ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > µ¥ÀÌÅͷΰŠ¹× ±â·Ï°è > Grant Á¦Ç°

Squirrel SQ1000 16ch Data Logger
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : Grant
    ¡¤ ½ÃÁß°¡°Ý : ¿ø
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
Humidity Sensors FK80J<br>Humidity-Temperature Sensors TFK80J PDF Ä«´Ù·Î±×

¡¡
¡¡
¡¡

For a wide range of applications
Versatile 1000 Series Squirrel meter/dataloggers connect to a very wide range of sensors, transducers and meters to provide considerable flexibility for numerous monitoring applications.

SQ1000 : analog input: 8ch (¿É¼Ç: 16ch) ¿Âµµ/½Àµµ/¾Ð·Â/Àü¾Ð/Àü·ù, digital pulse : 1ch, event/digital count: 8ch

12bit resolution, ¡¾0.2% accuracy: 2M memory, 99 logger run °¡´É

Versatile Squirrel 1000 Series dataloggers connect to a very wide range of sensors, transducers and meters to provide considerable flexibility.
  • Portable, battery operated
  • Factory configured with the user's choice of temperature and voltage/current inputs
  • Pulse count channel
  • Eight event/digital channels
  • Standard 64k reading non-volatile memory
  • Easy set up either manually or by PC
  • Foreign language versions
  • Download to PC at 19.2kbaud, remotely via modem for unattended monitoring

Options
Internal memory 260k, 500k, 1M or 2M readings
PCMCIA slot
Alarm outputs
Customised input channel name and configuration

Software
DARCA
SQREM
Taskwise
Filewise for Windows
Squirrelwise for Windows

Squirrel 1000 Series PDF

¡¡

Squirrel Dataloggers For Energy Management

1010 Model Squirrel   1020 Model Squirrel

Squirrel Data Logger
1010 Model

 

Squirrel Data Logger
1020 Model

The 1010 and 1020 Model Squirrel data loggers have been specifically designed for the Energy Management / Electricity market.

View the Energy Squirrels Datasheet (pdf format) for comprehensive information.

Squirrel Model Channel Configuration
(Number and type of sensor)
Modules Used Case depth mm
1010* 6 AC Voltage+ 2 Thermistor / AC Voltage M10 60
1020* 12 AC Voltage + 4 Thermistor / AC Voltage M10 x 2 85

Sensors For Energy Management

Eltek produce and stock a range of Transducers tailored for the Energy industry.

Eltek Squirrel data loggers, when used with Eltek supplied transducers and sensors, display readings in the appropriate engineering unit e.g. Volts / Amps - no units conversion is necessary.

Eltek Transducers for Energy measurement:

  Squirrel Input
RC1000 Rogowski Coil - Current Transducer AC Input
VTS270 Voltage Transducer AC Input
CT5 5 Amp Current Clamp AC Input
CT75 7.5 Amp Current Clamp AC Input
CS-U-V2-DIN Temperature Probe U Input

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ