ÀÚµ¿·Î±×ÀÎ
 

ÇöÀçÀ§Ä¡ : Home > ¿­·ù°è, ¿­·®°è

 
1341
    ¡¤ °í°´¼±È£µµ :
    ¡¤ Á¦Á¶»ç : PARR
    ¡¤ ÆǸŰ¡°Ý : ÀüÈ­¹®ÀÇ

¡á
ȸ¿øÀÌ µÇ½Ã¸é °¡°Ýº¯µ¿Á¤º¸, ½ÅÁ¦Ç°, ƯÆÇÁ¦Ç°, ±â¼úÁ¤º¸µî ´Ù¾çÇÑ
´º½ºÁ¤º¸¸¦ º¸³»µå¸³´Ï´Ù.
¡á
¹è¼ÛÀº Æò±Õ 2~3ÀÏÁ¤µµ ¿¹»óµË´Ï´Ù.
                    (0)                     (0)                     (0)

 

1.
                                                                                                                            Parr»ç¿¡¼­ 80³â µ¿¾È Á¦ÀÛÇØ¿Â °¡Àå ±âº»ÀûÀÎ ¹æ½ÄÀÇ °³¼±µÈ ¿­·®°è

 



2.°íü, ¾×ü µî ¿¬¼Ò¿­ ÃøÁ¤ÀÇ ¸ðµç ½Ã·á Àû¿ë °¡´É

 



3.°¡Àå Àú·ÅÇÏ°í ´Ü¼øÇÑ Çü½Ä

 

4.¼ö ºÐ³» ¼³Ä¡ ¹× ¿îÀü, »ç¿ëÇÏÁö ¾ÊÀ» °æ¿ì ºÐÇØ º¸°ü ¿ëÀÌ

 

5.¿­ ÃøÁ¤ ±³Àç·Î ÃÖÀûÀÇ ¾ÈÀüÇÑ ºÐ¼®

 

6.Jacket ¿Âµµ°¡ Á¶Á¤µÇÁö ¾Ê´Â ´Ü¼øÇÑ ¼³°è

 

7.1ȸ ºÐ¼® ½Ã 40~50ºÐ ¼Ò¿ä

 


8. 19~35µµ ¼öÀº ¿Âµµ°è »ç¿ë ½Ã ÀçÇö¼º 0.3% À̳»

 


9. 19~35µµ ¼öÀº¿Âµµ°è 0.02µµ ´«±Ý, È®´ë°æ »ç¿ë ½Ã ÃÖ´ë 0.002µµ °¡´É

 



A RELIABLE OXYGEN BOMB CALORIMETER IN A PLAIN INSULATED JACKET FOR OCCASIONAL CALORIFIC TESTS

The 1341 Calorimeter is an improved version of a plain, static jacket, oxygen bomb calorimeter that has been made by Parr for more than eighty years. It is a reliable calorimeter that can be used for the same broad range of solid and liquid combustible samples as the 1266, 1271, 1281 and 1356 models. Its modest cost and simple design recommend it primarily for users whose work load does not justify the purchase of an automatic model. The calorimeter requires no permanent connections. It can be set up and ready to operate in a few minutes and, when not in use, can be disassembled easily and stores on a shelf.

MANY APPLICATIONS

The calorific value of any solid or liquid material that can be burned safely in an oxygen bomb can be determined in the 1341 Calorimeter. It is also an excellent instrument for teaching heat measurement techniques in a student laboratory since it provides all of the instrumentation needed for such tests, but with each element in the system reduced to fundamental forms. Although commonly called a 'plain' calorimeter because of its simple design, technically this is a static jacket instrument which operates at or near room temperature with no provision for controlling the jacket temperature. Compensation for any heat loss (or gain) during a test is made by applying a correction computed from heat leak measurements taken before and after each test. As a general rule, about 10 or 12 tests can be completed in an 8-hour day, whereas up to 75 tests can be run in the same period in a Parr automatic model.

GOOD REPEATABILITY

Good repeatability can be obtained with the 1341 Calorimeter provided that the temperature rise and heat leak corrections are measured and applied carefully. Using the 19-35¡ÆC thermometer supplied with the instrument, standard deviations in a series of tests with a uniform sample such as benzoic acid should not exceed 0.3%. This repeatability can be improved by substituting a shorter range thermometer (Parr 1621 or 1623), or reduced to 0.2% by using the Parr 1672 Electronic Thermometer.

QUALITY CONSTRUCTION

There has been no compromise with quality in selecting components for the moderately priced, 1341 Calorimeter. It is equipped with the same 1108 Oxygen Bomb furnished with the 1266 Isoperibol Calorimeter. An alternate 1108CL bomb with superior resistance to chlorine and halogen acids is available for tests involving waste materials and chlorinated solvents. The molded double wall jacket provides a simple yet effective insulating system that restricts heat flow between the calorimeter and its surroundings. Temperature readings are taken with a 1604 Calorimetric Thermometer with a range from 19-35¡ÆC in .02¡Æ subdivisions. Readings can be estimated to the nearest .002¡Æ using the clip-on reading lens furnished with the instrument.

ORDERING GUIDE

1341 PLAIN CALORIMETER

The 1341 Calorimeter is furnished with an 1825 Oxygen Filling Connection, six fuel capsules, fuse wire for 1500 tests and support stands for the bomb head and calorimeter cover, also a vial of benzoic acid pellets for standardizing the calorimeter and complete operating instructions.

ACCESSORIES

The 2901 Ignition Unit is offered to provide low voltage electrical current to fire the oxygen bomb. An alternate ignition unit, 2902, is offered for use with calorimeters equipped with the 1672 Calorimetric Thermometer. The 2902 includes provisions for automatically firing the bomb under the control of the 1672 Thermometer/Controller.

The user must select the appropriate ignition unit for his installation and order it separately.

1341EB Plain oxygen bomb calorimeter with 1108 oxygen bomb, 115V 50/60 Hz
1341EE Plain oxygen bomb calorimeter with 1108 oxygen bomb, 230V 50/60Hz
1341CLEB Plain oxygen bomb calorimeter with 1108CL oxygen bomb for chlorine service, 115V 50/60Hz
1341CLEE Plain oxygen bomb calorimeter with 1108CL oxygen bomb for chlorine service, 230V 50/60Hz
2901EB Ignition unit, 115V 50/60Hz
2901EE Ignition unit, 230V 50/60Hz
1349 Spare parts kit for 1341 calorimeter

 
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ Æò°¡Á¡¼ö
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù.
 
* ÀÌ »óÇ°À» »ç¿ëÇØ º¸¼Ì´Ù¸é »ç¿ëÈı⸦ ½á ÁֽʽÿÀ.
¹øÈ£ Á¦¸ñ ÀÛ¼ºÀÚ ÀÛ¼ºÀÏ ´äº¯
1 ¿­·®°è °ßÀû¹®ÀÇÇÕ´Ï´Ù. ÇÏ»ó¿í 13-10-10 12:06
 
* ÀÌ »óÇ°¿¡ ´ëÇÑ ±Ã±ÝÇÑ »çÇ×ÀÌ ÀÖÀ¸½Å ºÐÀº Áú¹®ÇØ ÁֽʽÿÀ.
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù.
 
ȸ»ç¼Ò°³ | ¼­ºñ½ºÀÌ¿ë¾à°ü | °³ÀÎÁ¤º¸Ãë±Þ¹æħ
ÁÖ¼Ò : °æ±âµµ ¼º³²½Ã Áß¿ø±¸ µÐÃÌ´ë·Î 474, 708È£ (»ó´ë¿øµ¿ ¼±ÅؽÃƼ1)
Tel : 031-777-1588 / Fax : 031-777-1587 / °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : °ü¸®ÀÚ
»ç¾÷ÀÚ µî·Ï¹øÈ£ : 116-81-31753 / Åë½ÅÆǸž÷½Å°í : 2005-°æ±â¼º³²-0886È£
´ëÇ¥ÀÚ : È«¿µÈ­ / ¿î¿µÀÚ : À±»ó¹Ì
»óÈ£ : ÁÖ½Äȸ»ç ÄÚ¸°½º / Copyright ¨Ï 2002. All Rights Reserved.
°¡ÀÔ»ç½ÇÈ®ÀÎ