EH139486 |
|
433201 |
|
MICROPROCESSOR CALIBRATOR/ THERMOMETER 115VAC |
|
Yes |
|
688,500
|
EH4314375 |
|
431437 |
|
OPTIONAL Process calibrator cable with spare lugs FOR Thermocouple Calibrator / Thermometer |
|
Yes |
|
33,048
|
EH4099965 |
|
409996 |
|
OPTIONAL Vinyl pouch carrying case FOR Thermocouple Calibrator / Thermometer |
|
Yes |
|
34,884
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
|
|