Data
Logger Features
|
- SRP1 -
TEMPERATURE - Two channels (one for internal temp. sensor
and one for remote temp. sensing or switch status or
resistance)
- SRP2 -
RELATIVE HUMIDITY - Four channels (one for internal temp.
sensor, one for RH sensor and two remaining for optional
remote sensing of temp, RH or resistance)
- SRP3 -
3 PHASE CURRENT - Four channels (one for ambient temp, and
three external for use with Amprobe clamp-on current probes)
- SRP5 -
2 CHANNEL THERMOCOUPLE - Three channels (one for internal
thermistor for cold- junction compensation and two
thermocouple inputs for types J, K, S or T)
- SRP6 -
7 CHANNEL THERMOCOUPLE - Eight channels (one for internal
thermistor for cold-junction compensation and seven
thermocouple inputs for types J, K, S or T) 0-10VDC or
0-25mADC
- SRP7 -
PROCESS SIGNAL - Eight channels (one for internal thermistor
and seven analog inputs) 4-20 mA or 0-1VDC
|
|
Software
Features
|
- Presentation
quality graphs
- One-Touch
table view
- Fast
and easy logger setup
- Exports
data to spreadsheets
|
|
|
SPECIFICATIONS
Size
|
107 x 74 x 22 mm
(4.2" x 2.9" x 0.9") |
Weight |
70 grams (3.75
ounces) |
Case Material |
Noryl¢ç Plastic |
Operating Limits |
-45¡ÆC to 70¡ÆC
(-50¡ÆF to 160¡ÆF) and 0 to 95% Relative Humidity (non-condensing) |
Clock Accuracy |
¡¾ 2 seconds per
day plus one sampling interval |
Battery |
3.6-volt Lithium, 1
Amp-Hour |
Memory Size |
32KB-21,500
readings; 128KB-87,000 readings |
Sampling
Methods |
1. Continuous
(First-in, First-out) Not available for sample rates faster than 8
seconds |
2. Stop when full
(Fill-then-stop) |
Sampling Rates |
User selectable
rates from 25 per second to every 8 hours (BP-100 battery pack required
for sample rates less than 8 seconds |
Resolution |
12 bit (1 part in
4096) |
Power Consumption |
5 to 10 microamps
(continuous) |
Battery Life |
Ten years (Factory
replaceable) |
PC Hardware
Requirements |
IBM PC or 100%
compatible with at least one free serial port |
Software
Requirements |
TrendReader¢ç
for Windows-Windows version 3.1, 95 or NT already running with at least
2 MB of RAM memory and 2 MB of hard disk space |
External Connector |
Removable
screw-type terminal strip with Common (-) connection |
Internal
Temperature Sensor (common on all models,except AR97001) |
Type |
Negative
Temperature Coefficient |
Thermistor10,000
ohms @ 25¡ÆC(77¡ÆF) |
Tolerance (sensor
only) |
¡¾ 0.2¡ÆC, over the
range of 0 to 70¡ÆC (¡¾ 0.3¡ÆF, over the range of 32 to 158¡ÆF) |
Range |
-40 to 70¡ÆC (-40
to 158F) |
Resolution |
0.03¡ÆC (0.05¡ÆF)
at 25¡ÆC (77¡ÆF) |
Better than 0.07¡ÆC
(0.12¡ÆF) between -25¡ÆC (-13¡ÆF) and 70¡ÆC (158¡ÆF) |
Better than 0.13¡ÆC
(0.23¡ÆF) between -40¡ÆC (-40¡ÆF) and -25¡ÆC (-13¡ÆF) |
CAT
NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
AR97001 |
|
+1/01-0112 |
|
TEMP. DATA
LOGGER W/ 128KB SMARTREADER PLUS 1 (01-0112) |
|
Yes |
|
1,090,584
|
AR97002 |
|
SMART+2/01-0113 |
|
TEMP/
RELATIVE HUM. DATALOGGERW/128 KB MEMORY |
|
Yes |
|
1,090,584
|
AR97003 |
|
SMART+3/01-0114 |
|
CURRENT/TEMP
DATA LOGGER W/128KB MEMORY |
|
Yes |
|
1,422,900
|
AR97055 |
|
01-0118 |
|
0-100PSIA
PRESS/TEMP DATALOGERW/128 KB MEMORY |
|
Yes |
|
1,650,564
|
AR97005 |
|
SMART+5 |
|
TEMPERATURE
DATA LOGGER W/128 KB MEMORY (01-0121) |
|
Yes |
|
1,606,500
|
AR97006 |
|
SMART+6/01-0122 |
|
MULTI-CHANNEL
TEMP DATA LOGGERW/128 KB MEMORY |
|
Yes |
|
2,026,944
|
AR97007 |
|
SMART+7
01-0123 |
|
PROCESS
SIGNAL DATA LOGGER W/128 KB MEMORY |
|
Yes |
|
1,834,164
|
AR97008 |
|
SMART+8/01-0129 |
|
8-Channel
Temperature Logger (128K) |
|
Yes |
|
1,650,564
|
AR720091 |
|
SRP-009 |
|
2-Channel
Pulse Logger (128K) |
|
Yes |
|
1,650,564
|
AR97010 |
|
SRP-010 |
|
3-Channel RTD
Temperature Logger (128K) |
|
Yes |
|
1,834,164
|
AR100120 |
|
AM-100-120 |
|
Alarm Module
for SRP Series |
|
Yes |
|
504,900
|
AR72020 |
|
TR-WIN-SRP |
|
OPTIONAL
TRENDREADER SOFTWARE FOR WINDOWS
TR-WIN-SRP(01-0072) FOR Smart Reader Plus Data
Loggers |
|
Yes |
|
324,644
|
Please
inquire for additional probes and sensors |
AR10076 |
|
TBS-WIN |
|
OPTIONAL
Talk back Software Package for automatic
download of data FOR Smart Reader Plus Data
Loggers |
|
Yes |
|
328,644
|
Please
inquire for additional probes and sensors |
AR10073 |
|
RTM-WIN |
|
OPTIONAL
Reat Time Graphing Software
FOR Smart Reader Plus Data Loggers |
|
Yes |
|
181,764
|
Please
inquire for additional probes and sensors |
AR72021 |
|
EH-020A
(01-0040) |
|
OPTIONAL
REMOTE TEMPERATURE & RH PROBE FOR
Smart Reader Plus Data Loggers |
|
Yes |
|
457,164
|
Please
inquire for additional probes and sensors |
AR72022 |
|
ET016020/350001 |
|
OPTIONAL
GENERAL PURPOSE TEMPERATURE PROBE
FOR Smart Reader Plus Data Loggers |
|
Yes |
|
174,420
|
Please
inquire for additional probes and sensors |
AR72023 |
|
ET-004 |
|
OPTIONAL
LOW TEMPERATURE PENETRATION PROBE (35-0000)
FOR Smart Reader Plus Data Loggers |
|
Yes |
|
328,644
|
Please
inquire for additional probes and sensors |
AR72024 |
|
ET-081-020 |
|
OPTIONAL
HIGH TEMPERATURE PROBE (35-0002)
FOR Smart Reader Plus Data Loggers |
|
Yes |
|
163,404
|
Please
inquire for additional probes and sensors |
AR72025 |
|
ET-086-020 |
|
OPTIONAL
OVEN TEMPERATURE PROBE (35-0003)
FOR Smart Reader Plus Data Loggers |
|
Yes |
|
163,404
|
Please
inquire for additional probes and sensors |
AR72031 |
|
A70FL |
|
OPTIONAL
MULTI-RANGE CLAMP-ON PROBE 60Hz VERSION
(35-0005) FOR Smart Reader Plus Data Loggers |
|
Yes |
|
291,924
|
Please
inquire for additional probes and sensors |
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|