The ISOCAL 6 is the only calibration system in the world (Patent application 9900158.8) to offer you six calibration baths in one product. It is a complete temperature calibration laboratory in one simple easy-to-use package. It is designed to expand with you to fulfill all of your future calibration needs while giving you the flexibility to meet your current budgetary demands.
The ISOCAL 6 can calibrate temperature sensors absolutely or by comparison. It will calibrate contact and non-contact sensors including infrared thermometers, surface sensors, mercury in glass thermometers, as well as thermocouples, RTDs, and thermistors of any shape.
There are three different models covering a total temperature range of -65¡ÆC below ambient to 250¡ÆC. The ISOCAL 6 has interchangeable inserts to give you the most flexible calibration system ever, with unprecedented accuracies from ¡¾0.001¡ÆC with fixed point apparatus. |
| SPECIFICATIONS
Temperature Range |
SERIES V |
-55¡ÆC below ambient to 140¡ÆC (284¡ÆF) |
SERIES C |
Ambient to 250¡ÆC (482¡ÆF) |
SERIES E |
-65¡ÆC below ambient to 140¡ÆC (284¡ÆF) |
Stabilities over 30 minutes |
Metal Block Bath |
¡¾0.03¡ÆC |
Stirred Liquid Bath |
¡¾0.025¡ÆC |
Ice/Water Bath |
¡¾0.001¡ÆC |
Black Body Source |
¡¾0.3¡ÆC |
Surface Sensor Calibrator |
¡¾0.5¡ÆC |
ITS-90 Fixed Point |
Mercury Triple Point |
¡¾0.0005¡ÆC at -38.8344¡ÆC |
Water Triple Point |
¡¾0.00025¡ÆC at 0.01¡ÆC |
Gallium Melt Point |
¡¾0.00025¡ÆC at 29.7646¡ÆC |
Indium Melt Point |
¡¾0.0005¡ÆC at 156.59850¡ÆC |
Stabilization Time |
10 minutes |
Calibration Volume |
1-3/8" diameter x 6-1/4" deep |
Uniformity |
¡¾0.018¡ÆC |
Controller Resolution |
0.1¡Æ |
Indicator Resolution |
0.1¡Æ to 0.01¡Æ |
Indicator Units |
¡ÆC, ¡ÆF, ¡ÆK |
Overall Dimensions |
12" x 7" x 11" |
Weight |
23 lbs |
Power |
70V AC or 240V AC (specify) |
CAT NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
TT60108 |
|
VENUS-2140-B+ |
|
ISOCAL 6 , -55¡ÆC below ambient to 140¡ÆC (284¡ÆF), basic version, with RS232 & software |
|
Yes |
|
9,354,420 |
TT60109 |
|
VENUS-2140-S+ |
|
ISOCAL 6 , -55¡ÆC below ambient to 140¡ÆC (284¡ÆF), site version, with RS422 & software |
|
Yes |
|
10,463,364 |
TT6070 |
|
CALISTO-2250-B+ |
|
ISOCAL 6 , 30¡ÆC to 250¡ÆC (482¡ÆF), basic version, with RS232 & software |
|
Yes |
|
6,607,764
|
TT60111 |
|
CALISTO-2250-S+ |
|
ISOCAL 6 , 30¡ÆC to 250¡ÆC (482¡ÆF), site version, with RS422 & software |
|
Yes |
|
7,525,764
|
TT60112 |
|
EUROPA-3140-S+ |
|
ISOCAL 6 , -65¡ÆC below ambient to 140¡ÆC (284¡ÆF), site version, with RS422 & software |
|
Yes |
|
12,668,400 |
TT60113 |
|
ISO6-INS-L |
|
OPTIONAL Standard liquid container for ISOCAL 6 (alcohols, water, or oils) FOR Calibration Laboratory |
|
Yes |
|
541,620
|
TT60114 |
|
ISO6-INS-B |
|
OPTIONAL Blackbody target for ISOCAL 6 FOR Calibration Laboratory |
|
Yes |
|
275,400
|
TT60115 |
|
ISO6-INS-SK |
|
OPTIONAL Standard surface sensor calibration insert for ISOCAL 6 FOR Calibration Laboratory |
|
Yes |
|
504,900
|
TT60116 |
|
¡¡ |
¡¡ |
OPTIONAL I-Cal Calibration Software FOR Calibration Laboratory |
|
Yes |
|
1,377,000
| | |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|