ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > °¡½ºÃøÁ¤±â > º¹ÇÕ°¡½º ÃøÁ¤±â

 
LMSxi
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : U.S.A
    ¡¤ ÆǸŰ¡°Ý : ÀüÈ­¹®ÀÇ

¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)

Ư ¡

 

* Infra-Red, CH4, CO2, O2, N2, ¿Âµµ, ´ë±â¾Ð µ¿½ÃÃøÁ¤

* NH3, H2S, CO, NO2, NO, SO2, HCN, gasµî ÃÖ´ë 7°¡Áö °¡½ºµ¿½ÃÃøÁ¤

* ¼³Ä¡ ¿¬¼Ó Monitoring ÃøÁ¤°¡´É

* Infra-Red ¼¾¼­ ä¿ëÀ¸·Î Á¤È®ÇÑ °¡½º ³óµµ Ç¥½Ã

* 1000°³ÀÇ ÃøÁ¤ Data ÀÚü ¸Þ¸ð¸®±â´É, ÄÄÇ»ÅÍ·Î downloading.

* ³»ÀåÆßÇÁ À¯·®Á¶Àý °¡´É

* ÀÚµ¿ ¼¼Á¤ ±â´É. (¼¾¼­¼ö¸í ¿¬Àå)

* ½Ç½Ã°£ °¡½º ºÐ¼®°¡´É, ¾Ë¶÷¼³Á¤°¡´É

* Æó±â¹° ¸Å¸³½Ã¼³ »çÈÄ°ü¸® ÀûÇÕ

* Á¶»çÇ׸ñ : °¡½º¿Âµµ, CH4, CO2, O2, N2, NH3, H2S, NOx

¿ë µµ

 

* Land fill gas (¸Å¸³Áö °¡½º) ºÐ¼®

* Çø±â¼º,È£±â¼º °¡½ººÐ¼®

* Ãà»ê ºÐ´¢ °¡½º ÃøÁ¤. ÅðºñÈ­ °øÁ¤.

* ¿ÀÆó¼ö ½½·¯Áö °¡½º ºÐ¼®

* Åä¾ç¿À¿° º¹¿ø Á¶»ç

* ¹Ì»ý¹° ¹ßÈ¿°¡½º, ¿ø¿¹ÀÛ¹°, ¿ø¿¹ÇÐ, ½Ä¹° Àç¹è.

LMSxi The Expandable Landfill Monitoring System

General

Ambient temp range

-10 to 40 ¡É

Battery life

10 hours typically

Aspiration rate

300 ml/min typically

Storage capacity

>900 readings

Protection rating

IP65

Dimensions

150 x 200 x 190 mm (approx.)

Weight

<2.0 Kg

Standard Channels

Gas Type

Range

Typical Accuracy

Typical Response

Methane(CH4)

0 to 100%

0.2% @ 5%

20s

1.0 % @ 30%

3.0 % @ 100%

0 to 100% LEL

4% LEL

30s

Carbon dioxide
(C02)

 0 to 100%

0.1% @ 10%

20s

3.0 % @ 50%

3% @ 100%

Oxygen(02)

0 to 25%

0.5 %

20s

Atmospheric Pressure

800 to 1200mbar

5mbar, 1 mbar resolution

20s

Standard Accessories

Battery charger, Carry case, Sample pipe & Filter, Manual, Calibration certificate


Optional Gas Channels (Maximum of 4) See Note 1

CO2

10000ppm

5% of fs

30s

H2S

200ppm

5% of fs

30s

CO

1000ppm

5% of fs

30s

NO2

20ppm

5% of fs

30s

SO2

100ppm

5% of fs

30s

HCN

100ppm

5% of fs

30s

Hydrocarbon Gas

%, LEL or ppm depending on compound.

% Relative Humidity

100%

5% of fs

30s


Other Optional  Channels

Type

Range

Typical Accuracy

Resolution

Differential pressure(low range)(See notes 2&3)

¡¾1000 Pa

2% of fs

1 Pa

Differentia pressure(high range)(See notes 2&3)

¡¾100 mbar

2% of fs

0.1 mbar (See note 4)

Temperature

- 10 to 60 ¡É

0.5 ¡É

0.1¡É

Flow Monitoring(See note 3)

Bore hole Flow & Pressure Expansion(low flow-Type 3 software)

 

Flow Range

+30/-10 l/hour

Flow Resolution

0.1 l/hour

Differential pressure

+300/-30 Pa(Typical)

Static Pressure

N/A

 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ