ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > DAVIS (»óÇ° 25000°³) > ±³Á¤±â Calibrators > ¿Âµµ Temperature
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
EH139486 Microprocessor Calibrator Thermometer
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Choice of thermometer or process calibration cable (5'). Thermometer calibration cable has molded subminiature connectors for use with other thermometers and comes standard with the meter. The process calibration cable is terminated with spade lugs for connection to controllers, transmitters and recorders. To substitute process cable with meter, add ¡°P¡± to end of part number.
 
Features
  • One model for multiple thermocouple types
  • Microprocessor assures maximum accuracy to 0.15% of reading over wide ranges
  • 0.1¡Æresolution,¡ÆC/¡ÆF switchable
  • Provides precision and convenience equal to more expensive calibrators
  • Bright 4 digit LED display is easy to read
  • LED indication of sensor type
  • Complete with thermometer calibration cable with subminiature connectors, 9 volt NiCad rechargeable battery and AC adapter/recharger
  • Displays output in terms of millivolts or temperature based on thermocouple tables
 
SPECIFICATIONS
 

Ranges for Calibrate and Measure modes

Accuracy
Type J

-58¡Æ to 1630¡ÆF

(-50¡Æ to 1370¡ÆC)

0.15% reading

Type K

-58¡Æ to 2496¡ÆF

(-50¡Æ to 1370¡ÆC)

0.15% reading

Type T

-184¡Æ to 752¡ÆF

(-120¡Æ to 400¡ÆC)

0.15% reading

Type E

-58¡Æ to 1382¡ÆF

(-50¡Æ to 750¡ÆC)

0.15% reading

Type C

32¡Æ to 3272¡ÆF

(0¡Æ to 1800¡ÆC)

0.15% reading

Type R

32¡Æ to 3182¡ÆF

(0¡Æ to 1750¡ÆC)

0.15% reading

Type S

32¡Æ to 3182¡ÆF

(0¡Æ to 1750¡ÆC)

0.15% reading

Type N

-5¡Æ8 to 2372¡ÆF

(-50¡Æ to 1300¡ÆC

0.15% reading

Resolution 0.1¡Æ up to 999.9¡Æ; 1¡Æ 1000¡Æ+
Cold Junction Compensation 0.03¡ÆC/¡ÆC (0.02¡ÆF/¡ÆF)
Input Impedance 10M¥Ø
Sampling Time 4 times/seconds

CAT NO. MODEL DEscRIPTION AVAIL PRICE 
EH139486   433201   MICROPROCESSOR CALIBRATOR/ THERMOMETER 115VAC   Yes   688,500

 

EH4314375   431437   OPTIONAL Process calibrator cable with spare lugs FOR Thermocouple Calibrator / Thermometer   Yes   33,048

 

EH4099965   409996   OPTIONAL Vinyl pouch carrying case FOR Thermocouple Calibrator / Thermometer   Yes   34,884

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ