LB02081977 HYPERLGGR SYSTM BASE
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : DAVIS
    ¡¤ ÆǸŰ¡°Ý : ¿ø
    ¡¤ Æ÷ ÀÎ Æ® : Á¡
    ¡¤ ¼ö ·® : °³


¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)
The HyperLogger Datalogger meets all your remote site and plant floor data collection and alarming needs.

HyperWare¢â for Windows¢â is simply powerful PC software providing everything needed for setup of the HyperLogger through collecting and plotting data. Use HyperWare for programming the HyperLogger, communicating between the HyperLogger and the PC, graphic data display, and real-time tracking. With HyperWare¢â for Windows, you are up and running immediately, benefiting from the standard Windows mouse and keyboard User interface as well as printer and communications equipment already installed for your other Windows applications.

HyperWare¢â for Windows includes:

HyperComm¢â visual communications via RS-232, modem or ethernet. Re-program, check status, download data, and control the Logger all via serial link.

HyperNet¢â intuitive, visual programming of the HyperLogger. Unlimited flexibility with unparalleled simplicity--and no programming languages required.

HyperPlot¢â graphic data display. Plot, analyze, print and export to other Windows applications.

HyperTrack¢â real-time data display. Monitor site data and performance via modem, or use for intelligent real-time data acquisition in the lab, all while the HyperLogger is logging data.

 
Features
  • Expandable to 24 analog/48 digital inputs
  • 150 Analog samples per second
  • Multi-function interface modules for VDC, VAC, thermocouples, RTD¡¯s, resistance, digital and Isolated Analog inputs available
  • 13 Bit ADC (12 bit-bipolar)
  • 5 Alarm outputs standard
  • Removable PCMCIA memory option
  • Battery or external power operation
  • Weatherproof enclosure standard
  • Modem, EtherNet, RF modem and cellular communications methods
  • HyperWare software included for: communications, icon-based programming, real-time trending, post processing and graphing
  • Excel and ASCII file format output
  • Systems supplied complete with software, manual, cables and batteries
 
More Features
  • Build HyperLogger programs visually via drag and drop icons
  • Programmable intelligent logging strategies
  • Unlimited programming flexibility
  • Zoomable graphic data display
  • BMP Plot outputs for other Windows applications
  • Full modem, RF Modem, EtherNet Support
  • Real-Time data display and tracking modes
 
SPECIFICATIONS

Parameter

Sampling Speed 150S/Sec - Max
Sample Capacity 40,000 std. 600,000 optionalwith PCMCIA card
Power Battery or 10-16VDC ext (3 wks logging on batteries)
Interface Module Ports 6
Thermocouples   Accuracy
(LB02081978 module) J, K, E, T types  1.2¡ÆC (CJC and curve)
R, S types  5¡ÆC (CJC and curve)
VDC (LB02081978 module) ¡¾20mV to ¡¾30VDC (11 ranges) ¡¾0.3% fs
ADC (LB02081978 module) ¡¾200¥ìA to ¡¾22mA ¡¾0.3% fs
Frequency (LB02081979 module) 5Hz-30kHz ¡¾5% +1 count
Count (LB02081979 module)   

0 count error
20KHz max input

RTD (100 or 1000 ohm) (LB02081980) -200¡ÆC to 450¡ÆC range 0.4¡ÆC
0.5¡ÆC
Resistance (LB02081980) 0 to 400,000¥Ø (12 ranges) 0.5% fs
Analog Resolution 13 bits
LB020819811 Fully isolated 18 bit, thermocouple, VDC, ADC
Enclosure Lockable, weatherproof NEMA 4X
Size 10.5" x 14" x 6.5"
Weight 10 lb
Operating Temperature -10¡ÆC to 60¡ÆC
Warranty 1 year
CAT NO. MODEL DEscRIPTION AVAIL PRICE
LB02081977   HL-1   HYPERLGGR SYSTM BASE W/WIND. & HLIM-1   Yes   4,553,280
LB02081978   HLIM-1   OPTIONAL ANALOG INTERFACE MODULE FOR Portable Datalogging System   Yes   633,420

 

LB02081979   HLIM-2   OPTIONAL DIGITAL INTERFACE MODULE FOR Portable Datalogging System   Yes   725,220

 

LB02081980   HLIM-4   OPTIONAL RESISTANCE INTERFACE MODULE FOR Portable Datalogging System   Yes   633,420

 

LB020819811   HLIM-7   OPTIONAL ANALOG INTERFACE MODULE FOR Portable Datalogging System   Yes   633,420

 

LB02081981   HLIM-8   OPTIONAL DIGITAL I/O INTERFACE MODULE FOR Portable Datalogging System   Yes   633,420

 

LB02081982   HLIM-5   OPTIONAL PCMCIA INTERFACE MODULE FOR Portable Datalogging System   Yes   302,940

 

LB02081983   MM-14.4   OPTIONAL 14.4 KBAUD MODEL MODULE FOR Portable Datalogging System   Yes   459,000

 

LB02081984   MC-200   OPTIONAL PCMCIA MEMORY CARD (2 MEG) FOR Portable Datalogging System   Yes   459,000

 

LB02081985   PD-1   OPTIONAL PCMCIA DRIVE FOR Portable Datalogging System   Yes   541,620
LB020819861   PSM-2   OPTIONAL Door mounted regulated sensor power supply FOR Portable Datalogging System   Yes   321,300

 

¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ.
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
DAVIS Á¾ÇÕ °èÃø±â - Çѱ¹´ë¸®Á¡ ÄÚ¸°½º°è±â(ÁÖ)
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ