The BA Series of
infrared thermometers are engineered specifically for use on the
production line to measure moving objects quickly and accurately from a
safe distance. They measure targets within a temperature range of 32¡ÆF
- 932¡ÆF (0¡ÆC - 500¡ÆC) with a 500 millisecond response, at a ¡¾1%
level of precision.
A built-in coaxial
laser marker easily targets objects, with a 30mm diameter filed of view.
It has a 1¡Æ resolution on its digital display, and a 0.2¡Æ output
resolution. Temperature scale if ¡ÆF/¡ÆC switchable.
One of its most
unique features is the E-TEACH function for automatic adjustment of the
emissivity ratio. The BA Series thermometers have two choices of analog
output: TV-type (1mV/¡ÆC) which connects to such devices as a panel
meter, or TA-type (4-20mA), for long distance transmissions. An optional
air purge collar adapts this unit to dusty environments.
Applications range
from manufacturing of food, metal, glass, ceramics, rubber, synthetic
resin, to medical, petro-chemical, automotive, electrical and industrial
uses.
|
|
SPECIFICATIONS
|
DE499109
|
DE499108
|
DE499111
|
DE49970
|
Measuring Range |
0
to 500¡ÆC (display -20 to 520¡ÆC)
|
Field of View |
©ª
6/200mm
|
©ª
30/1000mm
|
Optics |
Silicon
lens
|
Sensing Element |
Thermopile/8
to 14 ¥ìm
|
Response Time |
500ms/90%
|
Measuring Accuracy |
¡¾1%
of reading value or ¡¾2¡ÆC, whichever is larger (¥å = 1.0)
|
Repeatability |
¡¾1¡ÆC
of reading value
|
Display Resolution |
1¡ÆC
|
Analog Output |
1
mV/¡ÆC
|
4-20
mA
|
1
mV/¡ÆC
|
4-20
mA
|
Output Resolution |
0.2¡ÆC
|
Sighting Method |
Coaxial
laser marker (Class 2)
|
Emissivity Ratio (
¥å) |
Adjustment
0.10 to 1.20 (0.01 / 1 step)
|
Power
Source/Consumption Current |
DC12
to 24V ¡¾ 10% • 150 mA
|
Ambient Temperature |
0
to 50¡ÆC
|
Ambient Humidity |
35
to 85% RH (without dew condensation)
|
Storage Temperature |
-10
to 60¡ÆC
|
Vibration
Resistance |
3G
(20 to 50Hz according to JIS CO911)
|
Water Resistance |
IP65
|
Materials |
Ring
case: glass - containing PBT, Rear cover: PC
|
Weight |
350
g
|
Standard
Accessories: attachment fittings x 1, attachment screw (M4) x 2 |
*The
laser marker is aimed at the center of t;he measuring area. The laser
has a 90% optical efficiency rate. The size of the object to be measured
must be sufficiently bigger than the measuring diameter. |
CAT
NO. |
|
MODEL |
|
DEscRIPTION |
|
AVAIL |
|
PRICE |
DE499108 |
|
BA-06TA |
|
Infrared
thermometer w/LCD display (15201) 4-20mA, ©ª 6/200mm field of view |
|
Yes |
|
1,551,420
|
DE499109 |
|
BA-06TV |
|
Infrared
thermometer w/LCD display (15202) 1mV/¡ÆC, ©ª 6/200mm field of view |
|
Yes |
|
1,606,500
|
DE49970 |
|
BA-30TA |
|
Infrared
thermometer w/LCD display (15203) 4-20mA, ©ª 30/1000mm field of view |
|
Yes |
|
1,606,500
|
DE499111 |
|
BA-30TV |
|
Infrared
thermometer w/LCD display (15204) 1mV/¡ÆC, ©ª 30/1000mm field of view |
|
Yes |
|
1,606,500
|
DE499112 |
|
15205 |
|
OPTIONAL
Air purge collar FOR
On-Line Infrared Thermometer |
|
Yes |
|
211,140
|
| |
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
Æò°¡Á¡¼ö |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ »ç¿ëÈıⰡ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
»ç¿ëÈı⸦ ÀÛ¼ºÇØ ÁÖ½Ã¸é ´Ù¸¥ ºÐµé²² ¸¹Àº µµ¿òÀÌ µË´Ï´Ù. |
|
|
|
|
|
|
| |
|
¹øÈ£ |
Á¦¸ñ |
ÀÛ¼ºÀÚ |
ÀÛ¼ºÀÏ |
´äº¯ |
|
|
|
ÀÌ »óÇ°¿¡ ´ëÇÑ Áú¹®ÀÌ ¾ÆÁ÷ ¾ø½À´Ï´Ù.
±Ã±ÝÇϽŠ»çÇ×Àº ÀÌ°÷¿¡ Áú¹®ÇÏ¿© ÁֽʽÿÀ. |
|
|
|
|
|
|
| |
ÀÌ »óÇ°°ú °ü·ÃµÈ »óÇ°ÀÌ ¾ø½À´Ï´Ù. | |
|
|