Simple Logger¢ç is a single channel, low cost Datalogger that
requires no user setup. It has the ability to automatically adjust both
its scale range and its sample rate to optimize the recording session.
Simple Logger¢ç includes a Windows¢ç based software package that
can plot, analyze recording data and print graphs and data listings.
The main advantage
of Simple Logger¢ç is its ability to perform a wide variety of
recording tasks with high resolution and accuracy without the need for
user setup. It achieves this by means of automatic scaling and Time
Extension Recording¢â (TXR¢â) along with a flexible input
design.
Simply connect the
logger to the signal to be recorded and press the button to begin
recording. When the session is complete press the button to stop. It is
that simple!
|
Features
|
- No user setup
required — one button operation
- Log and measure
Amps rms, Volts rms, Temperature, DC Volts, DC Amps
- Autosampling up
to 4096/hr — provides for maximum information
- Stores over
8000 readings
- Auto-scaling
— provides for optimum resolution for the recording session
- Innovative Time
Extensive Recording¢â (TXR¢â) technique provides
continuous recording for any length of time without user setup
- Low power
— records for up to one year using a 9V Alkaline battery
|
Software
Features
|
- Windows¢ç
based graphing and analysis software included with each Datalogger
- Statistics
appear on screen: Max, Min, Avg, Data and Time
- On-Line display
of Datalogger values
- Zoom capability
with automatic statistics update
- Export data to
spreadsheet and database applications
- Print both
graph and tabular listings
- Programmable
scale and units for all DC loggers Automatic selection for AC
loggers
|
Common
Features
|
- Sample rate:
4096/hr maximum
- Resolution: 8
to 12 bit
- Data storage:
8192 to 65,536 Readings (depending on model)
- Power: 9V
Alkaline battery
- Output: RS-232
via DB9 connector
- Indicator: Red
LED flashes once every 2 seconds in STANDBY mode, twice every 2
seconds in LOGGING mode, and is off in OFF mode
- Controls: One
membrane switch used to start and stop recording sessions and to
turn the Datalogger on and off
- Operating
Temperature: -4 to +158¡ÆF (-20 to +70¡ÆC)
- Storage
Temperature: -40 to +176¡ÆF (-40 to +80¡ÆC)
- Relative
Humidity: 5 to 95% non-condensing
|
Typical
Applications
|
- Machine load
monitoring
- Metering CT
re-sizing
- Temperature
monitoring
- HVAC
troubleshooting
- Computer room
monitoring
- Food
storage/Refrigerated freight
- Wave soldering
- Process control
monitoring
- Railroad signal
monitoring
- Surge/sag
monitoring
- Line
voltage/Stray voltage monitoring
- Load profiling
|
Model L100 0 to
1Vrms input 0 to 10,000Arms based on probe
Model L70 0 to 1Arms input 0 to 3,000Arms based on probe
AC Voltage Loggers
True RMS measurement with recessed safety banana jack inputs
Model L205 0 to 25Vrms input (stray voltage)
Model L230 0 to 300Vrms input
Model L260 0 to 600Vrms input
AC Exception Voltage
True RMS measurement to capture short term events such as sags,
swells and dropout connection via recessed safety banana jacks
Model L215 0 to 250Vrms
Plug-In AC Voltage Logger
Plugs directly into 120V wall outlet. Records line to neutral or
neutral to ground voltage — switch selectable
Model L220 0 to 255Vac
|
|
CAT
NO |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
AE916111 |
|
L100 |
|
Simple
Logger¢ç Model L100 (RMS Current, 0 to 1Vac Input) |
|
Yes |
|
551,514
|
AE916112 |
|
L70 |
|
Simple
Logger¢ç Model L70 (RMS Current, 0 to 1Aac Input) |
|
Yes |
|
551,514
|
AE211605 |
|
L205 |
|
Simple
Logger¢ç Model L205 (Stray Voltage w/Leads, 0 to 25.5Vac
Input) |
|
Yes |
|
645.840
|
AE916113 |
|
L230 |
|
Simple
Logger¢ç Model L230 (RMS Voltage w/Leads, 0 to 300Vac Input) |
|
Yes |
|
548,964
|
AE916114 |
|
L260
(2113.94) |
|
SIMPLE
LOGGER - RMS VOLTAGE MODULE L260 (0 - 600 VAC input) |
|
Yes |
|
548,964
|
All voltage Simple
Loggers are supplied with software (3 1/2" diskette), 6 ft.
DB9 RS-232 cable, 9 V battery, 5' lead set, and user manual |
AE211607 |
|
L215 |
|
Simple
Logger¢ç Model L215 (RMS Voltage, 0 to 250Vac Input) |
|
Yes |
|
640,764
|
AE211606 |
|
L220
(2113.95) |
|
SIMPLE
LOGGER AC VOLTAGE WITH INTEGRAL WALL PLUG MODEL L220 (VAC RMS) |
|
Yes |
|
548,964
|
All Simple Loggers are
supplied with software (3 1/2" diskette), 6 ft. DB9 RS-232
cable, 9 V battery and user manual |
|
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|